FBO DAILY - FEDBIZOPPS ISSUE OF OCTOBER 16, 2016 FBO #5441
DOCUMENT

Y -- Replace Piping & Install Leak Detection for UST-VA256-16-AP-9253 - Attachment

Notice Date
10/14/2016
 
Notice Type
Attachment
 
NAICS
236220 — Commercial and Institutional Building Construction
 
Contracting Office
Department of Veterans Affairs;Chief, A&MM (90C/NLR);Central Arkansas Veterans HCS;2200 Fort Roots Drive, Bldg 41, Room 200;North Little Rock AR 72114 1706
 
Solicitation Number
VA25617B0001
 
Response Due
12/14/2016
 
Archive Date
2/12/2017
 
Point of Contact
Renardo C Hollowell
 
E-Mail Address
7-1338<br
 
Small Business Set-Aside
Service-Disabled Veteran-Owned Small Business
 
Description
This Pre-solicitation Notice is established to inform SERVICE DISABLED VETERAN-OWNED SMALL BUSINESSES of the following requirement: The G.V. (Sonny) Montgomery VA Medical Center (GVMVAMC), located in Jackson, MS, has a requirement titled "Replace Piping and Install Tank and Piping Leak Detection For Underground Storage Tank". The government's intent is to issue a solicitation to award a single contract. This acquisition will be solicited pursuant to the Veterans' First Public Law 109-461 as a 100% Service-Disabled Veteran-Owned Small Business Set-Aside (SDVOSB). Additionally, this acquisition will be awarded in accordance with FAR 14.408-1(a) to the responsible bidder whose bid, conforming to the Invitation for Bid, will be most advantageous to the Government, considering only price and the price-related factors. Please do not send questions regarding this announcement, as it is only a Pre-Solicitation Notice. Questions will be accepted only after the solicitation has been published. A Firm-Fixed Price construction contract award is anticipated. Contractor shall furnish all supervision, labor, material, tools, transportation and equipment to provide the replacement of piping and install tank and piping leak detection services associated with an active 15,000 gallon underground tank in conjunction with the Statement of Work (SOW). The location of work to be performed is the G.V. (Sonny) Montgomery VAMC, located at 1500 Woodrow Wilson Ave., Jackson MS 39216. The period of performance will be 90 calendar days from the Notice to Proceed. The anticipated solicitation is projected to post on or about November 12, 2016, on this website. Hard copies will not be mailed. The solicitation will be issued as an Invitation for Bid (IFB). INTERESTED PARTIES ARE STRONGLY ENCOURAGED TO REGISTER TO RECEIVE NOTIFICATION OF ACTIONS INCLUDING POSTING OF THE SOLICITATION AND ANY AMENDMENTS. ADDITIONALLY, BIDDERS ARE ADVISED TO CHECK THE SITE FREQUENTLY AS THEY ARE RESPONSIBLE FOR OBTAINING AMENDMENTS TO THE SOLICITATION NOTICE. The following is an abbreviated reference of Statement of Work and does not address the entire requirement: 1.The Contractor shall provide all personnel, equipment, supplies, facilities, transportation, tools, materials, supervision, and other items and non-personal services necessary to replace all piping associated with the 15,000 gallon underground fuel tank. a.Tank is considered a regulated underground storage tank by the U.S. EPA and the Mississippi Department of Environmental Quality (MDEQ). All work must be done in accordance with U.S. EPA and MDEQ Underground Storage Tank regulations. b.In addition to removing all old underground piping in active use, Contractor must remove ALL old piping associated with the Underground Storage Tank System including piping that is out of service or no longer functional. Contractor must also remove all electrical wiring, conduit, etc. that is no longer in service and provide for its proper disposal or off ­ site recycling. Removed items except impress current cathodic protection rectifier noted below CANNOT be reused on-site. Contractor must provide for proper disposal or off ­ site recycling of all removed piping, conduit, wiring, equipment, etc. in accordance with applicable U.S. EPA, MDEQ, and U.S. DOT regulations. c.Contractor is responsible for all notifications to MDEQ and other agencies that are necessary for replacing the piping including any costs associated with filing such notifications. d.Contractor is responsible for the proper reuse or disposal of fill material generated as result of removing and replacing the piping in accordance with current MDEQ protocols including any sampling required. Documentation of appropriate disposal or fitness for reuse must be provided if such documentation is required to be generated. A 60 day bid acceptance period will be required. A Bid bond must be submitted with the bid. Performance and Payment bonds will be required from the contractor receiving award. A pre-bid conference will be held at a date, time, and location to be provided in the solicitation announcement. The magnitude of construction is between $25,000 and $100,000. The North American Industrial Classification Standard (NAICS) code assigned to this construction project is 236220 with a small business size standard of $36.5 million. Bidders shall be registered at the Vendor Information Pages at www.vip.vetbiz.gov, in System for Award Management (SAM) database at www.sam.gov, and have completed online Representations and Certifications prior to the solicitation due date. Bidders shall be registered with the NAICS code 236220 assigned to this acquisition.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/VA/VACAHCS598/VACAHCS598/VA25617B0001/listing.html)
 
Document(s)
Attachment
 
File Name: VA256-17-B-0001 VA256-17-B-0001_1.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=3056568&FileName=VA256-17-B-0001-000.docx)
Link: https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=3056568&FileName=VA256-17-B-0001-000.docx

 
Note: If links are broken, refer to Point of Contact above or contact the FBO Help Desk at 877-472-3779.
 
Place of Performance
Address: Department of Veteran Affairs;G.V.(Sonny)Montgomery Medical Center;1500 E. Woodrow Wilson Ave;Jackson, MS
Zip Code: 39216
 
Record
SN04304442-W 20161016/161014233614-16d082d2a7dfbe00c9b55e423982f33d (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.