DOCUMENT
65 -- Humphrey Matrix VA250-17-Q-0058 - Attachment
- Notice Date
- 11/10/2016
- Notice Type
- Attachment
- NAICS
- 541519
— Other Computer Related Services
- Contracting Office
- Department of Veterans Affairs;Dayton VA Medical Center;3140 Governor ™s Place Blvd. Suite 210;Kettering OH 45409-1337
- ZIP Code
- 45409-1337
- Solicitation Number
- VA25017Q0058
- Archive Date
- 12/10/2016
- Point of Contact
- Chris Rapp
- Small Business Set-Aside
- Service-Disabled Veteran-Owned Small Business
- Description
- This Sources Sought Notice is for informational and planning purposes only and shall not be construed as a solicitation or as an obligation or commitment by the Government at this time. This notice is intended strictly for market research. The purpose of this Sources Sought notice is to determine interest and capability of potential qualifications of Small Businesses, including 8(a), Hub Zone and Service Disabled Veteran-Owned firms relative to the North American Industry Classification Code (NAICS) 339114.The Department of Veteran's Affairs is seeking small business manufacturer or distributors of small business manufacturers, of functionally equivalent equipment to all the following: This request is for the purchase of 1 Zeiss Matrix 800 with printer and chin rest Salient Characteristics 1)Visual Field threshold testing of the center and periphery using frequency doubling technology to provide the lowest retest variability for testing traumatic brain injury patients 2) Test time less than 5 minutes per eye 3) Test locations the same as standard automated perimeters so that the results can be compared to other tests in the same patient 4) No eyeglass correction needed for testing, unlike other non-frequency doubling perimeters 5) Data results must be provided in electronic tabular form for exporting to a spreadsheet. Specifications Test Specifications Maximum temporal range (degrees) 30 Stimulus duration 300ms Visual field testing distance Infinity Background illumination 100 cd/m2 Threshold test libraries FDT Full Threshold: 24-2, 30-2, N-30, 10-2, Macula Threshold test strategy MOBS, ZEST Screening test libraries FDT Supra-threshold: N-30, 24-2 Fixation control Video eye monitoring, Heijl Krakau fixation method, Alternative fixation targets Operator interface LCD, keyboard Stimulus Frequency doubled sinusoidal gratings Stimulus sizes 2 °, 5 °, 10 ° Printer Native generic PCL 3, PCL 5 and postscript support for local, shared and Network printers Test storage User-defined Software features Glaucoma Hemifield Test (GHT), Serial Field Overview, Networking, FORUM Connectivity, DICOM Connectivity Data storage, retrieval and analysis 40 GB hard drive, USB, CD-R/W drive Dimensions Height 17'' (43 cm) Width 12'' (30 cm) Depth 22'' (56 cm) Weight 30 lbs (14 kg) Electrical requirements 100-240 V, ~50/60 Hz, 200 VA max Standards Meets UL, CSA, and CE standards THIS IS NOT A SOLICITATION AND DOES NOT OBLIGATE THE GOVERNMENT TO ISSUE A SOLICITATION. Please be advised that the Government will not pay for any information submitted under this announcement. The applicable North American Classification System (NAICS) Code for this requirement is 339114 (Dental Equipment and Supplies Manufacturing). Responses are to be submitted by e-mail to Christopher.Rapp2@va.gov. No later than 11/10/2016 @ 9 A.M. Email should contain the following information: Name of firm, Socio-Economic category of the firm (SDVOSB, VOSB, 8A, HUBZONE or SMALL BUSINESS), complete address, phone & fax number of contact.
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/VA/DaVAMC552/DaVAMC552/VA25017Q0058/listing.html)
- Document(s)
- Attachment
- File Name: VA250-17-Q-0058 VA250-17-Q-0058.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=3103664&FileName=VA250-17-Q-0058-000.docx)
- Link: https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=3103664&FileName=VA250-17-Q-0058-000.docx
- Note: If links are broken, refer to Point of Contact above or contact the FBO Help Desk at 877-472-3779.
- File Name: VA250-17-Q-0058 VA250-17-Q-0058.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=3103664&FileName=VA250-17-Q-0058-000.docx)
- Place of Performance
- Address: Louis Stokes VA Medical Center;10701 East Boulevard;Cleveland, OH
- Zip Code: 44106-1702
- Zip Code: 44106-1702
- Record
- SN04325716-W 20161112/161110234141-34763745d4063a197ac44941d74c258c (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |