Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY - FEDBIZOPPS ISSUE OF DECEMBER 09, 2016 FBO #5495
SOLICITATION NOTICE

Y -- CLR043 Design and Construct Fire Station

Notice Date
12/7/2016
 
Notice Type
Presolicitation
 
NAICS
236220 — Commercial and Institutional Building Construction
 
Contracting Office
Department of the Army, U.S. Army Corps of Engineers, USACE District, Alaska, ATTN: CEPOA-CT, P. O. Box 6898, JBER, Alaska, 99506-6898, United States
 
ZIP Code
99506-6898
 
Solicitation Number
W911KB-17-R-0021
 
Archive Date
2/7/2017
 
Point of Contact
Julie C. McLaughlin, Phone: 9077532894, Theresa M Afrank, Phone: 907-753-2739
 
E-Mail Address
julie.c.mclaughlin@usace.army.mil, theresa.m.afrank@usace.army.mil
(julie.c.mclaughlin@usace.army.mil, theresa.m.afrank@usace.army.mil)
 
Small Business Set-Aside
Competitive 8(a)
 
Description
CONTRACT INFORMATION: This is a pre-solicitation notice for a two-phase, competitive 8(a) Proposal (RFP) to Design and Construct a Fire Station at Clear AFS, AK (CLR043). Response date of 23 January 2017 is based on issuance of the RFP on or about 22 December 2016. The procurement will be conducted using two-phase source selection procedures and the award will be based on the best overall value to the Government considering the non-price factors described in the RFP, and price. The Government will evaluate Phase 1 proposals in accordance with the evaluation rating systems outlined in the Phase 1 Design-Build selection procedures of the RFP. Those offerors short-listed in Phase 1 will be invited to submit a Phase 2 proposal. The Phase 2 evaluation will be conducted in accordance with evaluation criteria specified in the RFP for Phase 2, FAR Part 15, and will utilize the Tradeoff Process described in FAR 15.101-1. Any resulting contract will be firm fixed price. The anticipated Notice to Proceed date will be third quarter 2017 with a period of performance of 732 calendar days. Offerors are advised that a contract resulting from this solicitation is subject to the availability of funds and may be cancelled or revised at any time during the solicitation, selection, evaluation, negotiation and final award. Should Congress not appropriate funds, the solicitation will be cancelled. If the project is cancelled, all proposal preparation costs will be borne by the offeror. All contractors are advised that they must be registered in the System of Award Management (SAM) (https://www.sam.gov/). Joint ventures must also be registered in SAM as a joint venture. We advise contractors to begin this process when they prepare their proposal in order to ensure this registration is in place should they be selected for the award. Lack of registration in the SAM database will make an offeror ineligible for award. PROJECT INFORMATION: Design and Construct fire station facility consisting of a reinforced concrete foundation with slab on grade, concrete masonry walls with an exterior insulation finish system and a standing seam metal roof. Project includes four (4) drive-through vehicle bays, alarm and communications room, fire detection/suppression systems and all other standard fire department functions. Facility will be designed as a permanent construction in accordance with DoD Unified Facilities Criteria (UFC) 1-200-01, General Building Requirements and UFC 1-200-02, High Performance and Sustainable Building Requirement. Comply with DoD minimum Antiterrorism Standards for buildings per UFC 4-010-01. Potable water will be provided through a new buried concrete utilidor. Sanitary waste will be provided with lift station connected to the existing sewage system. Buried electrical service with a pad-mounted transformer will be provided. Local backup power is also included with an arctic grade generator. Anticipated contract cost limitation is $17,122,000.00. SELECTION CRITERIA: This acquisition will evaluate offerors considering the following factors: For Phase 1: Experience, Past Performance (Confidence Assessment), Organization and Management Approach. For Phase 2: Design - Construction Narrative and Drawings, Proposed Summary Schedule, Phase 1 Proposal Roll-Up Rating, Price and Required Pre-Award Information The overall evaluation of the non-price factors is considered significantly more important than price. OBTAINING THE SOLICITATION: The solicitation, including plans and specifications, will be available electronically from FedBizOpps website (www.fbo.gov). On the FedBizOpps website, vendors will need to utilize the Vendor Opportunities Search function and enter this solicitation number to Search by Solicitation/Award Number. The solicitation and any future amendments to the solicitation will be available for download via FedBizOpps website. All responsible firms may submit an offeror in the form and format of the solicitation which will be considered by the agency. All notifications of changes to this solicitation shall be made through the internet only. It is the offeror's responsibility to check for any posted changes to this solicitation.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/USA/COE/DACA85/W911KB-17-R-0021/listing.html)
 
Place of Performance
Address: CLEAR AFS, Anderson, Alaska, 99704, United States
Zip Code: 99704
 
Record
SN04345652-W 20161209/161207234214-79e36bece75fafcadc1adf2bb266be8d (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.