Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY - FEDBIZOPPS ISSUE OF JANUARY 06, 2017 FBO #5523
DOCUMENT

65 -- Washer/Disinfector-Steam Heat-Installation included Questions and answers - Attachment

Notice Date
1/4/2017
 
Notice Type
Attachment
 
NAICS
339112 — Surgical and Medical Instrument Manufacturing
 
Contracting Office
Department of Veterans Affairs;Network Contracting Office 9;1639 Medical Center Parkway;Suite 400;Murfreesboro TN 37129
 
ZIP Code
37129
 
Solicitation Number
VA24917N0190
 
Archive Date
1/19/2017
 
Point of Contact
Thomas Allman
 
E-Mail Address
5-6320<br
 
Small Business Set-Aside
N/A
 
Description
Sterilization project questions SPS Department and Mobile Unit when will site walks of the SPS Department be held?   Additionally, site walk for placement of Mobile Unit? Contracting will schedule site visit. This date will be in the RFQ when it is posted. Are CAD files available for SPS Department and potential sites for Mobile unit? CAD file available for department only. Engineering will be responsible to present CAD. What RO/DI system is in place and output capacity? RO in place but Engineering will define what type and output capacity. Can we be presented a list of all products to sterilized in the VPro Max? List is attached Would manual doors be acceptable if increased productivity is achieved? no Would automatic horizontal doors be acceptable if (40) trays per hour could be achieved? This cannot be determined without knowing the size required for horizontal doors or the size of the sterilizer. The sterilizers need to fit within the footprint of SPS. We have multiple sterilizer loads per day that require different parameters and we do not want to be limited on the amount of different loads we can run per shift. The requirement states three sterilizers are needed. Some Products on RFI are not in our product portfolio and specifications listed indicate one vendor.   Can an alternative product be presented? Alternative products may be presented as long as they meet the requirements stated in the SOW. Is there enough room on both sides of requested washers for closed loop automation? This will have to be determined based on CAD drawings and site walk findings. What is meant by combining Medivator and steam room together? We have a room within our decontamination room that houses our Medivator AERs that is used for endoscope high level disinfection as well as other HLD items. We would like a clean space created that would combine the Medivator room with extra rooms that we have available in order to be compliant with Joint Commission, VHA, and AAMI standards. Space will be annotated on CAD drawings and site walk. What is meant by the term reusable medical equipment ?   Is this instruments only or does it include other products? Reusable medical equipment includes Instrumentation and endoscopes (that are high level disinfected and/or sterilized) following manufacturers instructions. For the mobile unit will we be working directly with VA or with a contractor? The mobile unit will be VA staffed. The vendor will be responsible for installation and de-installation of Mobile Unit. The use of Mobile Unit will be determined based on the length of the project to renovate SPS and the installation of equipment. For the mobile unit where are the specifications for the mobile unit coming from?   Is this part of a standard SPS renovation package? The specifications are based on market research as well as the standards for which SPS must be in compliance with (referring to same requirements from Joint Commission, AAMI, VHA Standards, and Oct 2015 VA SPS Design Guide)
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/VA/NaVAMC/VAMCCO80220/VA24917N0190/listing.html)
 
Document(s)
Attachment
 
File Name: VA249-17-N-0190 VA249-17-N-0190_1.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=3194032&FileName=VA249-17-N-0190-001.docx)
Link: https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=3194032&FileName=VA249-17-N-0190-001.docx

 
Note: If links are broken, refer to Point of Contact above or contact the FBO Help Desk at 877-472-3779.
 
Record
SN04362584-W 20170106/170104234113-408777bc0fdfc919d8915627a998ada2 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers