FBO DAILY - FEDBIZOPPS ISSUE OF JANUARY 08, 2017 FBO #5525
SOLICITATION NOTICE

L -- Calibration Services for a Whole Body Counting System

Notice Date
1/6/2017
 
Notice Type
Presolicitation
 
NAICS
541990 — All Other Professional, Scientific, and Technical Services
 
Contracting Office
Department of Health and Human Services, Food and Drug Administration, Office of Acquisitions and Grants Services - Rockville, 5630 Fishers Lane, Room 2129, Rockville, Maryland, 20857-0001, United States
 
ZIP Code
20857-0001
 
Solicitation Number
FDA-17-1178389-SS
 
Archive Date
2/1/2017
 
Point of Contact
Tiffany R. Williamson,
 
E-Mail Address
tiffany.williamson@fda.hhs.gov
(tiffany.williamson@fda.hhs.gov)
 
Small Business Set-Aside
Total Small Business
 
Description
Notice to Small Businesses The purpose of this notice is to obtain information regarding the availability and capability of qualified small business concerns; 8(a), Woman-Owned Small Businesses (WOSB), Historically Underutilized Business Zone (HUBZone), Small Businesses, and Service-Disabled Veteran-owned Small Businesses (SDVOSB). The Food and Drug Administration intends to provide maximum practicable opportunities in its acquisitions to small businesses. The Food and Drug Administration (FDA) is conducting a market survey to assess the availability of small business firms as defined by NAICS code 541990 to provide calibration services for a Whole Body Counting System for the Radiation Safety Program. This notification is for market research purposes and does not constitute a commitment, implied or otherwise, that a procurement will be accomplished. FDA welcomes responses from all interested parties. FDA does not intend to make a selection decision or award a contract on the basis of responses nor otherwise pay for the preparation of any information submitted of FDA's use of such information. Acknowledgment of receipt of responses may not be made, nor will respondents be notified of the outcome of the FDA's review of the information received. Additionally, the FDA does not intend to hold discussions concerning this sources sought with any interested parties. However, FDA reserves the right to contact vendors if additional information is required. This is not an invitation for bid, request for proposal, or other solicitation, and in no way obligates the Food and Drug Administration (FDA) to award a contract. Background: The Food and Drug Administration's Winchester Engineering and Analytical Center (WEAC) is seeking calibration services for a Whole Body Counting System for the Radiation Safety Program. The calibrations require the use of the Bottle Mannikin Absorber Phantom (BOMAB), Livermore Lung, and American National Standards Institute (ANSI) neck phantom with corresponding radioactive sources. This will include shipping of the phantoms to/from the calibrator's chosen destinations. Description: The contractor shall provide calibration services for a Whole Body Counting System for the Radiation Safety Program. The specifications are as follows: • The WBC (whole body): o Energy calibration o Efficiency calibration utilizing a BOMAB (Eu-152 source) o Efficiency confirmation counts o Quality Control counts • The WBC (lung): o Energy calibration o Efficiency calibration utilizing the Livermore Lung Phantom with chest overlays using 5 different chest wall thicknesses. o Efficiency confirmation counts o Quality Control counts • The Thyroid Detectors as combined unit and as two separate units: o Energy calibration o Efficiency calibration utilizing an ANSI neck phantom and mixed gamma source o Efficiency confirmation counts o Quality Control counts Place of Performance: Calibration shall be on-site at the location listed below: Winchester Engineering & Analytical Center (WEAC) 109 Holton Street Winchester, MA 01890 General Instructions Contractors that believe they possess the ability to provide the required services must submit documentation of their ability to meet each of the characteristics listed above to the Contract Specialist (i.e. brochure, information on equipment that meets specifications, etc.) The capability statement must also include the organization name, type of business, DUNS number, point of contact name/telephone number/email address, applicable NAICS code, and current GSA Schedule if appropriate. If any specifications are highly restrictive, please provide that information to the Contract Specialist as well. Capability statements that do not provide sufficient information for assessment will be considered nonresponsive. When submitting the information, please reference the solicitation number FDA-17- 1178389-SS. Responses should be submitted via email to Tiffany Williamson at Tiffany.Williamson@fda.hhs.gov by 12:00 pm EST on 01/17/2017.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/HHS/FDA/DCASC/FDA-17-1178389-SS/listing.html)
 
Place of Performance
Address: Winchester Engineering & Analytical Center (WEAC), 109 Holton Street, Winchester, Massachusetts, 01890, United States
Zip Code: 01890
 
Record
SN04365621-W 20170108/170106234114-6f7a06905f51b420a2566301debc3d01 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.