DOCUMENT
65 -- Ultrasound Replacement Part - Attachment
- Notice Date
- 1/24/2017
- Notice Type
- Attachment
- NAICS
- 339112
— Surgical and Medical Instrument Manufacturing
- Contracting Office
- Department of Veterans Affairs;VISN/18PHX;777 E. Missouri, Suite 300;Phoenix AZ 85014
- ZIP Code
- 85014
- Solicitation Number
- VA25817Q0184
- Response Due
- 1/27/2017
- Archive Date
- 3/28/2017
- Point of Contact
- LOUIS R WADE
- E-Mail Address
-
5-4475<br
- Small Business Set-Aside
- N/A
- Description
- STATEMENT OF WORK (SOW) as of 18/NOV/2016 Contract Number: (completed by the CO at time of award) Task Order Number: (completed by the CO at time of award if a TO) IFCAP Tracking Number: B161028-003 Follow-on to Contract and Task Order Number: Not Applicable 1. Contracting Officer s Representative (COR). Name: Section: Address: 1501 San Pedro Drive SE Albuquerque, NM 8108-5153 Phone Number: Fax Number: E-Mail Address: 2. Contract Title. Offsite repair service for Philips CX50 ultrasound system The Manufacturer is Philips Medical System NA. The model is a CX50 ultrasound system S/N: SG11304072. The probe is a L12-3 linear. The Vendor ID# is: 58944842. The location is 1C128-41. The EE# is 66578. Philips CX50 ultrasound system has a need to replace the L12-3 linear array ultrasound probe is causing pixel artifact in the exam images. Philips CX50 ultrasound system 3. Background. Trouble call was placed to Biomed Imaging stating that the image had dots through. I went up and troubleshot problem with tech and found that the L12-3 has a group of faulty element and came to the conclusion that probe have to be replaced to resolve problem. I will order new probe. The probe is part of the Philips CX50 ultrasound system which is used to daily to assist in the diagnoses of patient exams. The exams preformed are interventional radiography which includes biopsies, fluid drain, and vascular procedures. The system is used for these proposes on a daily base. The Manufacturer is Philips Medical System NA. The model is a CX50 ultrasound system S/N: SG11304072. The probe is a L12-3 linear. The Vendor ID# is: 58944842. The location is 1C128-41. The EE# is 66578 4. Scope. Trouble call was placed to Biomed Imaging stating that the image had dots through. I went up and troubleshot problem with tech and found that the L12-3 has a group of faulty element and came to the conclusion that probe have to be replaced to resolve problem. I will order new probe. The probe is part of the Philips CX50 ultrasound system which is used to daily to assist in the diagnoses of patient exams. The exams preformed are interventional radiography which includes biopsies, fluid drain, and vascular procedures. The system is used for these proposes on a daily base. The Manufacturer is Philips Medical System NA. The model is a CX50 ultrasound system S/N: SG11304072. The probe is a L12-3 linear. The Vendor ID# is: 58944842. The location is 1C128-41. The EE# is 66578 6. Performance Monitoring The CX50 ultrasound system will be tested with the new probe to confirm that the probe is working properly. 7. Security Requirements The C&A requirements do not apply, and that a Security Accreditation Package is not required.
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/VA/PhVAMC/HMC/VA25817Q0184/listing.html)
- Document(s)
- Attachment
- File Name: VA258-17-Q-0184 VA258-17-Q-0184.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=3229108&FileName=VA258-17-Q-0184-000.docx)
- Link: https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=3229108&FileName=VA258-17-Q-0184-000.docx
- Note: If links are broken, refer to Point of Contact above or contact the FBO Help Desk at 877-472-3779.
- File Name: VA258-17-Q-0184 VA258-17-Q-0184.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=3229108&FileName=VA258-17-Q-0184-000.docx)
- Place of Performance
- Address: New Mexico VAHCS;1501 San Pedro Dr. SE;Albuquerque, NM
- Zip Code: 87108
- Zip Code: 87108
- Record
- SN04379153-W 20170126/170124234427-0a6d41f6911f672f9b652a330906cdb9 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |