Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY - FEDBIZOPPS ISSUE OF JANUARY 29, 2017 FBO #5546
DOCUMENT

66 -- Denver Activation RES EQ05 Centrifuges - PO# - Attachment

Notice Date
1/27/2017
 
Notice Type
Attachment
 
NAICS
333999 — All Other Miscellaneous General Purpose Machinery Manufacturing
 
Contracting Office
Department of Veterans Affairs;Program Contracting Activity Central;6150 Oak Tree Blvd, Suite 300;Independence OH 44131
 
ZIP Code
44131
 
Solicitation Number
VA70117Q0072
 
Response Due
2/1/2017
 
Archive Date
4/2/2017
 
Point of Contact
Grace Kelly-Burnsworth
 
E-Mail Address
7-8300
 
Small Business Set-Aside
Service-Disabled Veteran-Owned Small Business
 
Description
This is an amendment to a combined synopsis/solicitation for commercial items prepared in accordance with the format in Subpart 12.6. This amendment hereby revises the quote due date from 01-30-2017 at 3:00 PM EST to 02-01-2017 at 3:00 PM EST. In addition, this amendment revises CLIN 0005 from: CLIN0005 Centrifuge, Heavy Duty, Floor Model (JSN L1750.A) Quantity: 3 Beckman Coulter Avanti J-E OR EQUAL Specifications/Salient Characteristics The unit shall have a maximum speed of approximately 21,000 RPM The unit shall accommodate up to approximately 4 liters The unit shall have an operating temperature range of approximately -10 to 40oC The unit shall utilize CFC-free, non-ozone depleting refrigerant Approximate Dimensions and Power: Approximate Dimensions (Lid Closed): 25 W x 32 D x 36 H Power Requirements: 120V, 60 Hz Accessories/Configuration Options: No accessories specified To: CLIN0005 Ultracentrifuge (JSN L1770) Quantity: 3 Beckman Coulter Optima XPN 80 OR EQUAL Specifications/Salient Characteristics Handles tubes from 0.2ml to 3.5ml, Has a programmable memory for repeat of select runs and has selectable acceleration and deceleration rates. Operates in the range from 2-40 degrees C. Has a digital timer, Has electronic door locking mechanism. The maximum speed is approximately 90,000 RPM. Approximate Dimensions and Power: Approximate Dimensions: 37 W x 28 D x 48 H Power Requirements: 200-240V, 20A, 60 Hz Accessories/Configuration Options: No accessories specified. All other terms and conditions contained in the solicitation remain unchanged.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/VA/ISC/OISC/VA70117Q0072/listing.html)
 
Document(s)
Attachment
 
File Name: VA701-17-Q-0072 VA701-17-Q-0072.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=3238053&FileName=VA701-17-Q-0072-003.docx)
Link: https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=3238053&FileName=VA701-17-Q-0072-003.docx

 
Note: If links are broken, refer to Point of Contact above or contact the FBO Help Desk at 877-472-3779.
 
Place of Performance
Address: VA Eastern Colorado Health Care System;1700 N. Wheeling St.;Aurora CO
Zip Code: 80045
 
Record
SN04383505-W 20170129/170127234220-d45587a3701cc76edf5d847c4ca9be41 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.