Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY - FEDBIZOPPS ISSUE OF FEBRUARY 04, 2017 FBO #5552
DOCUMENT

66 -- PR# 629-17-2-7224-0266 Project Legacy, Sup Clinical Laboratory Reagent Water System PLMS, Clinical Laboratory Reagent Water (CLRW) - Attachment

Notice Date
2/2/2017
 
Notice Type
Attachment
 
NAICS
334516 — Analytical Laboratory Instrument Manufacturing
 
Contracting Office
Department of Veterans Affairs;Southeast Louisiana Veterans HCS;Network Contracting Office (NCO) 16;1555 Poydras Street, Ste. 1895;New Orleans LA 70112
 
ZIP Code
70112
 
Solicitation Number
VA25617Q0284
 
Response Due
2/13/2017
 
Archive Date
4/14/2017
 
Point of Contact
Department of Veterans Affaris
 
E-Mail Address
k
 
Small Business Set-Aside
Veteran-Owned Small Business
 
Description
The overall purpose of this SOW is to obtain and install Clinical Laboratory Reagent Water (CLRW) Systems at the Southeast Louisiana Veterans Health Care System (SLVHCS) for the Pathology and Laboratory Medicine Service 4th floor D&T building at 2400 Canal St., New Orleans, LA 70119. These systems are necessary to produce Clinical Laboratory Grade Water which is used to prepare reagents, clean instrument parts, dilution of patient samples, prepare instrument cleaning solutions and provide water for tissue sample processing. SALIENT CHARACTERISTICS Clinical Laboratory Reagent Water System QTY - 6 Specific/Salient Characteristics: The unit shall operate on routine tap water as the feed source. The unit shall operate on 110 VAC, 60 Hz electrical power. The unit shall be able to be placed on a counter top The unit shall not exceed 28 inches high by 28 inches wide by 20 inches deep The unit shall weigh less than 75 pounds. The unit shall produce Clinical Laboratory Reagent Water with the following characteristics: Resistance: 10 M /cm Bacteria: 1CFU/mL Particulate size: 0.22 µm The unit shall be able to provide >20liters of Clinical Laboratory Reagent Water per hour The unit hall have an on-board storage capacity of > 25 liters. The unit shall be fitted with a manual dispensing system. The unit shall have a pre-filters carbon/particulates. Routine daily maintenance shall be less than 5 minutes. Monthly maintenance shall be less than 10 minutes. Periodic maintenance (i.e.: bio-monthly/quarterly) shall be less than 20 minutes.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/VA/NOrVAMC/VAMCCO80220/VA25617Q0284/listing.html)
 
Document(s)
Attachment
 
File Name: VA256-17-Q-0284 VA256-17-Q-0284.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=3251196&FileName=VA256-17-Q-0284-000.docx)
Link: https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=3251196&FileName=VA256-17-Q-0284-000.docx

 
Note: If links are broken, refer to Point of Contact above or contact the FBO Help Desk at 877-472-3779.
 
Place of Performance
Address: Department of Veterans Affairs;Southeast Louisiana Veterans HCS;Pathology Laboratory Service;2400 Canal Street;New Orleans, LA
Zip Code: 70119
 
Record
SN04388824-W 20170204/170202234520-800eacde0a0555fbf188df2325e1ddbe (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.