SOURCES SOUGHT
Y -- Emergency Services Center (ESC) at Fort Hunter Liggett (FHL), CA
- Notice Date
- 2/6/2017
- Notice Type
- Sources Sought
- NAICS
- 236220
— Commercial and Institutional Building Construction
- Contracting Office
- Department of the Army, U.S. Army Corps of Engineers, USACE District, Louisville, Attn: CELRL-CT, PO Box 59, Louisville, Kentucky, 40201-0059, United States
- ZIP Code
- 40201-0059
- Solicitation Number
- W912QR-17-FHL-ESC
- Archive Date
- 3/7/2017
- Point of Contact
- Roland Lim,
- E-Mail Address
-
roland.lim@usace.army.mil
(roland.lim@usace.army.mil)
- Small Business Set-Aside
- N/A
- Description
- A market survey is being conducted to determine if there are a reasonable number of interested small business concerns to set this future project aside for them. If your firm is a Small Business, certified HUBZone, 8A, Woman-Owned Small Business or Service Disabled Veteran Owned Business and you are interested in this project please respond appropriately. The proposed project is for the construction of an Emergency Services Center (ESC) approximately 46,000 SF that consolidates the Police, Security, Fire, Crash-Rescue and Emergency Medical Team (EMT) Departments into a single, modern and centrally located facility located to service installation cantonment, housing, airfield and training areas on FHL. The ESC will include a primary building supporting the administrative, operations and classroom training requirements of the Departments; bay areas for the fire engines, ambulances; and a common dispatch center. Covered vehicle parking sheds will be provided for police vehicles and grass and forest firefighting equipment. A back-up power generator building with diesel generator and above ground fuel tanks will be required. Building will be of permanent construction with reinforced concrete foundations; concrete floor slabs; reinforced concrete or masonry walls; low-slope or sloped roof; HVAC - water source heat pump, and plumbing, mechanical, security and electrical systems. Supporting facilities include land clearing, paving, fencing, general site improvements and utility connections. Accessibility for the disabled is required and Anti-Terrorism/Force Protection (AT/FP) and physical security measures will be incorporated. Sustainability/Energy measures will be incorporated including maximum standoff distances from roads, parking areas and vehicle unloading areas. LEED Version 3.0 Silver Certification will be required. Contract duration is estimated at 540 days. The estimated cost range is between $10,000,000 and $25,000,000. NAICS code is 236220. All interested Small Businesses, certified HUBZONE, 8A, Woman-Owned Small Businesses or Service Disabled Veteran Owned Business contractors should respond to this survey by email 20 February 2017 by 1:00 PM Eastern Standard Time. Responses should include: 1. Identification and verification of the company's small business status. 2. Contractor's DUNs Number(s) and CAGE Code(s). 3. Documentation from the firm's bonding company showing current single and aggregate performance and payment bond limits. 4. Descriptions of Experience - Interested construction firms must provide no more than three (3) example projects with either greater than 90 percent completion or projects completed in the past five (5) years where the interested firm served as the prime contractor. Each project must include the name, title, project role, e-mail address, and telephone number of at least one reference. References may be used to verify project size, scope, dollar value, percentages and quality of performance. Example projects must be of similar scope and size. a. Projects similar in scope to this project include: Projects considered similar in scope to this project are new construction buildings to include but are not limited to: fire stations, police stations, and maintenance facilities. Renovation projects are not considered similar scope. b. Projects similar in size to this project include: Projects similar in size will include: experience with multi-story facilities, with two projects (two separate projects) similar or greater in size of approximately 35,000 SF. c. Based on the information above, for each project submitted, include: 1.) Current percentage of construction complete and the date when it was or will be completed. 2.) Scope of the project. 3.) Size of the project. 4.) The dollar value of the construction contract and whether it was design-bid build or design-build. 5.) The percentage of work that was self-performed as project and/or construction management services or physical construction type work. Must be at least 20% self-performed. 6.) Describe trades and work required to complete the project. Examples: types of mechanical systems, roofing systems, or specialty trades (Experience with water source heat pump HVAC system and with diesel emergency generator capability for entire facility). 7.) Provide 2 references. 5. Small Businesses are reminded under FAR 52.219-14, Limitations on Subcontracting; they must perform at least 15% of the cost of the contract, not including the cost of materials, with the firm's own employees for general construction-type procurement. Include the percentage of work that will be self performed on this project, and how it will be accomplished. NOTE: Total submittal package shall be no longer than 8 pages. Please only include a narrative of the requested information; additional information will not be reviewed. Email responses to Roland Lim at Roland.Lim@usace.army.mil. If you have questions please contact Roland Lim at Roland.Lim@usace.army.mil. This is NOT a Request for Proposal and does not constitute any commitment by the Government. Responses to this sources sought notice will be used by the Government to make appropriate acquisition decisions. All interested sources must respond to future solicitation announcements separately from responses to this market survey.
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/USA/COE/DACA27/W912QR-17-FHL-ESC/listing.html)
- Place of Performance
- Address: The ESC site is located northeast of the intersection of Hunter Liggett Road (Route Tampa) and 7th Division Road, Fort Hunter Liggett, California, 93928, United States
- Zip Code: 93928
- Zip Code: 93928
- Record
- SN04392241-W 20170208/170206235110-84a950a50ae384d594f29c0ade1b46a6 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |