DOCUMENT

54 -- Armory Vault - Attachment

Notice Date
2/9/2017
 
Notice Type
Attachment
 
NAICS
332311 — Prefabricated Metal Building and Component Manufacturing
 
Contracting Office
Department of Veterans Affairs;Network Contracting Office 22;4811 Airport Plaza Drive;Suite 600;Long Beach CA 90815
 
ZIP Code
90815
 
Solicitation Number
VA26217Q0434
 
Response Due
2/15/2017
 
Archive Date
4/16/2017
 
Point of Contact
Peter Kim
 
E-Mail Address
irport
 
Small Business Set-Aside
Veteran-Owned Small Business
 
Description
THIS REQUEST FOR INFORMATION (RFI) IS ISSUED SOLELY FOR INFORMATION AND PLANNING PURPOSES ONLY AND DOES NOT CONSTITUTE A SOLICITATION. THE SUBMISSION OF PRICING, CAPABILITIES FOR PLANNING PURPOSES, AND OTHER MARKET INFORMATION IS HIGHLY ENCOURAGED AND ALLOWED UNDER THIS RFI IN ACCORDANCE WITH (IAW) FAR 10.002(b). DISCLAIMER This RFI is issued solely for information and planning purposes only and does not constitute a solicitation. All information received in response to this RFI that is marked as proprietary will be handled accordingly. Responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to this RFI. SOURCES SOUGHT DESCRIPTION This is NOT a solicitation announcement. This is a sources sought/RFI only. The purpose of this sources sought/RFI is to gain knowledge of potential qualified sources and their size classification relative to NAICS 332311 (small business size standard of 750 Employees). Responses to this sources sought will be used by the Government to make appropriate acquisition decisions. After review of the responses to this sources sought, a solicitation announcement may be published. Responses to this sources sought synopsis are not considered adequate responses for a solicitation announcement. The Department of Veterans Affairs (VA), VISN 22 Network Contracting Office, is seeking sources that can provide a Modular Arms Vault that at a minimum meets the following salient characteristics for the VA Greater Los Angeles Healthcare System: 1. The entire armory assembly shall be weather proof for outdoor installation to withstand the local weather requirements. 2. Walls - Category II, Laminated ¼ inch exterior wall thickness, steel body with reinforced steel and rebar filled concrete fire proofing. Continuous welds in seams inside and outside body. Made in USA and inspected at the factory, walk in vault. 2 inch step door 60 minute fire proofing, with refrigeration gaskets. FEMA compliant, torch resistant. 3. Carpet - Provide industrial carpet on floor. VA Police will be choosing colors and material. 4. Custom locker shelving and gun racks - to accommodate 250 handguns and 50 rifles 5. Doors and Door Locks - The locking requirements (including access controlled egress doors) outlined in National Fire Protection Association (NFPA) Life Safety Code standard, latest edition, 101-7.2.1.5 and 7.2.1.6 must be followed. (a) Double fire proofing on door. 1 inch hard plate on outward swinging door. (b) Sargent & Green leaf lock with digital lock quick access. The lock shall be built within a weatherproof lock box enclosure (manipulation box). Sealed. The installation of high security exit devices meeting NFPA Life Safety Code standards is appropriate. (c) 1 inch solid steel hinges (d) Electronic/Magnetic locking systems. Where installed, electronic locking systems will include an automatic request to exit sensor and a push to exit manual lock release switch. Provide Internal Release. Refer to the NFPA Life Safety Code for details. (e) Two relockers in door. (f) Provide moisture barrier. 6. Paint - Provide hammered tone paint to withstand outdoor weather conditions and corrosion. Paint colors for outside and inside to be chosen by VA Police. Contractor to provide paint samples. 7. Steel Skid - Provide steel skid welded to the bottom of the armory, to elevate at least 3 inches of the concrete floor. Weather proof paint, seal ends of it, auto paint for outdoors. Contractor shall anchor to the concrete courtyard meeting the CA and VA seismic code requirements. 8. Motion Intrusion Detectors - An intrusion detection alarm system which detects entry into the room and which broadcasts a local alarm of sufficient volume to cause an illegal entrant to abandon a burglary attempt. Intrusion detector equipment which operates on the principle of narrow beam interception, door contacts, microwave, or photoelectric eyes are unacceptable as the primary means of detection. Intrusion detectors must have the following essential features. (a) An internal, automatic charging DC standby power supply and a primary AC power operations. (b) A remote, key operated activation/deactivation switch installed outside the room and adjacent to the room entrance door frame and/or a central alarm ON-OFF control in the Police office or other monitoring location. For personal safety reasons, alarm switches and panels will be located outside of the protected space. (c) An automatic reset capability following intrusion detection. (d) A local alarm level of 80 dB (min) to 90 dB (max) within the configuration of the protected area. (e) An integral capability for the attachment of wiring for remote alarm and intrusion indicator equipment (visual or audio). (f) A low nuisance alarm rate as defined in VA Master Specifications, Division 28 - Electronic Safety and Security 28 16 11 INTRUSION DETECTION SYSTEM. (g) In addition to the locally sounding alarm, remote visual and/or audio annunciators must be at a location within the facility which ensures 24 hour monitoring. These annunciators will have the capability of identifying individually protected zones. 9. Electronic Physical Access Control Systems (PACS) - For monitoring and controlling access to areas identified as requiring high or medium levels of assurance. (a) Access Safeguard. To prevent learning codes through keypad observations or use of stolen or found access cards. (b) Time Sensitive. The ability to program access by user, by shift and day. (c) Area Sensitive. The ability to program access by door and area for each individual user. (d) Fail-Safe. The ability to maintain access security if the system goes down (i.e. bypass key). (e) User Coverage. The number of individual access codes that the system will accommodate. (f) Personal Identifier Number (PIN) Codes. Access control systems protecting PACS high security areas, such as controlled substance storage, primary computer and communications rooms, research or clinical laboratories that store, use or develop biohazardous materials, require a PIN number as a secondary personal authentication to be used in addition to card readers. Scramble Pad type PIN readers are recommended when PIN systems are installed. See the table below for specific VA identified required locations. (g) Biometric Systems. Biometric security systems are those that use a personal measurement, such as fingerprints, hand geometry, facial geometry or iris scans, as authentication. Biometric devices can be used in lieu of PIN systems in PACS high protected spaces, but only as a secondary form of authentication. Biometric measurements may also be used in addition to a PIN in high security applications. The information identified above is intended to be descriptive, not restrictive and to indicate the quality of the supplies/services that will be satisfactory. It is the responsibility of the interested source to demonstrate to the government that the interested parties can provide the supplies/services that fulfill the required specifications. If you are interested, and are capable of providing the sought out supplies/services, please provide the requested information as well as the information indicated below. Response to this notice should include company name, address, point of contact, size of business pursuant to the following questions: 1. Please indicate the size status and representations of your business, such as but not limited to: Service Disabled Veteran Owned Small Business (SDVOSB), Veteran Owned Small Business (VOSB), Hubzone, Woman Owned Small Business (WOSB), Large Business, etc.)? 2. Is your company considered small under the NAICS code identified under this RFI? 3. Are you the manufacturer, distributor, or an equivalent solution to the items being referenced above? 4. If you re a small business and you are an authorized distributor/reseller for the items identified above or an equivalent solution, do you alter; assemble; modify; the items requested in any way? If you do, state how and what is altered; assembled; modified? 5. Does your company have an FSS contract with GSA or the NAC or are you a contract holder with NASA SEWP or any other federal contract? If so, please provide the contract number. 6. If you are an FSS GSA/NAC or NASA SEWP contract holder or other federal contract holder, are the items/solution you are providing information for available on your schedule/contract? 7. Please provide general pricing of your products/solution for market research purposes. 8. Please submit your capabilities in regards to the salient characteristics being provided to establish capabilities for planning purposes? Responses to this notice shall be submitted via email to peter.kim33@va.gov. Telephone responses shall not be accepted. Responses must be received no later than Thursday, February 16, 2016 at 10:00 a.m. PST. If a solicitation is issued it shall be announced at a later date, and all interested parties must respond to that solicitation announcement separately from the responses to this sources sought. Responses to this sources sought notice are not a request to be added to a prospective bidders list or to receive a copy of the solicitation.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/VA/LBVANBC/VAMD/VA26217Q0434/listing.html)
 
Document(s)
Attachment
 
File Name: VA262-17-Q-0434 VA262-17-Q-0434.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=3266696&FileName=VA262-17-Q-0434-000.docx)
Link: https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=3266696&FileName=VA262-17-Q-0434-000.docx

 
Note: If links are broken, refer to Point of Contact above or contact the FBO Help Desk at 877-472-3779.
 
Place of Performance
Address: VA Greater Los Angeles Healthcare System;11301 Wilshire Blvd;Los Angeles, CA
Zip Code: 90073
 
Record
SN04396977-W 20170211/170209234236-66b9e1c4b5369606c1f4b4301c09b236 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.