54 -- One (1) Modular Clean-room - Sources sought Document

Notice Date
2/14/2017
 
Notice Type
Sources Sought
 
NAICS
332311 — Prefabricated Metal Building and Component Manufacturing
 
Contracting Office
Department of the Army, Army Contracting Command, ACC - APG (W911QX) Adelphi, 2800 POWDER MILL RD, ADELPHI, Maryland, 20783-1197, United States
 
ZIP Code
20783-1197
 
Solicitation Number
W911QX-17-T-0089
 
Archive Date
3/8/2017
 
Point of Contact
Jamie N White, Phone: 3013941615
 
E-Mail Address
jamie.n.white2.civ@mail.mil
(jamie.n.white2.civ@mail.mil)
 
Small Business Set-Aside
N/A
 
Description
Salient Characteristics Sources Sought Document B. One (1) Modular Clean-room that meets the following requirements: Requirements for the following, One (1) 20' x 12' x 10' ISO 7 Clean room: 70oF +/- 2°F and Humidity 50% +5% Relative Humidity (RH) with similar modular design as follows: QTYDescription 1st Floor Walls 76 Classic Wall Panels, 11' Tall Exhaust Bender (EB-300) System 968 Fiber-Reinforced Plastic (FRP) Smooth Surface Upgrade 88 FRP Tex.Surface on (1) Side of 11' Wall Panel Structural Five (5) Corner Post, EB-300, 11' Tall Two (2) Wall Starter, EB-300, 11' tall Windows Three (3) Fixed Window w/ 1/4" TSG 4w' x 3'h Doors Four (4) 3' x 7' Steel Door Half w/ 1/4" TSG Window (2 6'x7' door entrances at front and back) Door Hardware Two (2)Door Closer Medium Duty Two (2)Gasket for a 36" Door Two (2)Lockset Americans with Disabilities Act (ADA) Lever Type in lieu of Standard Two (2)Sweep 36" Aluminum/Vinyl Ceiling/Dustcover 240 Deck-22 Galvalume (GA). Corrugated Steel Type B Deck 240 2'x4' Clean Room 870 Ceiling w/ Standard Grid 240 Plywood 3/4" Fire Resistant for Roof Deck (approximately 125lb/ft2) Clean Room Products Five (5) 16" x 16" Louver with 1" filter and Grill Five (5)HEPA Filter 2'x4' Motorized,18" deep Roomside Chan Support Steel 24 Angle Support Steel 3" x 3" x 1/4" Four (4)Beam to Beam/Column Connections Eight (8) Tube Insert for Wire Stud up to 12' Tall 48 W 8x10 Steel Support Beam $23.12 Electrical No Wire Two (2)Phone and CAT 5E Computer Jack w/ Junction Box Modular Electric One (1)Dedicated 220V Receptacle 20A (Modular) Five (5)Equipment Drop 110v (Modular) Four (4) Light Fluor. Cleanroom w/ Elec Ballast (Modular)(less One (1)125 Amp 12 Space CB Box w/ 6 Circuits (Modular) Two (2)Cable Set 11' Long 110v (Modular) One (1)Cable Set 11' Long 220V 20A (Modular) Five (5)Receptacle Duplex 110V W/ long cable to 16' (Modular) Two (2)Switch 1P w/ long cable to 16' (Modular) HVAC One (1)Split System 12,000 /12,000 HVAC 220V Accessories One (1)Caulk-Silicone Case (12 Tubes) Stair & Landing - Handrail 36 Hand Rail to OSHA 42" Tall 2 Rail w/ Kickplate One (1)Handrail 6' Wide Two 3' Swing Gates to OSHA One (1) Ladder Cage $100.04 15 Ladder Vertical w/ handrail Meet APG building requirements and include pricing for installation and connection to the B4600 Electrical system Fire Alarm system Sprinkler system References: show previous effort in building and completing a similar unit in government buildings (US Army TARDEC, APG tenants, US Gov)
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/notices/6f0ff3b19650d340d1e4a56cc66f9ef2)
 
Place of Performance
Address: 321 Colleran RD, Aberdeen Proving Ground, Maryland, 21005, United States
Zip Code: 21005
 
Record
SN04402354-W 20170216/170214234958-6f0ff3b19650d340d1e4a56cc66f9ef2 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.