Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY - FEDBIZOPPS ISSUE OF MARCH 15, 2017 FBO #5591
SOLICITATION NOTICE

W -- SHOWER UNITS- FT. PICKETT, VA

Notice Date
3/13/2017
 
Notice Type
Combined Synopsis/Solicitation
 
NAICS
532490 — Other Commercial and Industrial Machinery and Equipment Rental and Leasing
 
Contracting Office
Department of the Army, National Guard Bureau, USPFO for New Jersey, 3601 Technology Drive, Room 112, Ft Dix, New Jersey, 08640
 
ZIP Code
08640
 
Solicitation Number
W912KN-17-T-0011
 
Point of Contact
John M. Moreland, Phone: 609-562-0251
 
E-Mail Address
john.m.moreland.mil@mail.mil
(john.m.moreland.mil@mail.mil)
 
Small Business Set-Aside
Total Small Business
 
Description
This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in Subpart 12.6, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; proposals are being requested and a written solicitation will not be issued. This announcement is being issued as a Request for Quote (RFQ) unless otherwise noted herein. The NJ Army National Guard wishes to rent portable shower facilities in 3 locations to support XCTC 1701 at Fort Picket, VA. The supplier should provide service or maintenance and supervision of shower placement and/or replacement or removal. It will be necessary for the supplier to set up, install, maintain, take down, and transport all shower material and peripherals to and from the training sites upon completion. The supplier shall provide shower structures and shaving areas (sinks) as follows: PAX DATES OF USE 373 19 MAY - 9 JUNE 546 19 MAY - 9 JUNE 750 19 MAY - 9 JUNE These facilities must accommodate personnel composed of both genders. The supplier is also responsible to deliver and fill each shower facility with potable water. The supplier must also supervise and conduct the removal of gray water or waste water from the showers. The supplier is also required to stay to the end of the contract for disassembly, closing out contracts, and removal of equipment. 2. Shower facilities. The supplier shall be responsible for completion and assembly of the showers to meet the following specifications for their respective locations: -Shower capacity. Each shower facility at each location shall accommodate personnel numbers as indicated above on a continuous 24-hour basis. -Shower lighting. Each shower facility shall have lighting to allow personnel to see adequately while showering, washing, and shaving during limited natural light hours. There shall be external lighting on the shower facility to allow for safe movement into and from the shower facility. -Shaving stations. Each shower facility shall shaving stations assembled. Whether internal or external, shaving stations must allow personnel to have hot water, a basin, and mirror. -Power generation. Each shower facility shall have a power generation source (generator). Each shower facility shall have hot and cold running water and proper lighting. Power generation is essential. The supplier must provide maintenance to the power generation as well as the shower facility internal operation and controls. -Power distribution. Each specified shower facility shall have electrical outlets. It shall be the responsibility of the contractor to provide adequate electrical outlets. -Maintenance. The supplier shall be responsible for the 24-hour maintenance of the shower facility's plumbing, lighting, and power generation units. -Fuel. The supplier will provide standard, diesel fuel for the generators at each location. -Water. The supplier will ensure adequate water storage for fresh and grey water at each location and will deliver and refill fresh water and remove grey water for proper disposal. Water will supplied and discharged through Military Interdepartmental Purchase Request (MIPR) with Fort Pickett. -Maintenance. The supplier must provide 24-hour service and support to all power generation units. Only personnel authorized and certified by the contractor may perform maintenance on the equipment owned by the contractor. -Placement. A representative from the supported site will be on hand to assist the supplier with specific placement of the shower units. -Quality control. The supplier shall follow the quality standards of federal, state, and local government. Bid MUST be good for 30 calendar days after close of solicitation. This requirement is classified under NAICS code IS 532490. This solicitation requires registration with the System for Award Management (SAM) prior to award, pursuant to applicable regulations and guidelines. Registration information can be found at www.sam.gov. Any questions or comments should be directed to MAJ John Moreland, Contract Management Officer via e-mail at john.m.moreland.mil@mail.mil. All bids and quotes must be submitted to this email address; no other delivery methods are acceptable.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/USA/NGB/DAHA28/W912KN-17-T-0011/listing.html)
 
Place of Performance
Address: 2671 Armistead Ave., Fort Pickett, Virginia, 23824, United States
Zip Code: 23824
 
Record
SN04432555-W 20170315/170313234250-1dff106ad52c360650303208ecb73fea (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.