Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY - FEDBIZOPPS ISSUE OF MARCH 22, 2017 FBO #5598
SOLICITATION NOTICE

99 -- Request for information for the manufacturing of Diffuser Assemblies, Savannah River Nuclear Solutions, LLC

Notice Date
3/20/2017
 
Notice Type
Presolicitation
 
NAICS
339999 — All Other Miscellaneous Manufacturing
 
Contracting Office
Department of Energy, Savannah River Nuclear Solutions, LLC, Savannah River Nuclear Solutions, LLC, Savannah River Site, Bldg 730-2B, Aiken, South Carolina, 29808, United States
 
ZIP Code
29808
 
Solicitation Number
Diffusers32017
 
Archive Date
4/18/2017
 
Point of Contact
Lonnie Boleman, Phone: 803-952-9428
 
E-Mail Address
lonnie.boleman@srs.gov
(lonnie.boleman@srs.gov)
 
Small Business Set-Aside
N/A
 
Description
SRNS is in need of a hydrogen permeator (i.e. diffuser) to separate hydrogen isotopes from a gas stream consisting of various mixtures of helium, nitrogen, argon and hydrogen isotopes. The hydrogen permeator (i.e. diffuser) shall be designed to and capable of meeting the following: • Design Temperature: 600°C (1112°F) • Design Pressure: Full vacuum to 60 psig • The diffuser shall be designed, fabricated, inspected, and tested in a manner that meets the requirements of ASME B&PV Code Section VIII, Division 1 with the exception that the vessel is not to be stamped with the "U" symbol. Code compliant design calculations are required with the supplier's fabrication prints prior to fabrication release. • Normal Operating Temperature: 400 +/- 25°C • Normal Operating Pressure Range: Full vacuum to 2165 torr (41.86 psia) • Operational Feed Rate Capacity: 20 SLPM @ max operating pressure of 2300 torr (44.47 psia) • The pressure drop across the diffuser shall be less than 130 torr at 15.0 SLPM inlet flow rate. • Diffusers typically contain 1/8" palladium-silver tubes with a nominal composition of 75% palladium & 25% silver, with.003" -.004" nominal wall thickness. However, other sizes, compositions and thicknesses may be accepted with approval, e.g. 77% palladium, 23% silver. The tubes shall be configured in parallel and contain a minimum of 470 in2 membrane area of palladium/silver tubing. Feed gas shall be introduced to the inside of the tubes so that the direction of hydrogen diffusion is from the inside of the tubes to the outside. The feed gas shall enter the assembly at the same end as the bleed gas exits the assembly. The feed tube will also provide a means for the gas to be preheated prior to entering the palladium-silver tube. Bleed outlet gas shall exit from the tubes at the same end as the inlet feed. Pure hydrogen gas shall exit from a tube on the opposite end than the bleed and feed gas. • The internal diameter of the containment vessel shall be less than or equal to 6.0 inches (i.e. 6 inch Sch.80S pipe is acceptable). • The exterior of the diffuser vessel shall include a hydrogen permeation barrier. • The hydrogen permeator (i.e. diffuser) shall include the following: • Heater(s) capable of operating the diffuser at 400+/-25°C; heater(s) shall operate on 120 VAC, 60 Hz, single phase current. A Type "K" dual element thermocouple shall be integral to each heater to prevent the heater(s) temperature from exceeding Design Temperature. • Thermal insulation around the metallic vessel shall be sufficient to prevent external temperature from exceeding 60°C at maximum operating temperature of 425°C. • Based upon operating experience, the diffuser is expected to remove hydrogen isotopes from a nitrogen feed stream at 2 SLPM containing 1% hydrogen isotopes, producing a raffinate stream containing less than 0.03% hydrogen isotopes. The diffuser also shall be capable of removing hydrogen isotopes from a nitrogen feed stream at 1 SLPM containing 95% hydrogen isotopes, producing a raffinate stream containing less than 1% hydrogen isotopes. Note: The above design requirements are not all inclusive of the requirements within the official procurement specification, but are provided as a high level sample of the key design features.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/notices/77aa335cca62c329c46c7a8af95c17e0)
 
Place of Performance
Address: Savannah River Nuclear Solutions, LLC, Aiken, South Carolina, 29808, United States
Zip Code: 29808
 
Record
SN04440354-W 20170322/170320234036-77aa335cca62c329c46c7a8af95c17e0 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.