DOCUMENT
65 -- Ultrasound System - Attachment
- Notice Date
- 3/22/2017
- Notice Type
- Attachment
- NAICS
- 334510
— Electromedical and Electrotherapeutic Apparatus Manufacturing
- Contracting Office
- Department of Veterans Affairs;Network Contracting Office 2;James J. Peters VA Medical Center;130 West Kingsbridge Road;Bronx NY 10468-3904
- ZIP Code
- 10468-3904
- Solicitation Number
- VA24217Q0430
- Response Due
- 3/28/2017
- Archive Date
- 5/27/2017
- Point of Contact
- Paul Speedling
- Small Business Set-Aside
- Service-Disabled Veteran-Owned Small Business
- Description
- This is a SOURCES SOUGHT ANNOUNCEMENT ONLY. It is neither a solicitation announcement nor a request for proposals or quotes and does not obligate the Government to award a contract. Requests for a solicitation will not receive a response. Responses to this Sources Sought must be in writing. The purpose of this Sources Sought Announcement is for market research to make appropriate acquisition decisions and to gain knowledge of potential qualified businesses interested and capable of providing the requested commodities. This acquisition implements a 100% set aside for SDVOSBs. The NAICS Code is 334510; size standard is 1,250 employees. Responses to this notice shall include the following: (a) company name b) address (c) socio-economic status, (d) point of contact (e) phone, fax, and email (f) DUNS number (g) Cage Code (h) Tax ID Number (i) and must provide a capability statement that addresses the organizations qualifications and ability to perform as a contractor and provide the commodities described below. Portable Ultrasound - Podiatry Department See Statement of Work below. The Government is not obligated to nor will it pay for or reimburse any costs associated with responding to this sources sought synopsis request. This notice shall not be construed as a commitment by the Government to issue a solicitation or ultimately award a contract, nor does it restrict the Government to a particular acquisition approach. The Government will in no way be bound to this information if any solicitation is issued. Notice to Potential Offerors: All Offerors who provide goods or services to the United States Federal Government must be registered in the System for Award Management (SAM located on the web at www.sam.gov). It is desirable that any Offeror to have completed their business Online Representations and Certifications Application (ORCA). Additionally, all Service Disabled Veteran Owned Small Businesses or Veteran Owned Small Businesses who respond to a solicitation on this project must be registered with the Department of Veterans Affairs Center for Veterans Enterprise VetBiz Registry located at http://vip.vetbiz.gov. Requests for information and resultant responses shall be submitted directly to the contracting officer, Paul Speedling at Paul.Speedling@va.gov. NO TELEPHONE CALLS WILL BE ACCEPTED. All submissions should be received no later than 5:00 pm Eastern Standard Time on March 28, 2017. PORTABLE ULTRASOUND - PODIATRY DEPARTMENT BRAND NAME OR EQUAL SONOSITE EDGE II by FUJIFILM SONOSITE, INC. STATEMENT OF WORK: Scope of Work: Our scope would be to acquire one portable ultrasound unit with scanner heads suitable for compatible use by Orthopedics, podiatry and rheumatology. Requirements: Equipment to be delivered/assembled upon receipt to medical center with validation of performance Training of staff, minimum one person, to be performed on site Statement of warranty of equipment, minimum one year Statement of service included or for purchase: preventive maintenance; service and repair 15-6 MHZ Transducer Biopsy Compatible 13-6 MHz transducer Biopsy Compatible Triple Transducer Connect (TTC) w/ quick disconnect Product Specifications (Part Numbers and Description): L21822 SonoSite Edge II Ultrasound System QTY 1 EA SonoSite Edge II system includes the following software technologies: 2D grayscale with SonoMB Multi Beam Technology Auto Gain with SonoADAPT Tissue Optimization Technology M-Mode Application specific calculation packages Also includes battery, ultrasound gel, and user guide on a CD P21607 MSK Worksheets QTY 1 EA Worksheets specific to the Musculoskeletal clinician that includes Shoulder, Knee, Elbow, Hand/Wrist, Ankle/Foot, and Hip worksheets P21593 Color Application Package, SonoSite Edge II QTY 1 EA This package provides the following capabilities for the transducers that support these features: Tissue Harmonic Imaging (THI): Capability in which the system transmits at one frequency and receives at a higher harmonic frequency to reduce noise and clutter and improve resolution. SonoHD Imaging Technology: Significantly reduces speckle noise while enhancing tissue margins, thereby dramatically improving contrast and structural resolution. Velocity color flow imaging provides the clinician with the color sensitivity to perform color Doppler examinations with all transducers during a clinical procedure. PW Doppler is available on all transducers. CW Doppler is a quantitative assessment of blood flow with Duplex imaging for higher flow velocities. P21600 DICOM (Print, Store, Worklist, MPPS, Storage Commit) QTY 1 EA The DICOM package includes the capability to interface with PACS network with the complete offering of DICOM capabilities : print, store, worklist, storage commit, and modality perform procedure step. P07693 HFL50x / 15-6 MHz Transducer Biopsy Compatible QTY 1 EA HFL50x / 15-6 MHz multi-frequency, broadband, 50mm linear array transducer. This transducer is biopsy compatible. P20311 HFL38xi / 13-6 MHz Transducer Biopsy Compatible QTY 1 EA HFL38x / 15-6 MHz multi-frequency, broadband, 38mm linear array transducer. This transducer is biopsy compatible. L15800 EDGE Stand QTY 1 EA Ergonomic stand and mobile work platform for the EDGE, SonoSite Edge II system and transducers. Complete with power supply, mini-dock and accessory basket. OEM peripherals include: B/W or color printer. P20006 UPX898 Sony B and W Digital and Analog Printer QTY 1 EA Sony UP-X898MD compact, medical grade black and white hybrid printer with a USB 2.0 interface. P16535 Triple Transducer Connect (TTC) w/ quick disconnect QTY 1 EA Three-transducer module for mobile docking system that allows connection of up to three transducers simultaneously while the system is docked in the Stand. P20516 SonoSite EDGE II Ultrasound System User Guide English QTY 1 EA P21828 SonoSite EDGE II Ultrasound System Service Manual QTY 2 EA 5-YR Warranty 60 Months Standard Coverage QTY 1 EA
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/VA/BroVANAP/VAMD/VA24217Q0430/listing.html)
- Document(s)
- Attachment
- File Name: VA242-17-Q-0430 VA242-17-Q-0430.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=3356107&FileName=VA242-17-Q-0430-000.docx)
- Link: https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=3356107&FileName=VA242-17-Q-0430-000.docx
- Note: If links are broken, refer to Point of Contact above or contact the FBO Help Desk at 877-472-3779.
- File Name: VA242-17-Q-0430 VA242-17-Q-0430.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=3356107&FileName=VA242-17-Q-0430-000.docx)
- Place of Performance
- Address: Northport;VA Medical Center;79 Middleville Rd;Northport, NY
- Zip Code: 11768-2200
- Zip Code: 11768-2200
- Record
- SN04444457-W 20170324/170322235317-293f2a7663b947ac15dea0bad1eeb08a (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |