Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY - FEDBIZOPPS ISSUE OF APRIL 01, 2017 FBO #5608
SOURCES SOUGHT

Z -- SOURCES SOUGHT NOTICE FOR BUILDING 599 REPLACE FIRE ALARM SYSTEM, NSA Mid-South STATION MILLINGTON, TN

Notice Date
3/30/2017
 
Notice Type
Sources Sought
 
NAICS
238210 — Electrical Contractors and Other Wiring Installation Contractors
 
Contracting Office
N69450 NAVFAC Southeast, Southeast Bldg. 903 Building 903 P. O. Box 30 NAS Jacksonville Jacksonville, FL
 
ZIP Code
00000
 
Solicitation Number
N6945017R0807
 
Response Due
4/13/2017
 
Archive Date
12/31/2017
 
Point of Contact
Barbara Czinder at (904) 542-6834 or Barbara.czinder@navy.mil
 
E-Mail Address
source sought primary poc
(barbara.czinder@navy.mil)
 
Small Business Set-Aside
N/A
 
Description
SOURCES SOUGHT NOTICE FOR BUILDING 599 “ REPLACE FIRE ALARM SYSTEM, NSA Mid-South STATION MILLINGTON, TN Notice Type: Sources Sought Source Sought No: N69450-17-R-0807 Solicitation No: TBD Date: March 30, 2017 Response Date: April 13, 2017 Classification Code: Z “ Maintenance, Repair, and Alteration of Real Property NAICS Code: 238210 - Electrical Contractors and Other Wiring Installation Contractors This is NOT a solicitation announcement and there are no plans/specifications/drawings or bid package available for this project. This is a Sources Sought Synopsis announcement only. This synopsis is a market research tool being utilized for information to be used for preliminary planning purposes. The information received will be used within NAVFAC Southeast to facilitate the decision making process. It does not constitute a solicitation (Request for Proposal or Request for Quotations) or a promise to issue a solicitation in the future. NAVFAC Southeast is looking for responses from interested Prime Contractors. We are not seeking responses from firms interested in subcontracting opportunities. This is a survey of the market of potential U.S. Small Business Administration (SBA) certified 8(a), SBA Certified HUB Zone, Service Disabled Veteran-Owned Small Businesses (SDVOSB), Women Owned Small Business (WOSB), and Small Businesses (SB). Based upon this survey a decision will be made whether to issue the proposed solicitation for the types of firms indicated above or to issue as full and open competition (unrestricted). This notice does not constitute a Request for Proposal/Solicitation, Request for Quote, or Invitation for Bid and there are no plans or specifications for this notice. The intent of this notice is to identify potential offerors. It is not to be construed as a commitment of the Government for any purposes other than market research and is not restricted to a particular acquisition approach. No reimbursement will be made for any costs associated with providing information in response to this announcement or any follow-up information requests. Respondents will not be notified of the evaluation and any information submitted by respondents to this notice is strictly voluntary. If a solicitation is issued the solicitation number WILL NOT be the number same as the source sought notice number. It is the potential offerors responsible to check the Navy Electronic Commerce Online (NECO) website (https://www.neco.navy.mil) and the Federal Business Opportunities website. NAVFAC Southeast is seeking qualified businesses with current relevant experience to perform the following as described below: Project Description: Project includes modernization of fire protection systems in a 46,000 square foot three-story building consisting of primarily residential rooms and a multipurpose room at NSA Mid-South, Millington, TN. Work within the building includes: reconfiguration and modernization of existing fire sprinkler systems, demolition of existing fire alarm system and installation of complete fire alarm and mass notification system. The new fire alarm and mass notification systems include control panels, fire alarm radio transmitters, notification devices, initiating devices, conduit, wiring, and any other equipment needed for a complete system. NAICS Code: 238210 - Electrical Contractors and Other Wiring Installation Contractors with the annual size standard of $15 million. Project Magnitude is $1 Million to $5 Million. Submission Package: Interested sources are invited to respond to this sources sought announcement by submitting the following information: 1.Contractor Information: Provide your firm ™s contact information, to include DUNS and Cage Code numbers. 2.Indicate if a solicitation is issued will your firm/company be submitting a proposal: _____ Yes ______No. 3.Type of Business: U.S. Small Business Administration (SBA) certified 8(a), SBA Certified HUB Zone, Service Disabled Veteran-Owned Small Businesses (SDVOSB), Women Owned Small Business (WOSB), and Small Businesses (SB). For more information on the definitions or requirements for these small business programs, refer to http://www.sba.gov. 4.Bond Capacity: Provide your surety ™s name, your maximum bonding capacity per individual project. Offeror ™s must be able to bond at the project magnitude range of $1 Million to $5 Million. 5.Experience Submission Requirements: Submit a minimum of two (2) Design-Build projects, to that demonstrate experience in SELF-Performing fire protection system installation efforts of a similar size, scope and complexity to the project description above; and completed within the last seven (7) years. With an approximate Fire Protection System scope value of $400,000 or greater. Each project submitted must demonstrate scope in at least two of the following fire protection systems to be considered similar in scope and complexity: 1. Fire Suppression System (automatic sprinklers, gaseous or foam systems); 2. Fire Alarm Systems (fire detection system, fire notification systems, fire reporting systems, or mass notification systems); 3. Fire Water Supply Systems (fire mains, tanks or fire pumps). Work that was Sub-Contracted out will not be considered. Submissions shall contain the following items below (a “ g) for each project submitted for consideration. a.Include Contract Number, if applicable b.Indicate whether Prime contractor or Subcontractor c.Contract Value d.Value of Fire Protection System scope e.Completion Date f.Government/Agency point of contact and current telephone number. g.Project Description. Include a brief description, with sufficient detail, to determine whether this project is of a similar size and scope to the project description in this announcement; and, how the contract referenced relates to the project description herein. h.Indicate whether the project is Design Build. Capability Statements consisting of appropriate documentation, literature, brochures will be accepted providing it contains ALL the information required above (items 1-5). Complete submission package shall not exceed 15 pages. This package shall be sent by email, no larger than 6 MB, to the following email addresses: Barbara.Czinder@navy.mil. OR via mail to Naval Facilities Engineering Command, Southeast Attn: Barbara Czinder, IPT-Gulf Coast P.O. Box 30 Jacksonville, FL 32212-0030 Or Naval Facilities Engineering Command, Southeast Attn: Barbara Czinder, IPT-Gulf Coast Bldg. 903, Yorktown Jacksonville, FL 32212-0030 Submissions must be received at the email addresses cited or via mail no later than 3:00 PM Eastern Time on 13 April 2017. LATE SUBMISSIONS WILL NOT BE ACCEPTED. Questions or comments regarding this notice may be addressed to email addresses above or by phone to Barbara Czinder at (904) 542-6834.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/notices/52361f04ebad66dcc7ad3c38777cbd92)
 
Record
SN04454868-W 20170401/170331000145-52361f04ebad66dcc7ad3c38777cbd92 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.