SOLICITATION NOTICE
65 -- Regulated Med Waste Storage Container
- Notice Date
- 3/30/2017
- Notice Type
- Presolicitation
- NAICS
- 562112
— Hazardous Waste Collection
- Contracting Office
- Department of the Army, U.S. Army Medical Command, REGIONAL HEALTH CONTR OFC EUROPE, ATTN:MCAA E, CMR 402 Box 1376, Landstuhl Germany APO, 09180-3460, United States
- ZIP Code
- 09180-3460
- Solicitation Number
- W9114F-17-T-0041
- Archive Date
- 5/6/2017
- Point of Contact
- Nicholas J. Rowton, Phone: 01149637194644157, James K. Butler, Phone: 11-49-6371-9464-5404
- E-Mail Address
-
nicholas.j.rowton.civ@mail.mil, james.k.butler.civ@mail.mil
(nicholas.j.rowton.civ@mail.mil, james.k.butler.civ@mail.mil)
- Small Business Set-Aside
- N/A
- Description
- CLIN 0001 Regulated Med Waste Storage Container FFP Fire-Rated Storage Container (For Outside Storage). Requirements must Include: Frame construction made of sand blasted sections Roof and side walls must be made of fire resistant casing (EI 120) with fire protection for inside and outside. Color Outside paint container RAL 9002 (Grey white) Inside paint container RAL 9002 (Grey white) Inside/Outside paint door RAL 9002 (Grey white) Layer thickness color 80 μm Dimensions Outside width [meter] 2.505 depth [meter] 3.760 hight [meter] 2.400 Transport hight [meter] 2.500 Inside width [meter] 2.190 depth [meter] 3.445 hight [meter] 2.100 Treshold high 176 Galvanized sump made of steel with 5mm thickness Sump volume volume steel sump [Liter] 1.000 Door Door EI2 90-C Door model Double door, DIN right Door position short side, centrally Door wide [meter] 2-wing 1.915 Door high [meter] 2-wing 1.955 Loads and weights Snow-load sk [kN/m²] 2,5 Wind-load q (w,k) [kN/m²] 0,58 Max. load flat grids [kg/m²] 1.000 Council load flat grids [kg/200 x 200 mm] 140 Mesh flat grids [mm] --- Total weight container [kg] 2.500 Air Cooling System Air Conditioner Outside/Inside Room temperature min. +10 °C (heating) at an external temperature of - 15 °C max.+15 °C (cooling) at an external temperature of + 35 °C Connection voltage 400 V, 50 Hz Air circulation - Room heater Air cirulation heater, spray water protected, safety class IP 54 Assembled and wired until main connector Designed to support the heating function of the air conditioning Heat output 3 kW Electrical connection 400 V Built in Lighting Comfort control (switch cabinet) For the control of a container with a door latch, lighting and climate control equipment Climate control Comfort Control with LCD graphical display for monitoring and control of the cooling and/or heating function of the hazmat container with climate control system Driveway ramp for hand lift trucks Width ca. 1.000 meter Depth ca. 1.700 meter Wheel load 400 kg Angle of elevation 5 ° CLIN 0002 Delivery & Removal of Existing Container FFP Door-to-Door Delivery STUTTGART ARMY HEALTH CLINIC 2300 BLDG STUTTGART 70569 CLIN 0003 Electrical Installation FFP Electrical onsite Installation shall be provided by the contractor to include all required materials. Contractor must ensure all equipment is operational.
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/USA/MEDCOM/DADA19/W9114F-17-T-0041/listing.html)
- Place of Performance
- Address: STUTTGART ARMY HEALTH CLINIC, 2300 BLDG, STUTTGART GERMANY 70569, STUTTGART, Non-U.S., 70569, Germany
- Record
- SN04455158-W 20170401/170331000401-c8fed614b51a8405080dd2f48045668c (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |