Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY - FEDBIZOPPS ISSUE OF APRIL 07, 2017 FBO #5614
DOCUMENT

65 -- STL- Optical Coherence Tomography (OCT) Scanning System - Attachment

Notice Date
4/5/2017
 
Notice Type
Attachment
 
NAICS
334510 — Electromedical and Electrotherapeutic Apparatus Manufacturing
 
Contracting Office
Department of Veterans Affairs;Network Contracting Office (NCO) 15;3450 S 4th Street Trafficway;Leavenworth KS 66048
 
ZIP Code
66048
 
Solicitation Number
VA25517N0448
 
Response Due
4/10/2017
 
Archive Date
4/20/2017
 
Point of Contact
Donald E Hannah
 
E-Mail Address
6-1972<br
 
Small Business Set-Aside
Service-Disabled Veteran-Owned Small Business
 
Description
Sources Sought: VA255-17-N-0448 The VA St. Louis Health Care System is in need of an Zeiss Optical Coherence Tomography (OCT) scanning system or equal This is Sources Sought Notice is issued for information and planning purposes only. This is not a solicitation or a request for proposal. An award will not be made on offers received in response to this notice, and it shall not be implied the Government is committed to providing any solicitation or award following this notice. The Government will not pay for any information received in response to this request, nor will the Government compensate a respondent for any costs incurred in developing information provided. Responses shall be submitted by 10:00 am EST on Monday, April 10th, 2017. This Sources Sought Notice is for informational and planning purposes only and shall not be construed as a solicitation or as an obligation or commitment by the Government at this time. This notice is intended strictly for market research. The purpose of this Sources Sought notice is to determine interest and capability of potential vendors, including Small Business, Veteran-Owned Small Business (VOSB), and Service-Disabled Veteran-Own Small Business (SDVOSB) vendors relative to the North American Industry Classification System (NAICS) Code 334510. Department of Veterans Affairs, Network Contracting Office 15 (NCO15) is seeking responses to this request for information from interested, capable firms that can meet the requirements set forth below; The overall purpose is to provide Zeiss Optical Coherence Tomography (OCT) scanning system or equal to the Saint Louis, MO. Department of Veterans Affairs Medical Center located at 915 N. Grand Blvd, Saint Louis, MO. 63106. SALIENT CHARACTERISTICS (BRAND NAME OR EQUAL TO): 1 (EA) ITEM# 266002-1160-391 ZEISS OS CIRRUS HD-OCT (MODEL 5000) W/ANGIOPLEX OCT ANGIOGRAPHY VERSION 9.0. INCLUDES SMART HD SCANS, FASTTRAC, ADV RPE, GCA, PRINTER & TABLE ****INCLUDED WITH THE PURCHASE OF A CIRRUS 5000 IS: 266002-1157-764 - PREMIER ANTERIOR SEGMENT**** **TECHNICAL SPECIFICATIONS** CAPABILITY TO HAVE THE ABILITY TO CAPTURE AND PROVIDE OCT ANGIOGRAPHY: ANGIOGRAPHY PROVIDED BY A 1 SINGLE OCT SCAN THAT ALLOWS FOR VISUALIZATION OF BOTH MICRO VASCULAR AND STRUCTURAL INFORMATION IN AN NONINVASIVE DYE FREE SCAN BY THE OCT. ABILITY TO IMPORT AND INTEGRATE THE CIRRUS MODEL HD OCT 4000 RAW DATA. THE RAW DATA MUST BE INTERCHANGEABLE BETWEEN THE CIRRUS 4000 AND CIRRUS 5000 UNIT (OR NEW UNIT BEING PROCURED). THE UNIT MUST HAVE EXACT MACULAR SCAN PATTERN OF 512X128 FOR RETINA SCAN WITH EXACT SCANNING SPEED AT 27,000 A-SCANS A SECOND WITHIN A 6MMX6MM. MUST BE ABLE TO PROVIDE ON COMPANY LITERATURE. THE UNIT MUST HAVE EXACT SCAN PATTERN OF 200X200 IN A 6MMX6MM CUBE FOR GLAUCOMA SCAN WITH EXACT SCANNING SPEED AT 27,000 A-SCANS A SECOND. THE SCAN PATTERN MUST BE ABLE TO CAPTURE AND PROVIDE RNFL,ONH, NEURO RETINAL RIM TISSUE, AND 3-D CUBE CAPABILITIES ALL IN ONE SCAN SCANNING SPEEDS: SCAN AT EXACTLY 27,000 A-SCANS/SEC, AS WELL AS THE ABILITY TO SCAN AT 68,000 A-SCANS/SEC UNIT MUST BE ABLE TO PROVIDE A REPORT FOR GANGLION CELL. Analysis that is derived from a scan must be comprised of 6mmx6mm cube scan with a minimum by 200x200 line scan pattern with no more than 30 microns between each slice. Minimum Pupil Requirements must be 2.0mm or less. Unit must utilize an LSO Fundus Camera (Line Scanning Laser Ophthalmoscope). The unit must Automatically Track to Prior Scan: The unit must be able to do this without technician needing to align to prior scan: Anterior Segment scan that is at minimal 15.5 mm in length x 5.8 mm in depth. which is the full view of the Anterior Chamber. Must be able to provide on Company Literature. Global Pachymetry report that is comprised of minimum of 24 radial scans and must be at a minimum 9mm in length. The unit must be a 90 degree configuration, so that the tech (operator) must sit to the side (90 degrees) of the pa OCT Imaging: Methodology - Spectral domain OCT, Optical source - Superluminescent diode (SLD), 840 nm Scan speed - 27,000 A-scans per second or 68,000, A-scans per second**All existing scan patterns in version 6.5 software will run at 27,000 A-scans per second, which is the same scan speed as the CIRRUS 4000. **All patient data from the Cirrus 4000 instrument can be transferred into the Cirrus 5000 seamlessly and used immediately for Guided Progression Analysis or any A-scan depth - 2.0mm (in tissue), 1024 points Axial resolution - 5 um (in tissue) Transverse resolution - 15 um (in tissue) Cube scan pattern - 512 x 126 with over >67 million data ports and 47um spacing between lines Cube scan pattern - 200 x 200 with over >40 million data ports and 30um spacing between lines Fundus Imaging: Methodology - Line scanning ophthalmoscope (LSO) Live fundus image - during alignment and during OCT scan Optical source - Superluminescent diode (SLD), 750nm Field of view - 36 degrees Wx 30 degrees H Frame rate - >20 Hz Transverse resolution - 25 um (in tissue) Iris Imaging: Methodology - CCD Camera Resolution - 1280 x 1024 Live iris image - During alignment Electrical and Physical: Weight - 80 lbs. Dimensions of instrument - 26L x 18Wx 21H (in) Dimensions of table - 39L X 22W(in) Fixation: Internal fixation focus adjustment - -20D to +20D (diopters) Electrical rating (115V) - Single Phase, 100-120V~systems: 50/60Hz, 5A Electrical rating (230V) - Single Phase, 200-240V~systems: 50/60Hz, 2.5A Internal Computer: Operating system/processor - Windows 7, i& Intel Processor Memory: Hard drive/internal storage - >=750 GB, > 80,000 scans Display - Integrated 19" color flat panel display USB ports - 6 ports Responding companies shall include any relevant information (specifications, cut sheets, brochures, capability statement, etc.) confirming their ability to supply product with the salient characteristics outlined in this request. In addition to providing all documents necessary to validate the above requirements can be met (or exceeded), interested vendors shall include with their response: Complete Company Name and Address: DUNS Number: Applicable NAICS Code and Business Size: Company Point of Contact (PCO) Name: Email Address: Phone Number: Teaming Agreements or Joint Venture Partners (if Large Business): Delivery and installation lead-time: Place of Manufacture: State if items are available through an existing Government-wide Acquisition Contract (GWAC), GSA Multiple Award Schedule (MAS) contract, or VA-wide Acquisition Contract. Responses to this notice are not offers and cannot be accepted by the U.S. Government to form a binding contract or agreement. This notice shall not be construed as a commitment by the Government to issue a solicitation, or ultimately award a contract, nor does it restrict the Government to a particular acquisition approach. The Government will in no way be bound to this information if any solicitation is issued.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/VA/LeVAMC/VAMCKS/VA25517N0448/listing.html)
 
Document(s)
Attachment
 
File Name: VA255-17-N-0448 VA255-17-N-0448.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=3395297&FileName=VA255-17-N-0448-000.docx)
Link: https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=3395297&FileName=VA255-17-N-0448-000.docx

 
Note: If links are broken, refer to Point of Contact above or contact the FBO Help Desk at 877-472-3779.
 
Record
SN04460917-W 20170407/170405235002-62b838c666ece090e6da50a04372aad6 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.