SOURCES SOUGHT
Z -- Chiller Removal & Installation at the Roswell Federal Building - Sources Sought-Attachment A
- Notice Date
- 4/10/2017
- Notice Type
- Sources Sought
- NAICS
- 238220
— Plumbing, Heating, and Air-Conditioning Contractors
- Contracting Office
- General Services Administration, Public Buildings Service (PBS), R7 Acquisition Management Program Support Branch (47PH08), 819 Taylor St., Rm. 12B01, Fort Worth, Texas, 76102, United States
- ZIP Code
- 76102
- Solicitation Number
- GS-07-P-17-HT-C-Roswell
- Archive Date
- 5/3/2017
- Point of Contact
- Shawna M. Villarreal, Phone: 8178505541
- E-Mail Address
-
shawna.villarreal@gsa.gov
(shawna.villarreal@gsa.gov)
- Small Business Set-Aside
- N/A
- Description
- Sources Sought-Attachment A Project Description The General Services Administration, Public Building Service, Region 7, is issuing this sources sought synopsis as a means of conducting market research to identify parties having an interest in and the resources to remove two (2) 80 ton chillers and condenser/chilled water pumps. Upon completion of the project, the chillers shall be connected to the common building chilled and condenser water loops and Building Automation System (BAS). The Place of Performance is at the Federal Building, 500 N. Richardson Ave, Roswell, NM. All necessary connections, valves, pumps, piping and electrical modifications shall be included. The Contractor will have 45 days to complete the work after the equipment arrives on site. All work shall be completed within 240 calendar days of partial Notice of Proceed. The chiller requirements are as follows: New Chiller Requirements: -Minimum 80 tons of cooling -IPLV-.346 -Evaporator EWT/LWT (F) 55/45 -Evaporator GPM- 175 -Condenser EWT/LWT (F) 85/95 -Condenser GPM- 250 -Evaporator Pressure Drop (Not to exceed) 5 psi (4 pass heat exchanger) -Condenser Pressure Drop (Not to exceed) 8 psi (4 pass heat exchanger) -Minimum two compressors per chiller The applicable North American Industry Classification System (NAICS) code to be assigned to this procurement is 238220; the associated small business size standard is 15 million. The magnitude for this project is between $500,000 to $1,000,000. THERE IS NO SOLICITATION AT THIS TIME. This request for capability information does not constitute a request for proposals. Submission of any information in response to this market survey is purely voluntary. The government assumes no financial responsibility for any costs incurred associated to this request for capability information. If your organization has the potential capacity to perform these contract services, please provide the following information: (1) A complete and current record of your registration within the System for Award Management, located at https://www.sam.gov/. The record shall include your DUNS number, organization name, address, contact name, email address, web site address, telephone number, type of organization, and small business type(s). (2) A capability statement supporting claims of organizational and staff capability to perform the tasks listed in the "Project Description" paragraph above. (3) In order to demonstrate successful experience as a General Construction (GC) Contractor and/or as Plumbing, Heating, and Air Conditioning contractor, please provide at least three but no more than five similar chiller removal and installation projects (75 ton or larger water cooled chillers) substantially completed within the past five years from the issuance of this Sources Sought utilizing Attachment A. Detailed summaries that clearly demonstrate how the characteristics of the projects relate to the characteristics of this proposed project shall be provided. The total project construction cost at award of the similar projects must not be less than $325,000.00. GSA requests that potential sources only submit the minimum information necessary. The result of this market research will contribute to determining the method of procurement, including type of small business set-aside. NO LARGE businesses need to respond to this notice. Telephone inquiries will not be accepted or acknowledged, and no feedback or evaluations will be provided to companies regarding their submissions. However, GSA may contact sources to gather additional information as required. Submission Instructions: Interested parties, excluding large businesses, who consider themselves qualified to perform the above-listed services are invited to submit a response to this Sources Sought Notice by 2:00 PM (CDT), Tuesday, April 18. All responses under this Sources Sought Notice must be emailed to Shawna Villarreal, Contracting Officer, at the following address: shawna.villarreal@gsa.gov
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/GSA/PBS/7PMA/GS-07-P-17-HT-C-Roswell/listing.html)
- Place of Performance
- Address: Roswell Federal Building, 500 N. Richardson Ave., Roswell, New Mexico, 88201, United States
- Zip Code: 88201
- Zip Code: 88201
- Record
- SN04465813-W 20170412/170410235235-06c7b8bd893afd4dd29d7d10757f9ae6 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |