MODIFICATION
J -- F11 ELECTRICAL WORK
- Notice Date
- 4/12/2017
- Notice Type
- Modification/Amendment
- NAICS
- 238210
— Electrical Contractors and Other Wiring Installation Contractors
- Contracting Office
- USGS OAG DENVER ACQUISITION BRANCH PO BOX 25046 204 DENVER FEDERAL CENTER DENVER CO 80225-0046 US
- ZIP Code
- 00000
- Solicitation Number
- G17PS00296
- Response Due
- 4/17/2017
- Archive Date
- 5/2/2017
- Point of Contact
- Wilson, Mary
- Small Business Set-Aside
- Total Small Business
- Description
- AMENDMENT 00005 is issued to answer additional questions that were raised during the site visit and extend the due date to April 17 2017 in lieu of April 14, 2017. The are listed below: 1) In the SOW under "Relocation of electrical distribution panels" - DELETE Item #6 "Remove 3 phase wild leg feeder and install new 200amp 3 phase/4 wire feeder to new 3 phase panel." 2) What circuits are needed to bring to the new panels? Circuits that are required to operate the building ¿s heating and cooling system shall be connected in the new 3 phase panel. Single phase circuits P2/4 (for building security lighting) and P2/15 (Chemical Storage Building) shall be connected in the new single phase panel. Any required outage for the incoming line panel at breaker P5 shall be coordinated with the COR. Panel P5 operates building automation, communications networks, and alarm monitoring circuits. These circuits are critical to the operation of other buildings and equipment at the Center 3) Do we need to supply wet location conduit and fittings above the hard ceiling, or just for the portions below the hard ceiling in the areas where moisture will be present? Wet fittings only below the ceiling 4) Do we need to have wet location fixtures in the mechanical room? If so, do our panels need to be rated for wet location? No The U.S. Geological Survey has a requirement for commercial items prepared in accordance with the Simplified Acquisition Procedures authorized in FAR Part 13 and is requesting quotes for the procurement of electrical services to include electrical panel removal, new panel installation, installation of building lighting and branch wiring for lighting circuits in F11. The solicitation is issued as a request for quote (RFQ, subjected to the availability of funds. Submit written quotes and required documents on RFQ Number G17PS00296 to Beth Wilson at bwilson@usgs.gov The solicitation document and incorporated provisions and clauses are in effect through the latest Federal Acquisition Regulations and are attached. This solicitation is being issued as a Total Small Business Set-Aside. The associated NAICS code is 238210 Electrical Contractors and Other Wiring Installation Contractors. The Size Standard is $15.0 millions of dollars. All firms or individuals responding must be registered with the System of Award Management (SAM) www.sam.gov. This requirement is FOB Destination pricing to Columbia, MO 65201. All questions are to be submitted via email to Beth Wilson at bwilson@usgs.gov
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/DOI/USGS/USGS/G17PS00296/listing.html)
- Record
- SN04469747-W 20170414/170412234545-13abcbd81b6345f97dc5deb20d6b5b4f (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |