DOCUMENT
66 -- BIOLOGICAL SAFETY CABINET - Attachment
- Notice Date
- 4/17/2017
- Notice Type
- Attachment
- NAICS
- 334516
— Analytical Laboratory Instrument Manufacturing
- Contracting Office
- Department of Veterans Affairs;Network Contracting Office 20;5115 NE 82nd Ave, Suite 102;Vancouver WA 98662
- ZIP Code
- 98662
- Solicitation Number
- VA26017N0297
- Response Due
- 4/18/2017
- Archive Date
- 7/17/2017
- Point of Contact
- Gregory Watson
- E-Mail Address
-
y.watson2@va.gov<br
- Small Business Set-Aside
- N/A
- Description
- STATEMENT OF WORK/SALIENT CHARACTERISTICS Department of Veterans Affairs VA Puget Sound Health Care System 1. Overview: Seattle VAMC requires Prospective contractors to provide 1 NuAir NU-540-600 6 FT CLASS II, TYPE A2 BIOLOGICAL SAFETY CABINET and 1 NuAir NU-540-400 6 FT CLASS II, TYPE A2 BIOLOGICAL SAFETY CABINET. or Brand Name or Equal per FAR 52.211-6 Brand Name or Equal. 2. Objective: Our objective is to provide Seattle VAMC Microbiology with necessary equipment in order to provide the best care for our veterans. 3. Salient Characteristics Must meet minimum salient characteristics to be technically acceptable: 1. 6ft Class II, Type A2 Biological Safety Cabinet 2. Ultraviolet (UV) Light purchasable with Cabinet 3. Electrical: 115 VAC, 60 HZ 4. 16/18 GA Stainless Steel Interior/Exterior 5. Supplied with HEPA filters 6. Automatic Blower Cut Off when view screen is closed 7. At least 2 Duplex Outlets 8. At least 1 Service valve 9. At least 3 plugged couplings 10. Sliding View Window with 10 working access and alarm 11. Telescoping base stand with leg levelers 12. Able to convert to a non-recirculated air hood with variable flow exhaust transition with exhaust monitor Salient Specifications for 4ft BSL Hood Replacement for Microbiology 1. 4ft. Class II, Type A2 Biological Safety Cabinet 2. Ultraviolet (UV) Light purchasable with Cabinet 3. Electrical: 115 VAC, 60 HZ 4. 16/18 GA Stainless Steel Interior/Exterior 5. Supplied with HEPA filters 6. Automatic Blower Cut Off when view screen is closed 7. At least 2 Duplex Outlets 8. At least 1 Service valve 9. At least 3 plugged couplings 10. Sliding View Window with 10 working access and alarm 11. Telescoping base stand with leg levelers 12. Able to convert to a non-recirculated air hood with variable flow exhaust transition with exhaust monitor 13. Custom Exhaust Transition on left side for BSC.
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/VA/PoVAMC/VAMCCO80220/VA26017N0297/listing.html)
- Document(s)
- Attachment
- File Name: VA260-17-N-0297 VA260-17-N-0297_1.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=3423531&FileName=VA260-17-N-0297-004.docx)
- Link: https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=3423531&FileName=VA260-17-N-0297-004.docx
- Note: If links are broken, refer to Point of Contact above or contact the FBO Help Desk at 877-472-3779.
- File Name: VA260-17-N-0297 VA260-17-N-0297_1.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=3423531&FileName=VA260-17-N-0297-004.docx)
- Record
- SN04474372-W 20170419/170417234342-fe85cf0bdcc4fd771b8031501c5f471e (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |