Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY - FEDBIZOPPS ISSUE OF APRIL 22, 2017 FBO #5629
DOCUMENT

65 -- Activation: CB EQ02 - Ophthalmology - Attachment

Notice Date
4/20/2017
 
Notice Type
Attachment
 
NAICS
339112 — Surgical and Medical Instrument Manufacturing
 
Contracting Office
Department of Veterans Affairs;Program Contracting Activity Central;6150 Oak Tree Blvd, Suite 300;Independence OH 44131
 
ZIP Code
44131
 
Solicitation Number
VA70117Q0109
 
Response Due
4/17/2017
 
Archive Date
6/16/2017
 
Point of Contact
Jacquelyn Wise
 
Small Business Set-Aside
Service-Disabled Veteran-Owned Small Business
 
Description
2 INTRODUCTION The Veterans Health Administration (VHA), Program Contracting Activity Central (PCAC) anticipates soliciting quotations and subsequently awarding a Firm-Fixed-Price contract for various cleaning and recycling equipment products for the Eastern Colorado Health Care System. Acquisition of these items is part of the initial outfitting and activation of the new VA Medical Center being constructed in Aurora, CO. DESCRIPTION A contract is needed for the Eastern Colorado Health Care System for 13 Lensmeter, Automatic (JSN M5520), 11 Lamp, Slit, W/ Applanation Tonometer (JSN M5530), 11 Ophthalmoscope, Binocular, Indirect (JSN M5535), 11 Tester, Visual Acuity, Video/Microprocessor Based (JSN M5562), 11 Tonometer, Noncontact (Pen) (JSN M5575), 14 Unit, Exam, Eye, Motor Chair, w/power strip protection (JSN M5600), 11 Retinoscope, Streak (JSN M5605), 12 Frame Set, lens, Trial (JSN M5700), 1 Gauge, Distance, Pupillary (JSN M5705), 11 Mirror, Distance, Optometry (JSN M5710), 14 Stand, Instrument, Optometry (JSN M5730), 9 Refractor/Phoroptor (JSN U4142), 1 Pupilometer (JSN Z1132), 13 Chair, Glide (JSN Z1146), 11 Lens Set, Aspheric Clear, Optometry (JSN Z3083), 5 Prism Bars, Horizontal and Vertical, Optometry (JSN Z3084), 11 Occluder, Pinhole, Optometry (JSN Z3085), 11 Occluder, Black long Handle, Optometry (JSN Z3086), 11 Chart, Book Test, Fourteen Plates, Optometry (JSN Z3088), and 9 Well Handle (JSN Z1145). The contractor shall deliver all items. All items must meet all salient characteristics and the contractor shall furnish all personnel, supplies, and equipment required for delivery. SALIENT CHARACTERISTICS 1. Lensmeter, Automatic (JSN M5520) Quantity: 13 Marco Ophthalmic LM 101 (#4004) or Equal Specifications/Salient Characteristics: Standard lensmeter designed for measuring contact lenses and spectacle lenses. Includes a prism compensator, external power and axis readings, LED illumination, and an American-style cross-line target. The item shall be capable of operating on battery or AC power. The item shall meet the following technical specifications: Type: Ocular type; external reading Target: American Cross-line Vertex Power: Range: +25 to -25 diopters Step: 0.125 diopters up to ±3 diopters; 0.25 diopters beyond ±3 diopters Cylindrical Axis: Range: 0 to 180 degrees Step: 1 degree Prismatic Power: Range: 5 prism diopters in field of view; (20 prism diopters by prism compensator) Step: 1 prism diopter Eyepiece Focusing: +5 to -5 diopters Diameter of Lenses Accommodated: 24 to 90mm Lamp: AC 100V (LED illumination) Target Illumination: Switchable Dual color, Green/Orange LED (2V 25mA) Power source: DC 5V 1.2A (AC adapter 100~240V 50~60Hz 0.5A) 2 Each 1.5V D size battery (included) Tilting Angle: 0 to 90 degrees Color/Finish: Black Dimensions: At 0 degrees: 170mm (W) x 450mm (D) x 224mm (H) At 90 degrees: 170mm (W) x 342mm (D) x 470mm (H) Accessories/Configuration Options: Vinyl dust cover 7mm nosepiece Prism compensator 2. Lamp, Slit, W/ Applanation Tonometer (JSN M5530) Quantity: 11 Haag-Streit BQ900 LED or Equal Specifications/Salient Characteristics: Slit Lamp with applanation tonometer and LED light source for examination. The item shall meet the following technical requirements: Illumination Light-source: LED for examination (slit and background illumination) Slit width: 0 14 mm continuous Slit length: 1 14 mm continuous and fixed apertures Illumination field diameter: ΓΈ 8 / 5 / 3 / 2 / 1 / 0.2 mm Slit image rotatability: ± 90 ° Swiveling of the slit illumination to the microscope axis: Horizontal ± 90 °, vertical 0 20 ° Filters: Blue, red-free (green), grey (10 %), and optional yellow Microscope Ocular magnification: 12.5x Stereo angle: 13 ° (convergent optics) Range of adjusting eye-pieces: +7 to -7 diopters Pupil distance: 52 78 mm Magnification changer: 6.3x / 10x / 16x / 25x / 40x Object field ΓΈ in mm: 32.0 / 20.0 / 12.7 / 8.0 / 5.1 Instrument base Operation: Single handed 3-dimensional operation of the control lever Spatial adjustment of the instrument base: 100 mm (length), 100 mm (side), 30 mm (height) Color/Finish: Black Power: 100V; 50-60 Hz Approximate Dimensions: 312mm W x 676mm H x 305mm L Accessories/Configuration Options: Applanation Tonometer (AT 900 or Equal) 3. Ophthalmoscope, Binocular, Indirect (JSN M5535) Quantity: 11 Keeler Vantage Plus LED (1205P5010) or Equal Specifications/Salient Characteristics: Indirect ophthalmoscope Dimensions: Wireless Headband Device Accessories/Configuration Options: Camera: Interface: USB 2 Supply: Taken from USB 2 interface Resolution: To test pattern 6 of group 2 on the 1951 USAF TEST PATTERN (conforms to MIL-STD 150A standard), when used in combination with a 20D lens Lead: To connect camera to PC, Keeler recommends a maximum of 5m long USB 2.0A to mini 5 pin (sometimes packaged as USB 2.0A to mini B lead) Convergence: Range: The camera image can be adjusted ±7 degrees Working distance: Range: Nominal working distance of 440mm. The resolution value given above will be maintained at 350mm to 650mm distance from instrument to the eye under examination with a 20D lens Operating System: Use with: Windows 7 and Windows XP Vantage Plus: Controls: All controls and features of the Vantage Plus have been maintained Adjustment: Vertical adjustment: The vertical adjustment is achieved by rotating the adjustment screw on the mirror holder. The image should be adjusted such that the light patch is in the center. Horizontal adjustment: Factory set Depth of Field: ±35mm @ 440mm Must be Wireless 4. Tester, Visual Acuity, Video/Microprocessor Based (JSN M5562) Quantity: 11 Basis of Design: Reichert 13760 - Clear Chart 2 with Wall Mount Specifications/Salient Characteristics Dimensions: 19.88 W x 16.91 H x 3.25 D (19 LCD Display) Accessories/Configuration Options: Power Requirements: 100-240 volts AC, 50/60 Hz, 70-95 VA Refraction Range: 6 31 LED backlight Shall include an Infrared remote control Shall be capable of importing additional videos and image files to customize the system to fit needs via USB drive. Configure for direct or mirrored viewing Large range of optotypes: 17 letter set, 8 letter set, Sloan, HOTV, Landolt C, Landolt C and O, Tumbling E Shall have random sequencing of optotypes Shall include special Test Charts for astigmatism testing, suppression and fixation The contrast sensitivity testing shall come with sine-wave grating or contrast optotypes Shall comply with ETDRS protocol Shall have adjustable red/green for compatibility with any refraction system Shall include patient education slides Shall include wall mounting Shall integrate with the Reichert Auto Phoroptor RS 5. Tonometer, Noncontact (Pen) (JSN M5575) Quantity: 11 Basis of Design: Reichert Avia Tono-pen (TO0RE230650) Specifications/Salient Characteristics Dimensions: 6 1/4 L x 1 3/4 W Accessories/Configuration Options: Power requirements: Tono-Pen Avia Powercel Battery Pack (included) TONO-PEN AVIA Tonometer Starter Pack (Contains TONO-PEN AVIA, Carry Case, Instructional Manual and DVD, 1 box of 150 individually packaged OCU-FILM+ Tip Covers, 1 TONO-PEN AVIA POWERCEL Battery Pack) Shall be a hand-held instrument Shall function in any position for accurate IOP measurements. Shall include two large LCD screens for left or right handed individuals Shall have over molded grip zones for all hand sizes Shall be Portable Shall include a micro strain gauge 1.0mm diameter transducer tip 6. Unit, Exam, Eye, Motor Chair, w/power strip protection (JSN M5600) Quantity: 14 Basis of Design: Reliance 7000 Specifications/Salient Characteristics Dimensions: 24 1/4 W x 36 D x 20-29 H Accessories/Configuration Options: Power Requirements: 115 volts (standard) Shall possess a powered base Shall have an articulating top Shall contain power strip protection Shall have armrests Shall contain footstep-8 x 13 7. Retinoscope, Streak (JSN M5605) Quantity: 11 Basis of Design: Welch Allyn Elite18245 Specifications/Salient Characteristics Accessories/Configuration Options: Shall contain crossed linear polarized filter Shall have an external focusing sleeve Shall have the elite optical system Shall possess the ability for interchangeable bulbs streak filament bulb to spot filament bulb To be used with the rechargeable well handles (Z1145 in section 2.5.20) 8. Frame Set, lens, Trial (JSN M5700) Quantity: 12 Basis of Design: Topcon TLS 8AF Full diameter Plus and Minus w/ trial frame Specifications/Salient Characteristics Accessories/Configuration Options: Shall be a combination of spheres, cylinder, and accessory lenses Bi-convex and bi-concave lenses mounted in metal rims Shall have lens power on both sides of the handles Shall include velvet lined carrying case Lenses shall be compatible with instruments that require patients correction Shall include the lenses below: 9. Gauge, Distance, Pupillary (JSN M5705) Quantity: 1 Basis of Design: Topcon PD-5 Specifications/Salient Characteristics Dimensions: 155mm(W) x 255mm(D) x 55mm(H) Accessories/Configuration Options: Shall have corneal reflection coincidence system Shall have LCD display Shall poses 0.5mm measurements increments PD measurement range: 46-82mm in 0.5 increments 23-41mm for single-eye measurement Shall be able to measure fixation PD distance from 30cm to infinity Shall have a single eye shutter The Diopter shall be adjustable Power: 4 AA batteries 10. Mirror, Distance, Optometry (JSN M5710) Quantity: 11 Basis of Design: Omni Systems 0450 Mirror Set Specifications/Salient Characteristics Dimensions 13 x 13 Framed Accessories/Configuration Options: Shall be wall mountable Shall come in a pair or 2 11. Stand, Instrument, Optometry (JSN M5730) Quantity: 14 Basis of Design: Reliance 7800IC Specifications/Salient Characteristics Dimensions 36 H to top of console 71 H to top of pole Base: 21 x 21 Power: 115 volts, 60Hz,3 amperes Accessories/Configuration Options: Shall include 3 rechargeable instrument wells Shall be compatible with the examination chair (M5600) Shall include a counterbalanced slit lamp arm The console shall feature raise, lower, and auto down switches for the examination chair Shall have an overhead lamp on an adjustable arm 12. Refractor/Phoroptor (JSN U4142) Quantity: 9 Basis of Design: Reichert 11635B Specifications/Salient Characteristics Accessories/Configuration Options: Color: Black ±.25 Flip cross cylinder + 1.50 Retinoscopy Lenses 3 pair nylon face shields Rotochart Reading rod with card holder Sphere: -19.00D to +16.75D, 0.25D Steps, +0.12D Sphere in auxiliary dial included Cylinder Power: 0.00D to 6.00D, 0.25D Steps Cylinder Axis: 360 degrees (Double 0 to 180 degrees scale), 5 degrees graduations Cross Cylinder: ± 0.25 Prism: 0 to 20 Prism Diopter, 1 Prism Diopter graduations P.D.: 48 mm to 75 mm, 1 mm graduations Vertex Distance: 13.75 mm (normal)Graduations extend range by 6 mm Reading Distance: 5 to 28 inches, Centimeter and diopter scales included Auxiliary Dial: 10 lenses plus 2 open apertures 13. Pupilometer (JSN Z1132) Quantity: 1 Basis of Design: Reichert PDM Digital PD Dimensions 6 W x 9 L x 2 H Specifications/Salient Characteristics Accessories/Configuration Options: Shall have the cornea reflection light coincidence method Shall have a LCD display Focus range shall be 30cm to infinity Shall have a range of measurement consisting of: 46 to 82mm for total PD 23 to 41mm for each eye Graduations of 0.5mm Power: 4 AA batteries 14. Chair, Glide (JSN Z1146) Quantity: 13 Basis of Design: Reliance 940 Specifications/Salient Characteristics Dimensions Base plate: 28 L x 20 W Track: 3/4 W x 3/16 H x 52 long Accessories/Configuration Options: Shall be compatible with the examination chair (M5600) Helps the examination chair meet ADA requirements by allowing the chair to be pushed back so that a wheelchair can replace it. Shall have a locking pedal that secures the chair anywhere on the 27 path Shall have a tapered track for allowing the doctor to get closer to the patient without the glide being in the way 15. Lens Set, Aspheric Clear, Optometry (JSN Z3083) Quantity: 11 Basis of Design: Volk 20D, 78D, 90D, VG3, VG4, VSFNC Specifications/Salient Characteristics Accessories/Configuration Options: 20D Standard general diagnostic lens Balance of magnification and field view for general diagnosis Corrected for field curvature, astigmatism, aberrations, and coma Field of view: 46 degrees / 60 degrees Image magnification: 3.13x Laser spot magnification factor:.32x Working distance: 50mm 78D General diagnosis and laser treatment For use within range of motion of all slit lamps Field of view: 81 degrees / 97 degrees Image magnification:.93x Laser spot: 1.08x Working distance: 8mm 90D General diagnosis and small pupil examinations Ideal for fundoscopy Field of view: 74 degrees / 89 degrees Image magnification:.76x Laser spot: 1.32x Working distance: 7mm VG3 Viewing and treatment of the anterior chamber, central and peripheral fundus All glass design for clarity Mirrors eliminate gaps in the visualized fundus Ideal for gonioscopy Mirror angles: 60 / 66 / 76 degrees Image magnification: 1.06x Laser spot size:.94x Contact diameter: 15mm VG4 Standard gonio lens for static and dynamic gonioscopy All glass design for clarity Mirror angle: 4 x 64 degrees Image magnification: 1.0x Laser spot size: 1.0x Contact diameter: 8.4mm VSFNC Wide field, pan retinal examination Wide field of view Field of view: 95 degrees / 116 degrees Image magnification:.76x Laser spot: 1.3x Working distance: 7mm 16. Prism Bars, Horizontal and Vertical, Optometry (JSN Z3084) Quantity: 5 Basis of Design: Specifications/Salient Characteristics Accessories/Configuration Options: Vertical Prism Bar Diopter sizes: 1, 2, 3, 4, 5 6, 8, 10, 12, 14, 16, 18, 20, 25 and 30 Shall have the prism power markings on the front of the bar Horizontal Prism Bar Sizes: 1, 2, 4, 6, 8, 10, 12, 14, 16, 18, 20, 25, 30, 35, 40 and 45 Shall have the prism power markings on the front of the bar 17. Occluder, Pinhole, Optometry (JSN Z3085) Quantity: 11 Basis of Design: Lorgnette Pinhole Occluder Specifications/Salient Characteristics Accessories/Configuration Options: Shall have 17 holes (1.5mm) attached pinhole viewer Also known as a mask occluder Allows for either eye to be covered 18. Occluder, Black long Handle, Optometry (JSN Z3086) Quantity: 11 Basis of Design: Maddox Rod & Occluder Specifications/Salient Characteristics Accessories/Configuration Options: Occluder The occluder end is used for covering one eye during a test. Occluder is cupped at 70mm radius Maddox Rod Is used in conjunction with prisms for both near and distant vision 19. Chart, Book Test, Fourteen Plates, Optometry (JSN Z3088) Quantity: 11 Basis of Design: Ishihara 14 Plate Book Test & Stereo Fly Test Specifications/Salient Characteristics Accessories/Configuration Options: Plate Book Test: This test is an accurate method of discovering congenital color blindness and red-green blindness in complete and incomplete forms, full test consists of 38 plates, the 38 plate test is the most comprehensive There are a variety of colored dots that make up numbers in the center of the picture and are surrounded by different variety of colored dots. Stereo Fly Test This test is the standard for stereo depth-perception testing It shall evaluate gross stereopsis (2500 to 1200 seconds of arc) It shall also evaluate fine depth perception Shall include graded circle test (800 to 40 seconds of arc) Shall include a pair of standard 3-D viewing glasses 20. Well Handle (JSN Z1145) Quantity: 9 Basis of Design: Welch Allyn, Inc., WA-71670 Specifications/Salient Characteristics Dimensions 7 W x 2 D x 2 H Accessories/Configuration Options: 3.5V Rechargeable power handle Rechargeable NiCad Battery No-slip grip Chrome-plated brass construction Operation and Maintenance Manuals Training- vendor will provide one day (8 hours) of on-site training for end users and biomed personnel. Binders - Quantity (2) each for items identified above. Digital Copies - Quantity (1) each for items identified above. Deliver compilation of all manufacturer recommended maintenance schedule and operation materials packaged in binder(s) to On Site Point of Contact upon completion of delivery. DELIVERY AND INSTALLATION The Contractor shall coordinate delivery, staging areas, installation, site safety requirements, and parking with the On-site Point of Contact (POC). The On-Site Point of Contact will be designated after contract award. The Contractor shall participate in a pre-delivery meeting to determine delivery and installation dates. The Contractor shall verify delivery date three business days prior to scheduled delivery. Delivery Timeframe will be no earlier than 17 April 2017, no later than 19 May 2017. Acquisition of the above items is part of the initial outfitting and activation of the new VA medical center being constructed in Aurora, CO. Since construction is still occurring, delivery dates are approximate and will be coordinated with the successful contractor after award. The Contractor shall contact the On Site Point of Contact to schedule a pre-delivery meeting to be conducted approximately 60 days prior to the initial award delivery date for verification of delivery dates. r shall contact the On-Site Point of Contact to schedule a pre-delivery meeting to be conducted approximately 30 days prior to the initial award delivery date for verification of delivery and installation dates. The Contractor may be required to adjust the delivery date from the date specified in the contract award document. A government-requested delivery delay up to 90 days after the delivery date specified in the contract award shall be at no additional cost to the government. Contractor shall deliver items in manufacturer's original sealed containers with manufacturer s name marked thereon. Deliveries shall be marked with the PO and contract number. Items on delivery vehicles not equipped with a Lift Gate will not be accepted. The delivery will have to be rescheduled and any delivery charges will be the responsibility of the Contractor. SITE CONDITIONS Delivery may occur while the construction contractor is still working on the facility. Delivery and installation personnel must comply with all site safety requirements, to include the wearing of PPE. Minimum requirements are hard hat, over the ankle boots, reflective safety vest, eye protection and gloves. The Contractor shall confirm site safety requirements with the On-Site Point of Contact when coordinating delivery and installation. There shall be no smoking, eating, or drinking inside the construction site at any time. If the requirements iare not adhered to the delivery will be rejected and be rescheduled at Contractors expense. INSPECTION AND ACCEPTANCE The Contractor shall deliver and install all equipment to manufacturer s specifications and in accordance with Federal and local safety standards. Installation/Configuration shall commence upon day of delivery. All work shall be completed between 8:00 a.m. and 4:30 p.m. MST. Monday through Friday, excluding all Federal holidays (https://www.opm.gov/policy-data-oversight/pay-leave/pay-administration/fact-sheets/holidays-work-schedules-and-pay). The Contractor shall remove all related shipping debris and cleanup any materials and tools associated with delivery and installation of the specified items. Contractor shall remove all packaging from the ECHCS premises. The Contractor shall be responsible for any damage to the building that occurs due to Contractor error or neglect. The Contractor shall conduct a joint inspection with the On Site Point of Contact upon completion of delivery. In the event deficiencies are identified, the Contractor shall provide date when the identified deficiencies will be addressed if not addressed on the date of delivery. The Contractor shall conduct a joint inspection with the On Site Point of Contact after addressing all deficiencies. All deficiencies identified during joint inspections shall be fixed by the Contractor prior to government acceptance of the item. Disputes shall be resolved by the Contracting Officer. PROTECTION OF PROPERTY Contractor shall protect all items from damage during delivery and installation. The Contractor shall take precaution against damage to the building(s), grounds, and furnishings. Contractor shall be responsible for providing adequate floor and wall protection to minimize damage to the facility during delivery/installation of the items. It is recommended that all material handling equipment have rubber wheels to minimize potential damage to floors. The Contractor shall perform an inspection of the building(s) and grounds with the On-Site Point of Contact prior to commencing work. The Contractor shall be responsible for repairing or replacing any items that require simple repair, components, building(s), or grounds damaged due to negligence and/or actions taken by the Contractor or its employees. The source of all repairs beyond simple surface cleaning is the facility construction contractor (or appropriate subcontractor), so that building warranty is maintained. Concurrence from the VA Facilities Management POC and On-Site Point of Contact is required before the Contractor may perform any significant repair work. In all cases, repairs shall utilize materials of the same quality, size, texture, grade, and color to match adjacent existing work.The Contractor shall be responsible for securing the items and its own work tools and equipment during delivery/installation. SECURITY REQUIREMENTS Security background checks are not required. WARRANTY The contractor shall provide all manufacturer(s) warranties on all parts and labor at time of delivery. The warranties shall include all travel and shipping costs associated with any warranty repair. ADMINISTRATIVE The solicitation will be issued as a Request for Quote (RFQ) conducted in accordance with Federal Acquisition Regulation (FAR) Parts 12 and 13. The solicitation will be advertised as a total Service-Disabled Veteran-Owned Small Business set-aside. The applicable NAICS code is 339112 with a size standard of 500 Employees. The solicitation will be issued on or about April 25, 2017 for approximately seven (7) calendar days. Offerors will be required to submit their quotes electronically via email. This notice is not a request for competitive offers. Questions of a technical nature will not be answered as part of this notice; however, all general questions may be submitted in writing to the issuing office via email at jacquelyn.wise@va.gov. Telephone calls will not be accepted. The VA reserves the right to use only Federal Business Opportunities (FBO), via the internet, to provide notification of any amendments to this notice and the subsequent issuance of the solicitation. It is the contractor s responsibility to view FBO daily for any amendments to this notice and the subsequent issuance of the solicitation.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/VA/ISC/OISC/VA70117Q0109/listing.html)
 
Document(s)
Attachment
 
File Name: VA701-17-Q-0109 VA701-17-Q-0109.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=3431352&FileName=VA701-17-Q-0109-000.docx)
Link: https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=3431352&FileName=VA701-17-Q-0109-000.docx

 
Note: If links are broken, refer to Point of Contact above or contact the FBO Help Desk at 877-472-3779.
 
Place of Performance
Address: DELIVERY TO:;Eastern Colorado Health Care System;1700 N. Wheeling St.;Aurora, CO
Zip Code: 80045
 
Record
SN04480135-W 20170422/170421000008-6cadcea5607214c800617f5fd2e424ec (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  © 1994-2020, Loren Data Corp.