Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY - FEDBIZOPPS ISSUE OF APRIL 26, 2017 FBO #5633
DOCUMENT

66 -- Sources Sought Notice - Attachment

Notice Date
4/24/2017
 
Notice Type
Attachment
 
NAICS
333314 — Optical Instrument and Lens Manufacturing
 
Contracting Office
Department of Veterans Affairs;Network Contracting Office 2;James J. Peters VA Medical Center;130 West Kingsbridge Road;Bronx NY 10468-3904
 
ZIP Code
10468-3904
 
Solicitation Number
VA24217Q0564
 
Response Due
4/27/2017
 
Archive Date
5/7/2017
 
Point of Contact
Tina.Cavalieri@va.gov
 
E-Mail Address
tina.cavalieri@va.gov
(tina.cavalieri@va.gov)
 
Small Business Set-Aside
Service-Disabled Veteran-Owned Small Business
 
Description
THIS IS NOT A REQUEST FOR QUOTES OR PROPOSALS. The Government is seeking information for market research purposes only. Your responses to the information requested will assist the Government in determining the appropriate acquisition method. A solicitation is not currently available. The Government may or may not issue solicitation documents. The Department of Veterans Affairs, Veterans Integrated Service Network (VISN 2), is conducting market research for an SDVOSB set aside, capable of providing the following products to the James J. Peters Medical Center at 130 West Kingsbridge Road, Bronx NY 10468. The contractor shall provide Zeiss OS/CIRRUS HD-OCT/VISUPAC and components and all resources necessary to accomplish the deliverables described below for the Eye Clinic located at the James J. Peters VA Medical Center. Item # Description/Part Number* Qty Price Extended Amount 1 Zeiss os/Cirrus HD-OCT 1 2 ZEISS OS | ANTERIOR SEGMENT PREMIER MODULE (IMAGING &MEASUREMENTS) INCLUDES EXTERNAL LENS KIT 1 3 Trade In : Cirrus 4000-6295 1 4 ZEISS OS | VISUPAC 500 W ZK5 & PIKE 145 1 5 ZEISS OS | AUTOFLUORESCENCE FILTER SET, 1 6 ZEISS OS | IT1060 TABLE WITH FF450PLUS POWER SUPPLY 1 7 One Year Warranty 1 8 Installation 1 9 Training 1 10 Operator Manuals 2 11 Service Manuals 2 ANY OR EQUAL BRAND MUST HAVE EQUAL SPECIFICATIONS TO THE PART NUMBER(S) REQUESTED. IF RESPONDING WITH AN OR EQUAL BRAND YOU MUST PROVIDE THE SPECIFICATION SHEET OF YOUR SUGGESTED PART NUMBERS OR YOU WILL BE DEEMED NON RESPONSIVE. It is the vendors responsibility to fully research the items listed for compatibility. Applicable NAICS Code is 333314, with a Small Business size standard of 500 Employees. Offerors desiring consideration shall email a capabilities statement and the following information directly to the Contracting Officer referencing the following in the subject field, VA242-17-Q-0564- Zeiss OS/CIRRUS HD-OCT/VISUPAC ". Offerors, at the time of response, shall be verified in VIP. Unverified SDVOSB s will be considered non-responsive to the requirements of this sources sought and any resulting solicitation. Offers from unverified SDVOSBs/VOSB s are considered deficient and will not be evaluated. Company Name: Socio-Economic Category (SDVOSB): Street Address, City, State and Zip Code: DUNS Number: Point of Contact Name: Point of Contact Phone Number: Point of Contact E-mail Address: IMPORTANT NOTE: Responses to this Sources Sought notice must be submitted via e-mail to the Contracting Officer's E-mail: tina.cavalieri@va.gov and received no later than Thursday, April 27, 2017 @ 11AM. This is a market survey for informational and planning purposes only. THIS IS NOT A SOLICITATION AND DOES NOT OBLIGATE THE GOVERNMENT TO ISSUE A SOLICITATION. Please be advised that the Government will not pay for any information submitted under this announcement. STATEMENT OF NEED James J. Peters VA Medical Center 130 West Kingsbridge Road Bronx, NY 10468 GENERAL INFORMATION Title of Project: Zeiss OS/CIRRUS HD-OCT/VISUPAC Background: James J. Peters VA Medical Center is currently seeking to procure an Ocular Coherent Tomographer and Angiography equipment for the Eye Clinic located at the James J. Peters VA Medical Center. The Zeiss OCT and Visupac systems allow for multiple diagnostic tests for Macular Thickness, Retinal Vascularization and Macular Ischemia to name a few. Scope of Work: The contractor shall supply the government (specifically the James J. Peters VAMC) with a ZEISS OS/CIRRUS HD-OCT(model 5000 ) WITH Angioplex OCT Angiography and ZEISS OS/VISUPAC 500 WITH AUTOFLOURESCENCE. Zeiss OS/Cirrus HD-OCT/ Visupac 500 Specifications: Has the capability to have the ability to capture and provide OCT Angiography: This capability for OCT Angiography is provided by a 1 single OCT scan that allows for visualization of both micro vascular and structural information in an noninvasive dye free scan by the OCT. The unit must have exact Macular Scan Pattern of 512x128 for retina scan with exact scanning speed at 27,000 A-scans a second within a 6mmx6mm. Must be able to provide on Company Literature The unit must have exact scan pattern of 200x200 in a 6mmx6mm cube for Glaucoma Scan with exact scanning speed at 27,000 A-scans a second. The scan pattern must be able to capture and provide RNFL, ONH, Neuro Retinal Rim Tissue, and 3-D Cube capabilities all in one scan Scanning speeds: Scan at exactly 27,000 A-scans/sec, as well as the ability to scan at 68,000 A-scans/sec Unit must be able to provide a report for Ganglion Cell Analysis that is derived from a scan must be comprised of 6mmx6mm cube scan with a minimum by 200x200 line scan pattern with no more than 30 microns between each slice. Minimum Pupil Requirements must be 2.0mm or less. Unit must utilize an LSO Fundus Camera (Line Scanning Laser Ophthalmoscope).. The unit must Automatically Track to Prior Scan: The unit must be able to do this without technician needing to align to prior scan: Anterior Segment scan that is at minimal 15.5 mm in length x 5.8 mm in depth. which is the full view of the Anterior Chamber. Must be able to provide on Company Literature. Global Pachymetry report that is comprised of minimum of 24 radial scans and must be at a minimum 9mm in length. The unit must be a 90 degree configuration, so that the tech (operator) must sit to the side (90 degrees) of the pa OCT Imaging: Methodology - Spectral domain OCT Optical source - Superluminescent diode (SLD), 840 nm Scan speed - 27,000 A-scans per second or 68,000 A-scans per second* *All existing scan patterns in version 6.5 software will run at 27,000 A-scans per second, which is the same scan speed as the CIRRUS 4000. **All patient data from the Cirrus 4000 instrument can be transferred into the Cirrus 5000 seamlessly and used immediately for Guided Progression Analysis or any other Cirrus analytical program** A-scan depth - 2.0mm (in tissue), 1024 points Axial resolution - 5 um (in tissue) Transverse resolution - 15 um (in tissue) Cube scan pattern - 512 x 126 with over >67 million data ports and 47um spacing between lines Cube scan pattern - 200 x 200 with over >40 million data ports and 30um spacing between lines Fundus Imaging: Methodology - Line scanning ophthalmoscope (LSO) Live fundus image - during alignment and during OCT scan Optical source - Superluminescent diode (SLD), 750nm Field of view - 36 degrees Wx 30 degrees H Frame rate - >20 Hz Transverse resolution - 25 um (in tissue) Iris Imaging: Methodology - CCD Camera Resolution - 1280 x 1024 Live iris image - During alignment Electrical and Physical: Weight - 80 lbs. Dimensions of instrument - 26L x 18Wx 21H (in) Dimensions of table - 39L X 22W(in) Fixation: Internal fixation focus adjustment - -20D to +20D (diopters) Electrical rating (115V) - Single Phase, 100-120V~systems: 50/60Hz, 5A Electrical rating (230V) - Single Phase, 200-240V~systems: 50/60Hz, 2.5A Internal Computer: Operating system/processor - Windows 7, i& Intel processor Memory: Hard drive/internal storage - >=750 GB, > 80,000 scans Display - Integrated 19" color flat panel display USB ports - 6 ports 3. Performance Period: The contractor shall provide the deliverables required under this Statement of Need with in _15__ calendar days or less from date of award, unless otherwise directed by the Contracting Officer. The contractor shall provide a warranty period of 12 months after delivery and acceptance.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/VA/BroVANAP/VAMD/VA24217Q0564/listing.html)
 
Document(s)
Attachment
 
File Name: VA242-17-Q-0564 VA242-17-Q-0564.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=3438800&FileName=VA242-17-Q-0564-000.docx)
Link: https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=3438800&FileName=VA242-17-Q-0564-000.docx

 
Note: If links are broken, refer to Point of Contact above or contact the FBO Help Desk at 877-472-3779.
 
Record
SN04483261-W 20170426/170424235107-e3525ce1c8228365e6d5ae852ffc0a57 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.