DOCUMENT
65 -- 667-17-3-132-0410 GSI Audera DPOAE Audiology System - Attachment
- Notice Date
- 5/2/2017
- Notice Type
- Attachment
- NAICS
- 334510
— Electromedical and Electrotherapeutic Apparatus Manufacturing
- Contracting Office
- Department of Veterans Affairs;Overton Brooks VA Medical Center (90C);510 East Stoner Avenue;Shreveport LA 71101
- ZIP Code
- 71101
- Solicitation Number
- VA25617Q0667
- Response Due
- 5/11/2017
- Archive Date
- 8/9/2017
- Point of Contact
- Paul G Filhiol
- E-Mail Address
-
0-4088<br
- Small Business Set-Aside
- Veteran-Owned Small Business
- Description
- Combined Synopsis/Solicitation Announcement The Overton Brooks VA Medical Center in Shreveport, LA is issuing an Open Market RFQ IAW FAR 13.106 for Purchase of a GSI Audera Audiology System. This procurement is conducted under NAICS 334510 Electromedical and Electrotherapeutic Apparatus Manufacturing. This is a Total Veteran Owned Small Business (VOSB) Set-Aside IAW VAAR 852.219-11 VA Notice of Total Veteran-Owned Small Business Set-Aside.. In order to qualify for this set-aside, firms must be registered in the Vendor Information Pages at https://www.vip.vetbiz.gov/. Essential Specifications Test Types: Distortion Product Otoacoustic Emissions, Spontaneous OAE, Input/Output DPOAE Protocols: Default Diagnostic and Screening, Customer Configurable Display: DPgram, FFT plot, I/Ogram, Signal/ Noise Ratio of selected point, Compare Test (sequential test comparisons, multiple test, multiple days) Reports: Color, Black/White or PDF DPOAE Stimulus Tones: Frequency: 500 12, 000 Hz Level: 20 80 dB SPL, in 5 dB steps Accuracy: ± 3 dB Harmonic Distortion: < 1.8% at 80 dB SPL, IEC 711 coupler, 500 12,000 Hz Dynamic Range: 85 dB SPL, IEC 711 coupler, 500-12,000 Hz, F1 & F2 = 65 dB SPL Octave Ranges: 500-1000, 1000-2000, 2000-4000, 4000-8000, 8000-12000 Hz Points per Octave: 1 12 points F2/F1 Ratio: 1.1 1.8 Test Time: Varies, depending on test parameters, environment, and scoring options Status Indicators: Probe LED: - Green solid test in progress - Yellow solid seal check in progress - Yellow flashing test stopped, probe problem/ seal check failed OAE Pod/Probe: Dimensions: 1.69 (W) x 1.18 (D) x 4.17 (H) Weight:.44lb Interface to GSI Audera Base: 25 pin D-SUB connector Main Unit Computer Interface: USB - Type I T rigger Controls Input/Output: Standard TTL logic level Mains Power Supply: 115V, 110V, or 230V; 50-60 Hz Power Consumption: 115W, excluding printer Isolated Power: a) Main unit includes isolation transformer/ power supply which provides isolated mains power only for supported notebook computer and inkjet printer models. b) Main unit provides isolated power to Amplifier/Digitizer or Probe Unit. Dimensions: 12.99 (W) x 10.62 (D) x 1.67 (H) Weight: 7.05lb Environmental Limits: Operating Temp: 50 ° F to 104 ° F Relative Humidity: 30 to 75%, non-condensing Storage Temp: -40 ° F to 158 ° F Relative Humidity: 10 to 100%, non-condensing CPU Recommendation Operating System: Windows 7 Professional (32 bit & 64 bit), Windows XP Pro (SP3), Vista Business (SP2) Processor: 1.6 GHz Minimum RAM: 2 GB Storage: 11 GB Hard Drive Additional Storage: CD R/W drive US B Ports: 2 Graphics: 1024 x 768 pixels Compliance/Regulatory Standards Designed, tested and manufactured to meet the following domestic (USA), Canadian, European and International Standards: U L 60601-1 American Standards for Medical Electrical Equipment I EC 60601-1, EN 60601-1 International Standards for Medical Electrical Equipment CSA C22.2 # 601-1-M90 M edical Device Directive (MDD) to comply with EC Directive 93/42/EEC Part numbers are provided for the GSI Audera system components for illustrative and placeholder purposes. Equal items can be quoted if sufficient information for comparison is provided with the quote. The technically acceptable quote with the lowest price will obtain the award. This RFQ closes on 11 May 2017 at Noon Central Time. Quotes may be submitted via email to paul.filhiol@va.gov.
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/VA/ShVAMC/VAMCLAOBrooks/VA25617Q0667/listing.html)
- Document(s)
- Attachment
- File Name: VA256-17-Q-0667 VA256-17-Q-0667.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=3461917&FileName=VA256-17-Q-0667-000.docx)
- Link: https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=3461917&FileName=VA256-17-Q-0667-000.docx
- Note: If links are broken, refer to Point of Contact above or contact the FBO Help Desk at 877-472-3779.
- File Name: VA256-17-Q-0667 VA256-17-Q-0667.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=3461917&FileName=VA256-17-Q-0667-000.docx)
- Record
- SN04493362-W 20170504/170502235625-bfa46cfcd296cd7f4ce8254d0c6b6d0a (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |