Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY - FEDBIZOPPS ISSUE OF MAY 14, 2017 FBO #5651
SOURCES SOUGHT

49 -- Shipboard Micro Spotwelder

Notice Date
5/12/2017
 
Notice Type
Sources Sought
 
NAICS
333992 — Welding and Soldering Equipment Manufacturing
 
Contracting Office
Department of the Navy, Naval Air Systems Command, Naval Air Warfare Center Aircraft Division Lakehurst, Contracts Department, Hwy. 547 Attn:B562-3C, Lakehurst, New Jersey, 08733-5083
 
ZIP Code
08733-5083
 
Solicitation Number
N68335-17-R-0158
 
Archive Date
6/10/2017
 
Point of Contact
Richard J. Murphy, Phone: 7323232749
 
E-Mail Address
richard.j.murphy3@navy.mil
(richard.j.murphy3@navy.mil)
 
Small Business Set-Aside
N/A
 
Description
This is a Request for Information (RFI). There is currently no solicitation package available. The Naval Air Systems Command (NAVAIR) V-22 program is requesting information, comments, and questions regarding interest in a commercial or modified commercial Shipboard Micro Spotwelder. The government's specific interests are as follows: Interested companies who may have a single box solution commercially available. When responding to this configuration, please provide, Original Equipment Manufacturer (OEM) Part Number (P/N), general product information. Interested companies who have an existing single box capable of being modified to meet the specification as listed below. When responding to this configuration, please provide, OEM P/N, general product information on what the baseline model would be. Please forward any comments, questions, and concerns regarding the specification or general interest information to: Eric Murphy, Contract Specialist (732) 323-2749 All corporate and proprietary information should be so marked and will be fully protected to the extent allowed. This RFI is for planning purposes only and shall not be construed as a request for proposal or as an obligation on the part of the Government to acquire any follow-on acquisitions. Information should be submitted within 30 days of the publication date of this RFI. The Government does not intend to award a contract on the basis of this RFI or otherwise pay for the information solicited. No entitlement to payment of direct or indirect costs or charges by the Government will arise as a result of submission of responses to this RFI and Government use of such information. This RFI does not constitute the solicitation of proposals. Responders to this RFI may be requested to provide additional details/information based on their initial submittals. Questions and submissions may be submitted by email to richard.j.murphy3@navy.mil. Technical Requirements Capacitive discharge, dual pulse type spotwelder capable of applying welds to the following materials and thicknesses: •a) Inconel 600 sheet metal ranging from.002" to.025" thick •b) Titanium sheet metal up to.020" thick · The welder must be capable of producing welds no larger than 3/16" in diameter and shall be capable of reliably producing at least 30 of these welds per minute. · The micro spotwelder must be programmable with the ability to save program schedules (weld pulse parameters). · The micro spotwelder must be capable of operating on 110/120V AC, 60 Hz electrical power from a standard North American NEMA-type outlet. · The welder must be capable of table top use. It must have a total footprint of no more than 300 square inches. · The welder must be suitable for use with a pressure actuated, ergonomic, pistol grip type handheld welder handpiece. The applied pressure at which the welder discharges must be adjustable and capable of being set to fire at a pressure between 5 to 10 lbs. · Due to an intended operating environment below deck on US naval vessels, the micro spotwelder shall be capable of passing all tests listed in Table 1 below, per MIL-STD-461F, Requirements for the Control of Electromagnetic Interference Characteristics of Subsystems and Equipment, without adverse effects. Test No. Description CE101 30 Hz through 10 KHz, performed on input power leads. CE102 10 KHz through 10 MHz, performed on input power leads. CS101 30 Hz through 150 KHz, performed on input power leads. CS106 Conducted Susceptibility Transients performed on input power leads. CS114 10 KHz through 200 MHz, performed on input power and interconnecting cables. CS116 10 KHz through 100 MHz, performed on input power and interconnecting cables. RE101 30 Hz through 100 KHz, performed on all enclosures, power, and interconnecting cables. RE102 10 KHz through 1 GHz, performed on all enclosures, power, and interconnecting cables. RS101 30 Hz through 100 KHz, performed on all enclosures, power, and interconnecting cables. RS103 2 MHz through 18 GHz, performed at 10 v/m on all enclosures, power and interconnecting cables. Table 1: List of relevant EMI tests. Test procedures and requirements outlined in MIL-STD-461F.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/DON/NAVAIR/N68335/N68335-17-R-0158/listing.html)
 
Place of Performance
Address: Hwy. 547, Bldg. 562-3, Lakehurst, New Jersey, 08733, United States
Zip Code: 08733
 
Record
SN04507241-W 20170514/170512235327-5229bfb5fbcdeb81ff9e8f189688bb45 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |