59 -- Station Service Switchgear 480V, Fort Randal, SD

Notice Date
5/24/2017
 
Notice Type
Presolicitation
 
NAICS
335313 — Switchgear and Switchboard Apparatus Manufacturing
 
Contracting Office
Department of the Army, U.S. Army Corps of Engineers, USACE District, Omaha, Attn: CENWO- CT, 1616 Capitol Ave, Omaha, Nebraska, 68102-4901, United States
 
ZIP Code
68102-4901
 
Solicitation Number
W9128F-17-T-0066
 
Point of Contact
Timothy B. Boyte, Phone: 4029952069
 
E-Mail Address
timothy.b.boyte@usace.army.mil
(timothy.b.boyte@usace.army.mil)
 
Small Business Set-Aside
N/A
 
Description
Fort Randall Replace Interior 480V Station Service Equipment On or about 8 June 2017, this office will issue a Request for Proposals for the Replacement of Interior 480V Station Service Equipment for Fort Randall Dam, SD. The solicitation will close on or about 7 July 2017. This solicitation is for unrestricted, full and open competition. One contract is anticipated to be awarded from the solicitation. Drawings and all solicitation documents will be posted to the Federal Business Opportunities (FedBizOpps) website https://www.fbo.gov. All amendments will also be posted to this website. It shall be the contractor's responsibility to check the website for any amendments. The proposed shall submit all requested information specified in the proposal. There will be no public opening of the proposals received as a result of this solicitation. DO NOT submit requests for the proposals to the federal agency personnel. See Obtaining Solicitation Document below: Project Description: The scope of the project is to upgrade 6 existing 480 volt switchgear lineups and the replacement of two station service transformers located in the powerhouse. This is a general summary of the required work and is not all-inclusive. The upgrade of the Station Service include, but not necessarily be limited to the following: 1) Provide direct replacement or retrofill breakers (5 x 1600A & 94 x 600A) to replace power circuit breakers in the existing 480 VAC switchgear listed below. The replacement breakers will be modern design and required to be an off the shelf item requiring no housing modifications. a) 480 VAC Main Station Service Switchgear. b) 480 VAC Lighting Power Switchgear. c) 480 VAC Miscellaneous Power Switchgear 20. d) 480 VAC Common Auxiliary Switchgear. e) 480 VAC Intake Structure Switchgear. f) 480 VAC Spillway Structure Switchgear. 2) Replace station service transformer banks 2 and 4 with two new 1000 KVA 13.8kV/480V dry-type station service transformers. 3) Provide 2 new 15 kV feeder cables: a) Between switchyard station service circuit breaker 074 and station service transformer bank 4, disconnect 075. b) Between main unit circuit breaker 204 and station service transformer bank 2. 4) Test all existing feeder cables from the existing 480 VAC Switchgear listed in 1(a-f) above to the first point of termination. Perform insulation resistance (megger) tests on the power cables to verify their suitability for re-use. The existing power cables connected to the power circuit breakers will be retained unless testing indicates otherwise. 5) Provide spare circuit breakers (1 x 1600A & 5 x 600A), a remote racking device and spare parts for new retrofill circuit breakers as specified. 6) A complete bracing study will be performed to determine the adequacy of the existing bus within the 480 VAC Switchgear listed in 1(a-f) above. The bracing study will be performed to match the existing bus to the new breaker interrupting rating of 65 KA. 7) (OPTIONAL) Provide any and all bracing needed to rerate the existing 480 VAC Switchgear Buses to 65 KA. 8) Provide all necessary contractor commissioning activities and support Government Commissioning activities. 9) Prepare and furnish as-built drawings for the completed installation. 10) Prepare and furnish Operation and Maintenance (O&M) Manuals. Evaluation Criteria: Proposers: Please be advised of on-line registration requirement for Representations and Certifications Application (ORCA) which is located in System for Award Management (SAM) database https://www.sam.gov/portal/public/SAM/. Representations and certifications are required to be updated annually as a minimum to keep information current, accurate and complete. The electronic annual representations and certifications are effective until one year from date of submission or update to SAM. Obtaining Solicitation Documents: Solicitation documents will be posted to the web via Federal Business Opportunities (www.fbo.gov). Find solicitation announcement in FedBizOpps (www.fbo.gov) 1. Use the Quick Search to locate the project (by entering the solicitation number) or use the advanced search features offered in the Find Opportunities (large arrow in the middle of the page) or use the Opportunities tab followed by the Advanced Search tab. 2. By using the login feature, it allows additional search features and allows you to keep your searches. Login might be required on some solicitations that are considered restricted. 3. Once you have located your project, click on link to solicitation to view the project. Files may be downloaded from the column on the right side reading All Files or from the Packages tab. 4. If you want other vendors, sub-contractors or contractors to contact you, click on the Interested Vendors tab and then add me to Interested Vendors link at the bottom of the page. All written questions and/or comments should reach the Contracting Office referenced below no later than 16 June 2017 prior to the date set for receiving proposals so that they may be given consideration and/or actions taken prior to the receipt of proposals. Questions and answers will be posted to the FedBizOpps website by amendment on or about 30 June 2017. Telephone calls regarding Small Business matters should be made to: 402 995 2589. Contractual Point of Contact: US Army Corps of Engineers, Omaha District Timothy Boyte CENWO-CT-C 1616 Capitol Avenue Omaha, NE 68102-4901 (402) 995-2589 - Phone Timothy.b.boyte@usace.army.mil - E-Mail Contracting Office Address: USACE District, Omaha, 1616 Capital Ave, Omaha, NE 68102-4901 Place of Performance: USACE District, Omaha 1616 Capital Ave, Omaha NE 68102-4901 US Point of Contact(s): Timothy Boyte, 402-995-2589 USACE District, Omaha
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/USA/COE/DACA45/W9128F-17-T-0066/listing.html)
 
Place of Performance
Address: Fort Randall, Pickstown, South Dakota 57367, United States, Pickstown, South Dakota, 57367, United States
Zip Code: 57367
 
Record
SN04520613-W 20170526/170524235227-be4bcab8bc6f9f617293ee6030bc2892 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.