Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY - FEDBIZOPPS ISSUE OF MAY 26, 2017 FBO #5663
SOLICITATION NOTICE

Z -- Dole Courthouse 5th Floor Perimeter and Ground-Penthouse Interior Fire-Stopping

Notice Date
5/24/2017
 
Notice Type
Presolicitation
 
NAICS
236220 — Commercial and Institutional Building Construction
 
Contracting Office
General Services Administration, Public Buildings Service (PBS), Design and Construction Division (6PC), Acquisition Branch (6PCA), 1500 East Bannister Road, Kansas City, Missouri, 64131, United States
 
ZIP Code
64131
 
Solicitation Number
RKS11012_VKS00024
 
Archive Date
8/31/2017
 
Point of Contact
Charla R. Wells-Okoro, Phone: 816-823-5307, Jason Taylor,
 
E-Mail Address
charla.wells-okoro@gsa.gov, jason.taylor@gsa.gov
(charla.wells-okoro@gsa.gov, jason.taylor@gsa.gov)
 
Small Business Set-Aside
Service-Disabled Veteran-Owned Small Business
 
Description
General Information: The Robert J. Dole Federal Courthouse is an 8 story building with a ground floor, mezzanine and penthouse levels. A parking garage occupies a portion of Basement. The building contains 273,000 gross square feet and was completed in 1996 for the courts. The building is sprinklered and is provided with a fire alarm system. The building is located at 500 State Avenue, Kansas City, KS. Perimeter Firestopping: This project is a continuation of firestopping work performed on the lower levels of the Dole US Courthouse on floors Ground through 4th floors. The building perimeter firestopping in this project will be done at the 5th floor, with the 6th floor firestopping to be done in a separate project next year. The project started out as a project to seal up air infiltration that was occurring at the inside perimeter of the building. It was discovered that there were more or less continuous openings between floor slabs and exterior envelopes, at the perimeter. There was no floor-to-floor fire separation in these areas. The existing construction did not achieve the required 2-hour fire separation between floors. Perimeter firestopping details and techniques will be largely similar to those used on lower floors. In numerous instances, the method of achieving a suitable separation or fire rating can be achieved through the use of a standard UL Assembly or detail and firestopping material. In other instances, the method of achieving a suitable separation or fire rating cannot be achieved through the use of a standard assembly or detail. In such cases, an engineered solution and/or an engineering judgement needs to be developed by the fire protection engineer and the AHJ (authority having jurisdiction) has to approve the solution and the installation of the solution. Such customized engineered solutions require the utilization of a professional fire protection engineer on the design/construction team. Interior Firestopping: The building Interior firestopping in this work item will be done on all floors Ground through 6th. It was discovered that there were continuous openings between floor slabs on each floor typically within closets and chases and in firewalls, as well. There was no fire separation in these areas at these penetrations.. The existing construction did not achieve the required 2-hour fire separation between floors. In numerous instances, the method of achieving a suitable separation or fire rating can be achieved through the use of a standard UL Assembly or detail and firestopping material. In some cases, an engineered solution and/or an engineering judgement may need to be developed by the fire protection engineer and the AHJ (authority having jurisdiction) will have to approve the solution and the installation of the solution. All assemblies and engineered solutions will require the utilization of a professional fire protection engineer on the design/construction team.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/notices/148061a35a3832198e25b0ceac857c6b)
 
Place of Performance
Address: Robert J. Dole Federal Courthouse, 500 State Ave, Kansas City, Kansas, 66101, United States
Zip Code: 66101
 
Record
SN04521058-W 20170526/170524235716-148061a35a3832198e25b0ceac857c6b (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.