SOLICITATION NOTICE
66 -- 4 GHz High Definition Oscilloscope - Package #1
- Notice Date
- 5/24/2017
- Notice Type
- Combined Synopsis/Solicitation
- NAICS
- 334516
— Analytical Laboratory Instrument Manufacturing
- Contracting Office
- Department of the Air Force, Air Force Materiel Command, AFLCMC/PZIO - WPAFB, 1940 ALLBROOK DRIVE, WRIGHT-PATTERSON AFB, Ohio, 45433-5309, United States
- ZIP Code
- 45433-5309
- Solicitation Number
- FA86017T0058
- Archive Date
- 6/22/2017
- Point of Contact
- Donald G Loving, Phone: 9375224617, Toxie Courtney III, Phone: 937-522-4568
- E-Mail Address
-
donald.loving@us.af.mil, Toxie.Courtney.1@us.af.mil
(donald.loving@us.af.mil, Toxie.Courtney.1@us.af.mil)
- Small Business Set-Aside
- N/A
- Description
- Statement of Work - FA860117T0058 Commercial Solicitation - Oscilloscope FA860117T0058 Synopsitation FA860117T0058 Statement of Work 4 GHz High Definition Oscilloscope April 14, 2017 The Air Force Institute of Technology (AFIT) has a requirement for an Oscilloscope for Characterization of Pulsed Lasers to immediately support the institute's engineering graduate program. The requested oscilloscope should have the capability to detect electrical signals from ultra-fast detectors supporting an already-acquired Pico second laser source. The proposed oscilloscope will have a minimum of 4 GHz of bandwidth with at least 20 Gigasamples per second allowing a better characterization of the optical pulses leaving the laser and interacting with test samples. Minimum Requirements: A. Shall be compatible (as discussed in Paragraph B) with the following piece of equipment: a. Keysight DSOS404A High Definition Oscilloscope B. Oscilloscope for Characterization of Pulsed Lasers (Basic Requirements) 1. Shall have a minimum bandwidth of 4 GHz or better. 2. Shall have 4 analog channel inputs with Bayonet Neill-Concelman (BNC) inputs with Switchable input 3. Shall have a memory depth of 800 Mpts or larger. 4. Shall have a sample rate of 20 Gigasamples per second or faster. 5. Shall have a display size of 12 inches or larger 6. Shall have a waveform update rate of 700 waveforms per second or higher. 7. Shall have a noise floor of 800 uV RMS or better at 50 mV per division. 8. Shall have a rise time of 110 psec or faster. 9. 4 BNC-connected analog input probes for each analog input channel 10. Firmware updates for lifetime of oscilloscope shall be included. 11. Shall have software included necessary so users can reset oscilloscope and its operating system back to factory default. 12. Shall be capable of regular software updates available from original manufacturer. 13. Shall be able to store and output data files compatible with Matlab, Labview & Excel C. All components and modifications must include standard commercial warranties INSPECTION AND ACCEPTANCE: AFIT/ENP is designated as the office responsible for inspection and final acceptance of the supplies or services provided in this order. A receiving report shall be accomplished immediately upon receipt and acceptance of supplies. Acceptance of services will take place at the time of invoice certification. DELIVERY INSTRUCTION Location of Delivery: 88 MSG/LGRS BUILDING 257 5236 CHASE STREET WRIGHT-PATTERSON AFB OH 45433-5501 INVOICE AND PAYMENT: The contractor shall be paid upon submission of a properly prepared invoice (original and three copies) and after final inspection and acceptance has been made. A proper invoice shall cite the contractor's name and address, invoice number, invoice date, order number, contract line item number (CLIN), description of the supplies or service, unit of issue, unit price and extended price, terms of any prompt payment discount offered, and who to notify in the event the invoice is defective. The invoice shall be submitted to: The contractor shall submit invoice in wide area work flow (WAWF) as shown in this order schedule. Delivery Procedures Commercial Vehicles All vehicles larger than a large pick-up truck are required to be inspected by the Wright- Patterson Air Force Base Commercial Vehicle Delivery Gate (CVDG) prior to entering the installation. Vehicles to be inspected include, but are not limited to, the following: 1. Step van/panel truck 2. Tractor/trailer, box and flat bed containing cargo 3. Tanker trucks 4. Box trucks 5. Tour buses 6. Garbage/recycled waste trucks 7. Concrete trucks/mixers, dump trucks 8. Cranes, recreational vehicles, petroleum tanker This inspection will be conducted at Gate 16A located off State Route 444. The following are exemptions to vehicles utilizing the CVDG: 1. If the vehicle has the product inside (concrete and asphalt trucks) and timely delivery is necessary due to product deterioration it does not need to enter the CVDG. To bypass the CVDG, the contractor shall submit a list containing drivers' names, social security numbers and the state in which the driver's license is held for those drivers who will be entering the base. This shall be accomplished 24 hours prior to requested entry time. If entry is requested on Monday, this list must be submitted by Friday at 1630 hours. All lists shall be submitted to the 88th ABW/CE Directorate contract inspector. The only gates that may be used under this exemption shall be 15A, 26A, 38A, and gate 1B. If the driver's name is not on the list, he/she will not be allowed access to the installation through these gates and the base will not assume liability for denied access. 2. If a delivery vehicle must exit, and then re-enter the base to complete its route, the vehicle shall be resealed upon exiting the base. After initially passing through the commercial vehicle delivery gate, trucks shall be resealed at Gates 15A, 38A and 22B. The resealing of the trucks will allow them to continue to any other area of the installation (Areas A, B, or Kittyhawk) without reprocessing through the CVDG. To receive resealing assistance, the drivers shall physically stop at one of the three authorized gates and request the installation entry controller to reseal their truck and provide the next location of their delivery. The controller will reseal the truck and give the delivery driver a pre-clearance form. The driver shall present the pre-clearance form to the entry controller at the next point of installation entry. This reentry can be through any base gate. Vehicles may be subject to an inspection at any of installation entry control points during a directed random antiterrorism measure (RAM.) Any commercial vehicle, regardless of size, can be directed to the CVDG at the discretion of the installation entry controller.
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/USAF/AFMC/88 CONS/FA86017T0058/listing.html)
- Place of Performance
- Address: 88 MSG/SVMP, 2690 C Street, Bldg 571, Area B, WPAFB, Ohio, 45433, United States
- Zip Code: 45433
- Zip Code: 45433
- Record
- SN04521199-W 20170526/170524235830-3b87edf7dd3d6aca69f413cf777584d2 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |