Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY - FEDBIZOPPS ISSUE OF MAY 26, 2017 FBO #5663
SOLICITATION NOTICE

Z -- Replace Intake Motor Controls, Oahe Dam, SD

Notice Date
5/24/2017
 
Notice Type
Presolicitation
 
NAICS
237990 — Other Heavy and Civil Engineering Construction
 
Contracting Office
Department of the Army, U.S. Army Corps of Engineers, USACE District, Omaha, Attn: CENWO- CT, 1616 Capitol Ave, Omaha, Nebraska, 68102-4901, United States
 
ZIP Code
68102-4901
 
Solicitation Number
W9128F-17-B-0008
 
Archive Date
6/15/2017
 
Point of Contact
Jaimie K. Zurek, Phone: 4029952668
 
E-Mail Address
jaimie.k.zurek@usace.army.mil
(jaimie.k.zurek@usace.army.mil)
 
Small Business Set-Aside
N/A
 
Description
Federal Business Opportunities Information Date: 2017 May 24 SOLICITATION NO. W9128F-17-B-0008 On or about 15 June 2017, this office will issue Invitations for Bids for construction of the Replace Intake Motor Controls, Oahe Dam, SD. The solicitation will close on or about 17 July 2017. This solicitation is RESTRICTED TO SMALL BUSINESS PARTICIPATION. A site visit date and time will be issued with the advertisement package. DO NOT submit requests for plans and specifications to the site visit personnel listed above. See ‘Obtaining Solicitation Documents' below. _______________________________________________________________________________ Project Description: (Approx. quantities) This project is being performed on the intake gates at the Oahe Dam intake structure. The Oahe intake structure consists of a concrete superstructure with seven intake gates, bulkheads, trash racks and drop inlet shafts to penstocks that carry water to the power plant. The purpose of this project is to replace the electrical components of the intake gate controls. The main features of the work includes: motor controllers, limit switches, pushbutton stations, circuit breakers, safety interlocks and wiring. Additional requirements include programmable logic controllers with gate emergency lower bypass switch, encoders, and additional monitoring features for arc flash safety requirements. The components shall be purchased, assembled in new cabinets, and tested off-site by the contractor. The equipment shall then be transported and installed on-site. Installation is primarily in the intake structure with some components located in the power plant. The installation is dependent upon the power plant outage schedule, which is typically single unit outage during March-May and September-November of each year. Coordination with other ongoing projects that require outages will be needed. The old components shall be removed and disposed of at contractor expense. The estimated construction cost of this project is between $500,000 and $1,000,000. _______________________________________________________________________________ The Contractor will be required to commence work within 10 days after notice to proceed and complete the work 270 calendar days after receipt of Notice to Proceed. Provisions will be included for liquidated damages in case of failure to complete the work in the time allowed. Performance and payment bonds will be required. Bonding documents including the power of attorney shall bear an original signature by an officer of the surety. Bidders (Offerors): Please be advised of on-line registration requirement for Representations and Certifications Application (ORCA) is now located in System for Award Management (SAM) database https://www.sam.gov/portal/public/SAM/. Representations and certifications are required to be updated annually as a minimum to keep information current, accurate and complete. The electronic annual representations and certifications are effective until one year from date of submission or update to SAM. Obtaining Solicitation Documents: Solicitation documents will be posted to the web via Federal Business Opportunities (www.fbo.gov). Find solicitation announcement in Fed Biz Opps (www.fbo.gov) 1. Use the ‘Quick Search' to locate the project (by entering the solicitation number) or use the advanced search features offered in the ‘Find Opportunities' (large arrow in the middle of the page) or use the ‘Opportunities' tab followed by the ‘Advanced Search' tab. 2. By using the ‘login' feature, it allows additional search features and allows you to keep your searches. Login might be required on some solicitations that are considered restricted. 3. Once you have located your project, click on link to solicitation to view the project. Files may be downloaded from the column on the right side reading ‘All Files' or from the ‘Packages' tab. 4. If you want other vendors, sub-contractors or contractors to contact you, click on the ‘Interested Vendors' tab and then ‘Add me to Interested Vendors' link at the bottom of the page. Questions regarding contractual matters should be made to: Jaimie Zurek 402 995 2668. Telephone calls regarding Small Business matters should be made to: 402 995 2910. Telephone calls on contents of drawings and specifications should be made to the Project Manager at: 402-995-2468 or Specification Section at: 402-995 2184. U.S. Army Engineer District, Omaha ATTENTION: CENWO-CT-C 1616 Capitol Avenue Omaha, NE 68102 4901
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/USA/COE/DACA45/W9128F-17-B-0008/listing.html)
 
Place of Performance
Address: Pierre, South Dakota, 57501-6174, United States
Zip Code: 57501-6174
 
Record
SN04521282-W 20170526/170524235912-6338655de6a8aa7c45b7e15d8d4509da (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |