Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY - FEDBIZOPPS ISSUE OF JUNE 08, 2017 FBO #5676
SOURCES SOUGHT

58 -- Pre-Exit Telemetry Re-Transmission Amplifier (PETRA) GEN 2

Notice Date
6/6/2017
 
Notice Type
Sources Sought
 
NAICS
334220 — Radio and Television Broadcasting and Wireless Communications Equipment Manufacturing
 
Contracting Office
Department of the Navy, Naval Sea Systems Command, NSWC Corona Division, NSWC Corona Division, P.O. Box 5000, Corona, California, 92878-5000, United States
 
ZIP Code
92878-5000
 
Solicitation Number
N64267-17-T-0160
 
Archive Date
6/28/2017
 
Point of Contact
Luke J. Salazar, Phone: 9513935898, Graham M Conlon, Phone: 9513935106
 
E-Mail Address
luke.salazar@navy.mil, graham.m.conlon@navy.mil
(luke.salazar@navy.mil, graham.m.conlon@navy.mil)
 
Small Business Set-Aside
N/A
 
Description
This sources sought notice is being posted to satisfy the requirement under the Defense Federal Acquisition Regulation Supplement PGI 206.302-1(d). The Naval Surface warfare Center (NSWC), Corona Division intends to award on a sole source basis to Systems Engineering & Management Company 1430 Vantage Court Vista, Ca 92081 for the following: (6 ea) Pre-Exit Telemetry Re-Transmission Amplifier due to proprietary rights and data. This notice is published for informational purposes only and not a request for competitive proposals. However, all responsible sources may submit their technical capabilities, which if received by 26 May 2017, shall be considered by NSWC Corona. Responses must be submitted in writing to the procurement specialist, Luke Salazar, via email at luke.salazar@navy.mil no later than 12:00 pm PST on the date noted above. Email should reference Sources Sought Notice N64267-17-T-0160 in the subject. A determination by the Government not to compete this requirement based on responses to this notice is solely within the discretion of the Government. Information received will be considered solely for the purpose of determining whether to conduct a competitive procurement. ELECTRICAL Type Pre-Exit Telemetry Retransmission and Amplification System Frequency Band S Band (2200 MHz - 2395 MHz) Input Voltage 90 to 265 VAC (115/230 VAC auto ranging) Input Frequency 50 to 60 Hz Input/Output RF Impedance 50 ohms, 2:1 max VSWR PERFORMANCE RF Input level to activate Transmission No greater than -39 dBm Maximum Usable Linear Level 0 dBm Maximum input level without damage +10 dBm RF Input level to deactivate Transmission after it has already been activated (Hysteresis) No less than -43 dBm RF Output Level High Gain Mode 40 dBm Low Gain Mode 23 dBm RF Monitor Output 7 + 1 dB below RF input level (unamplified output) Two Tone, Third Order Inter-Modulation Distortion Product High Gain Mode No greater than 13dBm Low Gain Mode No greater than -27dBm Maximum Noise Level in a 1MHz Bandwidth -60 dBm Noise Suppression Circuit (Threshold enable/disable switch) Required to disable the output amplifier to prevent noise from being radiated when no signals above threshold are being transmitted Leveling Circuit Required to drive the output amplifier at a constant level and take care not to over drive or under drive the output at max power Self-Test Should include some kind of built in self-test capability to assure user of functionality ANTENNA Type Colinear Array Omnidirectional Narrow Beam Gain 8 dBi Polarization Type Vertical Beamwidth Azimuth OMNI (360 degrees) Elevation 15 degrees Connection 50 ohm N-type RF out Equipment 50 ft. low loss RF cable, and sturdy stainless steel pole mounts PHYSICAL Location All switches/connections/LED are required to be on one side similar to the current design. There should be consideration to the configuration of the PETRA installation. The current design allows for a "standing" installation or installation lying down on its side. We would like to retain these options. Switches Power On/Off switch, and High Gain/Low Gain switch, each with a cover to protect from accidental switching Connections Inputs AC Power MILSPEC locking connector, which includes weather-sealed 6ft power cable RF Two 50 ohm N-type connectors labeled FWD and AFT Outputs RF Antenna 50 ohm N-type connecter labeled ANT RF Monitor Two 50 ohm N-type connector labeled MON Indications Visual Two LED Indicators, POWER ON and TRANSMITTING Audio A loud audible tone to indicate system is transmitting Dimensions One side no greater than 8", two sides no greater than 12", Maximum volume of 1152 cubic inches Weight No greater than 30 lbs. ENVIRONMENTAL Operating Temperature 50 to 140 degrees F Relative Humidity 15 to 95% Storage Temperature -4 to 158 degrees F Material Ruggedized and resistant to heavy shock and vibration, water and EMI
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/notices/e243a5cef9f5bd51cb57a6b5903500cd)
 
Record
SN04534269-W 20170608/170606235633-e243a5cef9f5bd51cb57a6b5903500cd (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.