66 -- Ameri-Water R02 with high flow pump - - Attachment

Notice Date
6/6/2017
 
Notice Type
Attachment
 
NAICS
333318 — Other Commercial and Service Industry Machinery Manufacturing
 
Contracting Office
Department of Veterans Affairs;Overton Brooks VA Medical Center (90C);510 East Stoner Avenue;Shreveport LA 71101
 
ZIP Code
71101
 
Solicitation Number
VA25617N0817
 
Response Due
6/12/2017
 
Archive Date
8/11/2017
 
Point of Contact
Veronica Maskell
 
E-Mail Address
Veronica.Maskell@va.gov
(veronica.maskell@va.gov)
 
Small Business Set-Aside
N/A
 
Description
This is a Sources Sought/Market Research synopsis. The Overton Brooks VA Medical Center Contracting Office is performing Market Research to ascertain whether there are potential sources and their business size classification (HUB-Zone, 8(a), Small Business, Small Disadvantage Business, Women Owned Business, Service Disabled Veteran Owned Business, or Veteran Owned Business) relative to NAICS Code 333318 Other Commercial and Service Industry Machinery Manufacturing. The Medical Center is particularly interested in identifying Service Disabled Veteran Owned Small Business (SDVOSB) and their capability. The Medical Center is seeking potential sources to provide a Reverse Osmosis Water Treatment System and Storage Tank with the following technical specifications for the Alexandria VA Health Care System located at Pineville, LA 71306. The government is seeking the following products: DESCRIPTION AmeriWater RO2 with high flow pump and 100-gallon tank [Adding the blend valve(partAW00HCS5001) Part# AW00HCS2052 Water blend valve for AmeriWater Systems Part# AW00HCS5001 AmeriWater ROS with standard pump [Adding the blend valve (partAW00HCS5001) Part# AW00HCS2045 Water blend valve for AmeriWater Systems Part# AW00HCS5001 Salient Characteristics for Reverse Osmosis Water Treatment System and Storage Tank 1. Must provide low conductivity RO water for washers, disinfectors and final rinses at the deep sink to meet VA and industry standards. 2. Must have pretreatment filters, deionizer polisher and a 55 Gallon storage tank with demand pump that provides up to 800 gallons per day. 3. Must include a water purification monitor with audible alarm, low feed pressure system shutdown with alarm and high conductivity alarm. 4. Must have an empty tank pump shutdown. 5. Must be compatible with the existing Steris Reliance, Model 444 Single-Chamber Washer-Disinfector. 6. Installation required Installation must be a certified Steris representative to ensure proper installation up to the Steris 44 Single Chamber Washer Disinfector. The installation must be connected at the correct outlet ensuring that the existing hot and cold water not affected. Due to space limitations in the Decontamination room. The configuring cannot exceed the 86 X 30 footprint. NOTE: This notice is to assist the VA in determining sources only. This is not a solicitation for quotes. A solicitation will be issued at a later date and time. All information submitted in response to this source sought notice is considered voluntary. Interested and capable respondents are requested to provide: company name, address, point of contact, phone number, DUNS number, geographical location, business size and number of employees. Responses to this notice shall be e-mailed to Veronica Maskell, Contracting Specialist at e-mail address: veronica.maskell@va.gov. A telephone response will not be accepted. Responses must be received in writing no later than June 12, 2017, NLT 12pm CST.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/VA/ShVAMC/VAMCLAOBrooks/VA25617N0817/listing.html)
 
Document(s)
Attachment
 
File Name: VA256-17-N-0817 VA256-17-N-0817.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=3553287&FileName=VA256-17-N-0817-000.docx)
Link: https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=3553287&FileName=VA256-17-N-0817-000.docx

 
Note: If links are broken, refer to Point of Contact above or contact the FBO Help Desk at 877-472-3779.
 
Place of Performance
Address: Alexandria VA Health Care System;2495 Shreveport Hwy 71N;Warehouse Bldg 135;Pineville, LA
Zip Code: 71360
 
Record
SN04534760-W 20170608/170607000153-4a732c33c32bcca4ec8c23edf73a23b1 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.