Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY - FEDBIZOPPS ISSUE OF JUNE 10, 2017 FBO #5678
MODIFICATION

63 -- Surveillence System Upgrade

Notice Date
6/8/2017
 
Notice Type
Modification/Amendment
 
NAICS
561621 — Security Systems Services (except Locksmiths)
 
Contracting Office
Department of the Air Force, Air Force Materiel Command, AFLCMC / AFSC / AFNWC - HILL AFB, ., Hill AFB, Utah, 84056, United States
 
ZIP Code
84056
 
Solicitation Number
FA8201-17-Q-CP03
 
Archive Date
6/30/2017
 
Point of Contact
Christian Peal, Phone: 801-586-8882, Tyler Davidson, Phone: 801-777-7595
 
E-Mail Address
christian.peal.1@us.af.mil, tyler.davidson@us.af.mil
(christian.peal.1@us.af.mil, tyler.davidson@us.af.mil)
 
Small Business Set-Aside
Total Small Business
 
Description
I. Summary Contractor shall perform work necessary to supply and install parts for a surveillance camera system installation in and around buildings, 1926, 1927, 1930, and 1938 at the 729 th Air Control Squadron, Hill Air Force Base, Utah. For buildings 1926, 1927, and 1930, the security system shall be exterior installations only. (a) Contractor shall provide all labor, materials, equipment, transportation, and services required to accomplish all work related to installing equipment to manufactures specifications. (b) Contractor shall provide all necessary training to be able to utilize the camera system efficiently. II. Project Description (a) Contractor shall provide and install: (i) As Required - 2 Conductor 16 Gauge (19 X 29) Unshielded Speaker Cable 1. Building 1910 (i) Seven (7) each 8" Dual Cone Loudspeaker with 25V/70.7-5 Watt Transformer and Model 62-8 Baffle (ii) Three (3) each Horn Loudspeaker with 25V/70.7V/100V-15 Watt Transformer (iii) One (1) each Bi-Axial Horn, Gimbal-Mount, Twin Reflex Air Column (iv) One (1) each Compression Driver with 70.7V-30 Watt Transformer (v) One (1) each 100 Watt telephone paging amplifier 2. Building 1927 (i) Ten (10) each 8" Dual Cone Loudspeaker with 25V/70.7-5 Watt Transformer and Model 62-8 Baffle (ii) Three (3) each Horn Loudspeaker with 25V/70.7V/100V-15 Watt Transformer (iii) Two (2) each Bi-Axial Horn, Gimbal-Mount, Twin Reflex Air Column (iv) Two (2) each Compression Driver with 70.7V-30 Watt Transformer (v) One (1) each 100 Watt telephone paging amplifier 3. Building 1930 (i) Two (2) each 8" Dual Cone Loudspeaker with 25V/70.7-5 Watt Transformer and Model 62-8 Baffle (ii) Two (2) each Horn Loudspeaker with 25V/70.7V/100V-15 Watt Transformer (iii) One (1) each 35 Watt Mixer-Amplifier 4. Building 1938 (i) Ten (67) each 8" Dual Cone Loudspeaker with 25V/70.7-5 Watt Transformer and Model 62-8 Baffle (ii) Seven (7) each Horn Loudspeaker with 25V/70.7V/100V-15 Watt Transformer (iii) Two (2) each Bi-Axial Horn, Gimbal-Mount, Twin Reflex Air Column (iv) Two (2) each Compression Driver with 70.7V-30 Watt Transformer (v) One (1) each 250 Watt telephone paging amplifier (vi) One (1) each Single-zone universal telephone interface (24V) (vii) Two (2) each Line Level Distribution Amplifier - 1x3 (viii) One (1) each RDL Automatic Ducking Module (ix) Three (3) each 24Vdc Switching Power Supply, North American AC Plug, 500 mA, dc Plug b) Replace all current speakers and horns in buildings 1910 and 1938; Building 1910 - Seven (7) 8" Dual Cone Loudspeaker with 25V/70.7-5W Transformer and Model 62-8 Baffle, Three (3) Horn Loudspeaker with 25V/70.7V/100V-15W Transformer. Building 1938 - Sixty-Seven (67) 8" Dual Cone Loudspeaker with 25V/70.7-5W Transformer and Model 62-8 Baffle, Seven (7) Horn Loudspeaker with 25V/70.7V/100V-15W Transformer. (c) Install the following on the exterior of buildings listed below; Building 1910 - Install One (1) Bi-Axial Horn, Gimbal-Mount, Twin Reflex Air Column Building 1927 - Install Two (2) Bi-Axial Horn, Gimbal-Mount, Twin Reflex Air Column Building 1938 - Install Two (2) Bi-Axial Horn, Gimbal-Mount, Twin Reflex Air Column (d) All installed paging equipment shall be able to be utilized by any of the currently installed Cisco phones that are installed and shall be part of the current "3-5-7" VOIP accessed paging system. (e) There must be at a minimum of one 8" Dual Cone Loudspeaker with 25V/70.7-5W Transformer and Model 62-8 Baffle installed in each of the restrooms located in each building
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/USAF/AFMC/OOALC/FA8201-17-Q-CP03/listing.html)
 
Place of Performance
Address: 729 Air Control Squadron (729 ACS), 6475 Warrior Way | Bldg 1938, Hill Air Force Base, Utah, 84056, United States
Zip Code: 84056
 
Record
SN04538504-W 20170610/170608235651-075fec21da6efef9b618e20cd2a89aa2 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.