AWARD
Z -- Bldg #268 Fire Alarm
- Notice Date
- 6/9/2017
- Notice Type
- Award Notice
- NAICS
- 236220
— Commercial and Institutional Building Construction
- Contracting Office
- Department of the Army, Army Contracting Command, MICC, MICC - Fort Leavenworth, 535 Kearny Ave, Bldg 338, Fort Leavenworth, Kansas, 66027, United States
- ZIP Code
- 66027
- Solicitation Number
- W91QF4-17-R-0029
- Archive Date
- 6/23/2017
- Point of Contact
- Robert M. Parvin, Phone: 913-684-1625, Alphonso Barnes Jr, Phone: 9136841643
- E-Mail Address
-
robert.m.parvin.civ@mail.mil, alphonso.barnes3.civ@mail.mil
(robert.m.parvin.civ@mail.mil, alphonso.barnes3.civ@mail.mil)
- Small Business Set-Aside
- N/A
- Award Number
- W91QF4-15-G-0002-0010
- Award Date
- 6/8/2017
- Awardee
- Vazquez Commercial Construction, 3303 Gillham Road, Kansas City, Kansas 64109, United States
- Award Amount
- $187,692.24
- Line Number
- 0001-0003
- Description
- This order is issued under and pursuant to the provisions of W91QF4-15-G-0002 (the "Agreement"). The terms and conditions of the Agreement are hereby incorporated by reference and, except as provided herein by this order, remain in full force and effect. Authority: The Contracting Officer sites 10 U.S.C. 2304(c) (5) as the authority for use of other than full and open competition for an 8a Sole Source Award. In coordination with the SBA, MICC - Fort Leavenworth offers BOA Task Orders to fulfill SRM construction requirements to eligible 8a SB Concerns IAW FAR Subpart 19.804-5. This is a Sole Source 8a award made under the DOD/SBA Partnership Agreement (PA) - provided under the authority of DFARS Subpart 219.8 and clause 252.219-7009 for Section 8(a) Direct Award. Replace Fire Alarm System and Miscellaneous HVAC items. Repair Fire Alarm System a. Replace existing Fire Alarm System with a new Fire Alarm System that meets all current UFC, NFPA, NFC and NEC applicable codes. The fire alarm system shall be addressable and include notification devices, supervise the sprinkler system and report directly to the emergency dispatch center through the LCIDS system both wireless and over network. Provide final project plans reviewed by and stamped by a P.E. Demolition Items in Basement a.Remove all flexible electrical conduit, electrical outlets, and wire that was located in walls and ceilings back to panel board. b. Demo all Data and Communications wiring back to origination. c. Remove and salvage lights in basement (which are not located in mechanical room and latrines). Demo unused electrical conduit and wiring. HVAC Miscellaneous Items a. Remove fan coils located in basement, remove fan coils located in each bathroom with associated plumbing risers connected from basement. Disconnect fan coil piping from main HVAC piping and replace with press fittings for supply, return and condensate piping. b. Install new electric unit heaters in each bathroom. c. Install new fiberglass insulation on HVAC piping located in basement. d. Disconnect all control wiring to existing fan coils in basement. Salvage control boards and room sensors to turn into government.
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/notices/71c086be69177f3c95edbed2791e838a)
- Record
- SN04539836-W 20170611/170609234755-71c086be69177f3c95edbed2791e838a (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |