H -- GLA - Perform Annual & Semi Annual - Boiler Plant Safety Device Testing - Attachment

Notice Date
6/12/2017
 
Notice Type
Attachment
 
NAICS
238220 — Plumbing, Heating, and Air-Conditioning Contractors
 
Contracting Office
Department of Veterans Affairs;Network Contracting Office 22;4811 Airport Plaza Drive;Suite 600;Long Beach CA 90815
 
ZIP Code
90815
 
Solicitation Number
VA26217N1128
 
Response Due
6/15/2017
 
Archive Date
6/30/2017
 
Point of Contact
Alejandro M. Gonzalez, Contract Specialist
 
Small Business Set-Aside
N/A
 
Description
This is a SOURCES SOUGHT ANNOUNCEMENT ONLY. The purpose of this sources sought announcement is for market research purposes to gain knowledge of potential qualified sources and their SBA size classification in relation to NAICS 238220. Documentation of technical expertise must be presented in sufficient detail for the Government to determine that your company possesses the necessary functional area expertise and experience to compete for this acquisition. Responses to this notice shall be in writing and include the following: Company name Address Point of contact Phone, fax, and email DUNS number Cage Code Tax ID Number Type of small business, e.g. Services Disabled Veteran Owned Small Business (SDVOSB), Veteran Owned Small Business (VOSB), 8(a), HUBZone, Women Owned Small Business (WOSB), Small Disadvantaged Business, or Small Business [NOTE: If you are a SDVOSB or VOSB, you must submit your certification from the Center for Verification and Evaluation (CVE) (https://www.vip.vetbiz.gov/)], Must provide a capability statement that addresses the organizations qualifications and ability to perform as a contractor for the work described below Provide any certifications, licenses and /or other pertinent documents/evidence that is required to perform the requested services. If possible, provide an estimate price for the request service below. Please provide previous or current works that are in similar size, and complexity as the Government requirement. All Offerors who provide goods or services to the United States Federal Government must be registered in the System for Award Management (SAM) database found at https://www.sam.gov. Registration must include Representations and Certifications. Additionally, all Service Disabled Veteran Owned Businesses or Veteran Owned Business who respond to a solicitation on this project must be registered and verified with the Vet Biz Registry located at http://vip.vetbiz.gov. After review of the responses to this sources sought synopsis, a solicitation announcement may be published to www.FBO.gov. Responses to this sources sought synopsis are not considered adequate responses to solicitation notice. The Department of Veterans Affairs, Network Contracting Office (NCO) 22, is seeking a source for establishing a contract to provide services in support of the VA Greater Los Angeles Healthcare System (VAGLAHS) Engineering Department to perform all testing in accordance with the VHA Boiler Safety Device Testing Manual (Third Edition) and VACO Directive 1810. The period of performance shall be for one year from the date of award. Testing is due every six months (semiannual and annual) and shall be performed within 30 days for each period. Contractor is responsible for all manpower and materials required. Contractor is responsible for any adjustments necessary to achieve compliance and continuous reliable operation. Contractor is responsible for Determining the Safety Device set point and normal operating range and affix label prior to test. Contractor shall perform hydrostatically test on boilers and their economizers to determine if there is internal failure. Contractor shall perform Safety Device Testing on Boilers. Contractor shall perform Safety Device Testing on DA Tank. Contractor shall perform Safety Device Testing on Condensate Tank. Contractor shall perform Safety Device Testing on Other Plant Safety Devices. Contractor shall affix calibration and test stickers to each device upon conclusion of test. Contractor shall provide hard and electronic copies of all testing results and reports including binder using forms from the Safety Device Testing Manual to the COR within 7 days of testing. 1. WEST LOS ANGELES 2.2. VHA Safety Device Testing Manual 2.2.1. Contractor must ensure safety device is located in correct place 2.2.2. Contractor must ensure safety device set point is correct 2.2.3. Contractor must ensure safety device activates at the correct set point 2.2.4. Contractor must ensure safety device produces the required effect 3. EQUIPMENT TO BE TESTED 3.1. BOILERS INFORMATION i. Boiler #1 Babcock and Wilcox National Board# - 24554 ii. Boiler #2 Babcock and Wilcox National Board# - 24551 iii. Boiler #4 Babcock and Wilcox National Board# - 24552 3.1.1. For the boilers listed above in paragraph 3.1, contractor shall inspect, calibrate and test the following: Special note for items with * or **: *Indicates combination switch/gauge. Gauges are to be zeroed and calibrated prior to test. Air shall be purged from lines after completion of test. **To be performed prior to relevant test 3.1.2. Check gas vent valves for leaks (main and pilot, gas and propane) 3.1.3. High gas pressure cutout* 3.1.4. Low gas pressure cutout* 3.1.5. Safety Shutoff Valves proof of closure (gas) 3.1.6. Leak test safety shutoff valves (gas) 3.1.7. High oil pressure cutout* 3.1.8. Low oil pressure cutout* 3.1.9. Low atomizing pressure cutout* 3.1.10. Oil burner position switch 3.1.11. Safety Shutoff Valves proof of closure (oil) 3.1.12. Leak test safety shutoff valves (oil) 3.1.13. Oil pump liquid relief valves (2) 3.1.14. Low pilot pressure cutout (gas/propane)* 3.1.15. Adjust propane and natural gas pilot flame** 3.1.16. High steam pressure cutout* 3.1.17. Auxiliary high steam pressure cutout* 3.1.18. Steam safety valves 3.1.19. High water alarm 3.1.20. Low water alarm 3.1.21. Low water cutout 3.1.22. Low water cutout shunt switch 3.1.23. Auxiliary low water cutout 3.1.24. Auxiliary low water cutout shunt switch 3.1.25. Forced draft fan motor interlock 3.1.26. Forced draft fan purge position switches (high/low) 3.1.27. FGR fan purge position switches (high/low) 3.1.28. Purge air flow switch* 3.1.29. Time for pre purge 3.1.30. Time for post purge 3.1.31. Igniter timing 3.1.32. Combustion air flow switch* 3.1.33. Main flame failure time to close valves 3.1.34. Igniter flame failure time to close valves 3.1.35. Flame scanner 3.1.36. Flame scanner not sensing ignition spark 3.1.37. Low O2 alarm and cutout 3.1.38. Low instrument air pressure cutout* 3.1.39. Economizer liquid relief valve 3.1.40. Calibrate draft gauges (4) 3.2. DA TANK 3.2.1. DA TANK INFORMATION: i. South Gate Engineering Serial # 23071 (TOP) ii. South Gate Engineering Serial # 23070 (BOTTOM) 3.2.2. For the da tank listed in paragraph 3.2.1, contractor shall inspect, calibrate and test the following: 3.2.3. High water alarm 3.2.4. Auxiliary high water level alarm 3.2.5. Low water alarm 3.2.6. Auxiliary low water level alarm 3.2.7. Overflow valve 3.2.8. Safety valve 3.2.9. PRV safety valve 3.2.10. Calibrate/test Pressure sensors and gauges on steam PRV and Tanks 3.3. CONDENSATE TANK 3.3.1. CONDENSATE TANK INFORMATION: i. Downey Welding and Manufacturing Co Serial #1350 3.3.2. For the condensate tank listed in paragraph 3.3.1, contractor shall inspect, calibrate and test the following: 3.3.3. High water alarm 3.3.4. Low Water alarm 3.3.5. Auxiliary low water alarm 3.4. OTHER PLANT SAFETY DEVICES 3.4.1. For all other plant safety devise, contractor shall inspect, calibrate, and test the following: 3.4.2. Test and Calibrate Toxic Gas System (Methane / LEL and CO ) MSA Gasgard G (8sensor 2 strobes) 3.4.3. Test and Calibrate Ammonia Detection System - MSA Gasgard XL (4 sensors, 2 strobes, 2 handheld units) 3.4.4. Emergency Fuel Shutdown System Automation Direct/Allen Bradley (5 station) 3.4.5. Low Main Gas Pressure Switch (Dwyer) 3.4.6. Low Condensate Pressure Switch (Dwyer) 3.4.7. Low Incoming Water Pressure Switch (Dwyer 2) 3.4.8. Low Main Feed Switch (Dwyer) 3.4.9. Low Plant Air Pressure Switch (Dwyer) 3.4.10. Main Steam Header Pressure (Dwyer) 3.4.11. Emergency Back Up Well System After reviewing this notice and believe that your firm can provide the requested services, please submit the information as outlined in the first paragraph. Responses to this notice shall be emailed to the attention of Alejandro M. Gonzalez at Alejandro.gonzalez2@va.gov and with the following information in the subject line of the email: VA262 17 N 1128 GLA (Perform Annual & Semi Annual - Boiler Plant Safety Device Testing). Telephone responses will not be accepted. Responses must be received no later than June 15, 2017, 2:30 PM Pacific Daylight Time (PDT). Important information: The Government is not obligated to nor will it pay for or reimburse any costs associated with responding to this sources sought synopsis request. This notice shall not be construed as a commitment by the Government to issue a solicitation or ultimately award a contract, nor does it restrict the Government to a particular acquisition approach. The Government will in no way be bound to this information if any solicitation is issued.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/VA/LBVANBC/VAMD/VA26217N1128/listing.html)
 
Document(s)
Attachment
 
File Name: VA262-17-N-1128 VA262-17-N-1128.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=3575542&FileName=VA262-17-N-1128-000.docx)
Link: https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=3575542&FileName=VA262-17-N-1128-000.docx

 
Note: If links are broken, refer to Point of Contact above or contact the FBO Help Desk at 877-472-3779.
 
Place of Performance
Address: VA GLA Medical Center;11301 Wilshire Blvd;Los Angeles, CA 90073
Zip Code: 90073
 
Record
SN04540750-W 20170614/170612234509-c80b417c3388626d3bd4f7a302c0958b (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.