DOCUMENT
Y -- Refurbish Bone Marrow Unit Project No 674-15-100 - Attachment
- Notice Date
- 6/14/2017
- Notice Type
- Attachment
- NAICS
- 236220
— Commercial and Institutional Building Construction
- Contracting Office
- Department of Veterans Affairs;Network Contracting Office, NCO17;Central Texas Veterans HCS;2002 Scott Blvd;Temple TX 76504
- ZIP Code
- 76504
- Solicitation Number
- VA25717B0252
- Response Due
- 4/18/2017
- Archive Date
- 7/26/2017
- Point of Contact
- Joyce M Mills
- E-Mail Address
-
9-6026<br
- Small Business Set-Aside
- Service-Disabled Veteran-Owned Small Business
- Award Number
- VA257-17-C-0123
- Award Date
- 6/13/2017
- Awardee
- HAMILTON PACIFIC CHAMBERLAIN, LLC;101 PAUL MELLON CT UNIT 3;WALDORF;MD;20602
- Award Amount
- $1,480,999.74
- Description
- NOTICE OF CONTRACT AWARD resulting from solicitation: VA257-17-B-0252: Network Contracting Office, NCO17, has awarded a Firm Fixed Price Construction Contract, VA257-17-C-0123, Refurbish Bone Marrow Unit, in the amount of $1,480,999.74; to Hamilton Pacific Chamberlain, LLC 14 K Irongate Drive, Waldorf, MD 20602. Project consists of, but is not limited to; Contractor shall provide all necessary labor, materials, equipment, tooling, and supervision to perform all requirements of the resulting contract. The project includes, but is not limited to the following; contractor shall furnish all labor, materials, tooling, equipment, supervision to construct the area located on the seventh floor Bone Marrow Ward, repair (vice replace as shown in Add Alternate) air handler unit (AHU-72A) to include exhaust fan and replace chilled water control valve serving AHU-72A at Audie L. Murphy Memorial Veterans Hospital. The Construction Documents shall include drawings for replacing existing Bone Marrow Ward finishes to include Walls, Flooring, Ceilings, Lighting, Registers and Returns, Crash Guards, Transition Strips, Corner Guards, Wood Doors and Metal Frames, Door Hardware Hinges, Closures and Locksets, Kick Plates and Door Protection in all Patient Rooms, Patient Rooms Restrooms, Restrooms, Director s Office, Conference Room, Physician s Assistant Office, Social Worker Office, Nurse Manager s Office, Medication Room, Nurses Station, Men s and Women s Locker Rooms, Pharmacy Workroom, Staff Restroom, H.A.C., Dirty Utility, Clean Utility, Ward & Main Corridor, Waiting Room and all Offices. New lighting ballast shall be able to accommodate LED bulbs. Due to continuous issues with heating and cooling on both ends of unit; contractor shall renovate and construct according to the plans including demolition, abatement and new work, specifications for architectural, mechanical, plumbing, electrical and structural for repairing air handling unit seventh floor interstitial. The Base Bid shall also include the installation of a Variable Frequency Drive (VFD) for the existing exhaust fan EXF-7-2A and a complete Air Balance Schedule. The new VFD will adjust the fan outlet CFM and help in balancing EXF-7-2A and the Bone Marrow Ward and Sleep Lab exhaust. A full air balance shall be performed once the new fan VFD has been installed. The existing chilled water control valve serving AHU-72A shall be replaced under Base Bid and Bid Add Alternate #1 shall include replacement (vice repair as shown in base bid) of AHU-72A and all associated work as listed in Base Bid above in addition to the following: AHU-72A will include an Energy Recovery Wheel requiring existing exhaust fans (EXF-7-2A and 1-EF1) and ductwork to be removed. New return/exhaust ductwork will be installed within the interstitial space connecting all return/exhaust ventilation from the Bone Marrow Ward and Sleep Lab and exhausting it through AHU-72A Energy Recovery Wheel. The new AHU shall include a hot water coil in lieu of the existing steam coil that was previously installed within AHU-72A. The existing steam heating piping will be removed to provide space for the new Steam to Hot Water Heat Exchanger and Hot Water Circulator Pump. Steam will still be required to provide humidification within the unit. Existing equipment, ductwork and piping will be removed or offset to provide space for the new equipment and piping. Project duration shall be 270 calendar days from NTP issuance for the Base Bid work. **NOTE: For Subcontracting opportunities, please contact the Prime Contractor Hamilton Pacific Chamberlain, LLC 14 K Irongate Drive, Waldorf, MD 20602. Phone No. 301-632-6623 or email: griffin@hpcvet.com>
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/VA/VACTHCS674/VACTHCS674/VA25717B0252/listing.html)
- Document(s)
- Attachment
- File Name: VA257-17-C-0123 VA257-17-C-0123_1.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=3583068&FileName=VA257-17-C-0123-000.docx)
- Link: https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=3583068&FileName=VA257-17-C-0123-000.docx
- Note: If links are broken, refer to Point of Contact above or contact the FBO Help Desk at 877-472-3779.
- File Name: VA257-17-C-0123 VA257-17-C-0123_1.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=3583068&FileName=VA257-17-C-0123-000.docx)
- Record
- SN04544134-W 20170616/170614234744-36f9ad2e2cf3471b3e75e0b31ce7de56 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |