DOCUMENT
65 -- 580-17-2-167-0218-Electroencephalograph (EEG) Sys-VA256-17-AP-4600 - Attachment
- Notice Date
- 6/19/2017
- Notice Type
- Attachment
- NAICS
- 339112
— Surgical and Medical Instrument Manufacturing
- Contracting Office
- Department of Veterans Affairs;Acquisition & Materiel Management;Michael E. DeBakey VA Medical Center;2002 Holcombe BLVD;Houston TX 77030 4298
- Solicitation Number
- VA25617N0915
- Archive Date
- 6/29/2017
- Point of Contact
- kever.swafford@va.gov
- Small Business Set-Aside
- N/A
- Description
- Sources Sought Notice: Electroencephalograph (EEG) System DESCRIPTION: This is a sources sought to determine the availability of potential sources having the skills and capabilities necessary to provide the SPECIFIED REQUIREMENT. All interested vendors are invited to provide information to contribute to this market survey/sources sought including commercial market information. THIS IS NOT A SOLICITATION ANNOUNCEMENT. This is a sources sought synopsis only. Questions shall be submitted by email to kever.swafford@va.gov Provide only the requested information below. The purpose of this sources sought is to gain knowledge of potential qualified sources and their size classifications (Service Disabled/Veteran Owned Small Business (SDVOSB/VOSB), Hub zone, 8(a), small, small disadvantaged, woman owned small business, FSS/GSA contract schedule holders or large business) relative to NAICS Code 339112, Surgical and Medical Instrument Manufacturing to this sources sought will be used by the Government to make appropriate acquisition decisions. After review of the responses to this sources sought synopsis, a solicitation announcement may be published on the GSA or FBO website. Responses to this sources sought synopsis are not considered adequate responses to the solicitation announcement. All interested offerors will have to respond to the solicitation announcement in addition to responding to this sources sought announcement. The Michael E. DeBakey VA Medical Center is seeking information about the capabilities of potential third party companies to furnish the following: Natus Neurology Xltek Ambulatory Electroencephalograph (EEG) System Number...................................................................................................... PK1055HD Use Cases..............................................................................Clinical EEG, PSG, Ambulatory Analog Specifications - AC Channels Referential Channels......................................................................................................24 Differential Channels.......................................................................................................4 Maximum Differential AC Input Before Clipping (Referential)....................20 mV pk-to-pk Maximum Differential AC Input Before Clipping (Differential)...................20 mV pk-to-pk Common Mode Rejection Ratio.............................................................. -113 dB @ 60 Hz DC Removal........................................................................................................ ±500 mV Common Mode Input Impedance...................................................................> 10 MOhms Input Noise (peak to peak).......................................................................................6.4 V Input Noise (RMS)................................................................................................. 1.08 V Input Bias Current................................................................................................. < 10 pA Channel Crosstalk....................................................................................................-56 dB Electrode Connections (including common input)...............................................Touchproof Digital Specifications Sampling Resolution Referential Channels.............................................................. 16 bits Sampling Resolution Differential Channels............................................................. 16 bits Sampling Resolution DC Channels.......................................................................... 16 bits Analog Specifications DC Channels DC Channels (patient side)............................................................................ 4 non-isolated DC Input Range......................................................................................................... ± 5 V Modes of Operation Impedance (kOhm)............................................................................. <2.5, <5, <10, <25 Channel Test Signal........................................................................... Software Controllable Square................................................................................ 0.25-1 Hz, 125 V pk-to-pk Sampling Frequency.......................................................................200 Hz, 256 Hz, 512 Hz Wireless Specifications Protocol...............................................................................................Bluetooth V2.0 EDR Operating Frequency................................................................................ 2.40 2.48 GHz Transmission Power................................................................................................20dBm Modulation................................................................................................................GFSK FCCID............................................................................................................R47F2M03GL User Interface Event Switch Connection.................................................................................. 1 on board Other Connections............................................Nonin Xpod ® Oximeter or Photic Stimulator PC Interface Direct.....................................................................................................................USB 2.0 Amplifier Mechanical Approximate Size................................................. 3.94 x 6.1 x 0.98 in / 10 x 15.5 x 2.5 cm Weight........................................................................................................ 0.56 lb / 255 g Operating Parameters Operating Environmental Limits Temperature..............................................................................................10 °C to 40 °C Humidity........................................................................................................30%-75% Atmospheric Pressure....................................................................... 700 hpA-1060 hpA Transport and Storage Temperature Range..................................................-40 °C to 70 °C Transport and Storage Humidity Range.......................10%-100%, including condensation Transport and Storage Atmospheric Pressure Range............................. 500 hPa-1060 hPa Regulatory Compliance CAN/CSA C22.2 No 601.1-M90, UL 60601-1, IEC 60601-1, IEC 60601-1-1, IEC 60601-2-26, IEC 60601-1-4, IEC 60601-1-6, IEC 60601-1-2, CISPR 11/EN 55011, FCC 47 CRF Part 15 Technical REQUESTED INFORMATION: (1) STATEMENT OF CABABILITY: Submit a brief description, five (5) pages or less, that demonstrates how your company has the supervision, facilities, labor and experience to provide Electroencephalograph (EEG) System as described above. Include past experience in performing these services to the VA, other Government (Federal or State) agency, or for a private facility. Please specify your availability to start date and your address. (2) BUSINESS SIZE AND SOCIO-ECONOMIC STATUS: (a) Indicate whether your business is large or small (b) If small, indicate if your firm qualifies as a small, emerging business, or small disadvantaged business (c) If disadvantaged, specify under which disadvantaged group and if your firm is certified under Section 8(a) of the Small Business Act (d) Indicate if your firm is a certified Hub-zone firm (e) Indicate if your firm is a woman-owned or operated business (f) Indicate if your firm is a certified Service-Disabled Veteran Owned Small Business (SDVOSB) or Veteran Owned Small Business (VOSB) (g) Include the DUNS number of your firm. (h) State whether your firm is registered with the System for Award Management (SAM) at https://www.sam.gov/portal/public/SAM/ and/or the VetBiz Registry at http://vip.vetbiz.gov/. (i) NOTE that any future solicitation could only be awarded to a contractor who is registered in SAM and to receive award based on VOSB or SDVOSB status you must be registered in the VetBiz Registry. Responses shall be submitted by email to kever.swafford@va.gov, no later than 11:30am CST, June 23, 2017. Fax or Telephone calls will not be accepted. Your response should include both the STATEMENT OF CABABILITY and BUSINESS SIZE AND SOCIO-ECONOMIC STATUS information as explained above. Please place "Attention: Electroencephalograph (EEG) System VA256-17-N-0915 in the subject line of your response. This notice is to assist the VA in determining sources only. A SOLICITATION IS NOT CURRENTLY AVAILABLE AND MAY NOT DEVELOP FROM THIS RFI. If a solicitation is issued it will be announced at a later date and all interested parties must respond to that solicitation announcement separately from the responses to this announcement.
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/VA/HoVAMC/VAMCCO80220/VA25617N0915/listing.html)
- Document(s)
- Attachment
- File Name: VA256-17-N-0915 VA256-17-N-0915.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=3593183&FileName=VA256-17-N-0915-000.docx)
- Link: https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=3593183&FileName=VA256-17-N-0915-000.docx
- Note: If links are broken, refer to Point of Contact above or contact the FBO Help Desk at 877-472-3779.
- File Name: VA256-17-N-0915 VA256-17-N-0915.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=3593183&FileName=VA256-17-N-0915-000.docx)
- Record
- SN04550271-W 20170621/170619235957-0004f3aa549d2a094f320db0cb0017e9 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |