SOURCES SOUGHT
65 -- Leica Lab automated microtome tissue cutter
- Notice Date
- 6/20/2017
- Notice Type
- Synopsis
- NAICS
- 334516
— Analytical Laboratory Instrument Manufacturing
- Contracting Office
- Department of Veterans Affairs;Overton Brooks VA Medical Center (90C);510 East Stoner Avenue;Shreveport LA 71101
- ZIP Code
- 71101
- Solicitation Number
- VA25617N0919
- Response Due
- 6/27/2017
- Archive Date
- 7/27/2017
- Point of Contact
- Veronica Maskell
- Small Business Set-Aside
- N/A
- Description
- DEPARTMENT OF VETERANS AFFAIRS VETERANS INTEGRATED SERVICE NETWORK (VISN) 16 OVERTON BROOKS VETERAN AFFAIRS MEDICAL CENTER (OBVAMC), SHREVEPORT, LA REQUEST FOR INFORMATION VA256-17-N-0919 BACKGROUND: The Shreveport OBVAMC has a requirement for the following brand name supplies: The purchase, delivery, installation and set up of a Leica Biosystems automated microtome. Manufacturer Stock# Description Leica Biosystems 1492255UL01 Leica RM2255 - Configuration 1 Leica Biosystems 14050238257 Foot Switch for RM2255 Leica Biosystems 14041136960 Power Cord USA Angle Bent Leica Biosystems 9CONSLVRRM2255 Additional Year Service/Warranty for RM2255 Physical Characteristics Leica RM2255 - Configuration 1 Technical specifications: Trimming thickness range and increments: 1-600 µm 1-10 µm in 1- µm increments 10-20 µm in 2- µm increments 20-50 µm in 5- µm increments 50-100 µm in 10- µm increments 100-600 µm in 50- µm increments Section thickness range: 0.5 - 100 µm Section thickness increments: 0.5-5 µm in 0.5- µm increments 5-20 µm in 1- µm increments 20-60 µm in 5- µm increments 60-100 µm in 10- µm increments Dimensions: Width: 300 mm / 11.81 inches (excl. handwheel) 413 mm / 16.26 inches (incl. handwheel) Depth: 618 mm / 24.33 inches (incl. section waste tray) Height: 305 mm / 12.01 inches Weight: approx. 40 kg / 88.11 lbs Admissions: CE, c-CSA-us Voltage: adjustable via voltage selector Operating temperature range: + 10 °C up to +35 °C Relative air humidity: max. 80 %, non-condensing Delivery Location: Alexandria VAMC Building 7, 3rd Floor Main Laboratory 2495 Shreveport Highway 71 Pineville, LA 71306 REQUESTED RESPONSES: The intent of this Request for Information is to establish sources in order to define the procurement strategy. Interested contractors are requested to respond in accordance with the following Please respond to this RFI if you are capable of providing the brand name products listed in the table found in the background section above. In the response please cite business size status. Please respond to this RFI if you are capable of providing supplies that can be determined EQUIVALENT to the products listed in the table found in the background section above. Please provide details on proposed EQUIVALENT products such as Manufacturer Name, Part Number, and Description. CONTACT INFORMATION AND RESPONSE DUE DATE: Please email all responses to veronica.maskell@va.gov. Please respond to this RFI no later than 12:00pm Central on Tuesday, June 27, 2017. DISCLAIMER: This RFI is issued solely for informational and planning purposes and does not constitute a solicitation. Responses to this notice are not offers and cannot be accepted by the Department of Veterans Affairs to form a binding contract. Respondents are solely responsible for all expenses associated with responding to this RFI. NOTE: THIS NOTICE WAS NOT POSTED TO FEDBIZOPPS ON THE DATE INDICATED IN THE NOTICE ITSELF (20-JUN-2017); HOWEVER, IT DID APPEAR IN THE FEDBIZOPPS FTP FEED ON THIS DATE. PLEASE CONTACT 877-472-3779 or fbo.support@gsa.gov REGARDING THIS ISSUE.
- Web Link
-
Link To Document
(https://www.fbo.gov/spg/VA/ShVAMC/VAMCLAOBrooks/VA25617N0919/listing.html)
- Place of Performance
- Address: Alexandria VAMC;Building 7, 3rd Floor Main Laboratory;2495 Shreveport Highway 71;Pineville, LA
- Zip Code: 71306
- Country: USA
- Zip Code: 71306
- Record
- SN04550730-F 20170622/170620234301 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |