Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY - FEDBIZOPPS ISSUE OF JUNE 24, 2017 FBO #5692
SOURCES SOUGHT

J -- JBSA Randolph Hangar Fire Suppression - Draft PWS

Notice Date
6/22/2017
 
Notice Type
Sources Sought
 
NAICS
811310 — Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance
 
Contracting Office
Department of the Air Force, Air Education and Training Command, 502d Contracting Squadron, 1655 Selfridge Avenue, JBSA Lackland, Texas, 78236-5253, United States
 
ZIP Code
78236-5253
 
Solicitation Number
JBKAAB2017
 
Archive Date
7/12/2017
 
Point of Contact
Shantana S. Davis, Phone: 2106711734
 
E-Mail Address
shantana.davis.1@us.af.mil
(shantana.davis.1@us.af.mil)
 
Small Business Set-Aside
Woman Owned Small Business
 
Description
Draft PWS Please see attached Draft Performance Work Statement (PWS). This is a sources sought synopsis only, (not a pre-solicitation notice pursuant to FAR Part 5). This survey is to determine the capability of potential sources and the availability of commercial sources and services pursuant to FAR Part 10, Market Research. The purpose of this notice is to gain knowledge of potential qualified sources and is neither a request for quotes nor a solicitation of offers. Information received will be considered solely for the purpose of determining whether conducting a competitive procurement is possible for the Government. Responses must provide clear and concise documentation indicating a vendor's bona fide capability to provide this equipment/service. The respondent must provide a Capability Statement that addresses the organization's qualifications and ability to support and perform as a prime contractor, the work described below. Include a brief resume of performance of similar services of the magnitude described below (include contact and phone number of projects listed), and a sample Quality Control Plan. Responses should contain Company Name, Address, Point of Contact, Cage Code, Phone Number, Email address, a statement as to whether your company is domestic or foreign owned, and Size of Business pursuant to NAICS code 811310, business size standard $7.5M. DESCRIPTION: The contractor shall provide all personnel, supplies, equipment, tools, materials, supervision, transportation, and other items and services necessary to perform all requirements in accordance with this Performance Work Statement (PWS). Contractor shall perform inspections, testing and maintenance on drainage discharge gates next to hangars 40/42, building 50 fire pumps/diesel engines, building 51 storage tank and fire suppression systems, alarms, and components in hangars Joint Base San Antonio (JBSA) Randolph (RAN) facilities 40, 41, 42, 44, 82, 83, and JBSA-Lackland (LAK) facilities 826, 829, 935, and 946 established in Appendixes A and B. Contractor shall be licensed to perform inspection, testing, and maintenance requirements on an Aqueous Film Forming Foam (AFFF), High Expansion Foam (HEF), wet-pipe fire protection, Fire Alarm Control Panels and backflow devices. Contractor shall be certified to test and report diesel engine emissions. Contractor shall perform all contract requirements in accordance with the most current edition of all applicable Federal, State, local, Department of Defense (DOD) and Air Force regulations, including, but not limited to the Unified Facilities Criteria (UFC) 3-601-02, National Fire Protection Association (NFPA) 25, NFPA standard 409, for Aircraft hangars and Government provided specifications/requirement data. ESTIMATED CONTRACT DURATION: Five ordering years. SYSTEM LOCATIONS: The contractor shall perform inspections, testing, maintenance and reporting at JBSA-RAN buildings/hangars 40, 41, 42, 44, 50, 51, 82, 83, and at JBSA-LAK in buildings/hangars 820, 826, 829, 935, and 946, in accordance with UFC 3-601-02 tables and manufacturer specifications established in Appendixes A and B. All information submitted should fully support the vendor's definite capability to provide the supplies/service required, and shall be furnished at no cost or obligation to the Government. Verbal responses are not acceptable and cannot be considered. Any interested party requiring additional information may inquire with the below point of contact. This notice is for informational purposes only and does not constitute an Invitation for Bid or Request for Proposal, and is not to be construed as a commitment by the Government. The Government will not reimburse contractors for any cost incurred for their participation in this survey. Interested sources should submit responses to A1C Shantana Davis, 502/JBKAA, shantana.davis.1@us.af.mil, or Mr. Jorge Canavati, 502/JBKAA, jorge.canavati@us.af.mil. For any questions contact A1C Shantana Davis at (210)671-1734 or Mr. Jorge Canavati (210)671-1728, or the emails above. Respondent will not be notified of the results of the information; however, the contracting officer will utilize the information for technical and acquisition planning. All proprietary information not to be disseminated in Government documents must be clearly identified. Since this is a sources sought announcement only, no evaluation letters and/or results will be issued to the participants. This market survey is issued to determine the applicable planning and acquisition strategy based on responses indicating capability in responding to this requirement.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/USAF/AETC/LackAFBCS/JBKAAB2017/listing.html)
 
Place of Performance
Address: Randolph/Lackland, United States
 
Record
SN04554290-W 20170624/170622235030-ae7d8d113acc7238f238934974986675 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers