Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY - FEDBIZOPPS ISSUE OF JUNE 24, 2017 FBO #5692
DOCUMENT

65 -- Humphrey Visual Field Analyzer - Attachment

Notice Date
6/22/2017
 
Notice Type
Attachment
 
NAICS
334510 — Electromedical and Electrotherapeutic Apparatus Manufacturing
 
Contracting Office
Department of Veterans Affairs;Network Contracting Office (NCO) 10;Service Area Office (SAO) Central;3140 Governor ™s Place Blvd. Suite 210;Kettering OH 45409-1337
 
ZIP Code
45409-1337
 
Solicitation Number
VA25017Q0778
 
Response Due
6/27/2017
 
Archive Date
7/27/2017
 
Point of Contact
Stacy Massey
 
E-Mail Address
8-6511x3135<br
 
Small Business Set-Aside
N/A
 
Description
This Sources Sought Notice is for informational and planning purposes only and shall not be construed as a solicitation or as an obligation or commitment by the Government. This notice is intended strictly for market research. The purpose of this Sources Sought notice is to obtain information from qualified vendors with special interest relative to the North American Industry Classification Code (NAICS) 334510, Electromedical and Electrotherapeutic Apparatus Manufacturing. Requirement Description Ophthalmology Upgrade - Humphrey Field Analyzer* - See continuation page This procurement is for new items only; no remanufactured or "gray market" items. All equipment must be covered by the manufacturer's warranty. DELIVERY LOCATION: Cincinnati VA Medical Center 3200 Vine Street Cincinnati, Ohio 45220-2213 Interested vendors are reminded that in accordance with FAR 4.12, prospective contractors shall complete electronic annual representations and certifications in conjunction with FAR 4.11 required registration in the System for Award Management (SAM) database prior to award of a contract. Registration is available at www.sam.gov. To be eligible to respond as an SDVOSB or VOSB, a firm must be Center for Veterans Enterprise (CVE) registered in VetBiz. Registration may be accomplished at http://www.vip.vetbiz.gov. Responses to this sources sought notice must contain the following information: (1) Company name and address, point of contact with phone number, and DUNS number; (2) Business type (Large, Small, Women-Owned, SDVOSB/VOSB, etc) (3) Capability statement Responses to this notice must be made via e-mail to Stacy.Massey@va.gov. Responses may be submitted as attachments, or contained in the body of the e-mail, and must be clearly marked VA250-17-Q-0778- Humphrey Field Analyzer -Sources Sought" in the subject line and document header. The deadline to respond is June 27, 2017, at 4:00 pm (Local). As a reminder, this is a Sources Sought announcement only. CONTINUATION PAGE ZEISS OS | HFA3 MODEL 860 W/ LIQUID TRIAL LENS, RELEYE, KINETIC, GPA, HEAD TRK, GAZE TRK, PRINTER & TABLE | 1/EA ****TECHNICAL SPECIFICATIONS**** Dimension: 46 L x 52 W x 58 H (cm) which is exactly equivalent to: 18.11 L x 20.47 W x 22.83 H (inch) Electrical Requirement: 100-120v- 50/60 Hz, 4.0A Internal Storage: 500 Gb Operating System: Windows 7-64 bit Fixation Control Video eye monitor Heijl-Krakau blind spot monitor Gaze Tracking Head Tracking Vertex Monitoring Visual Field Index : Summary measurement of the patient s visual field status, expressed as a percent of a normal age-adjusted visual field. Liquid Trial Lens : Using Liquid pressure, delivers each patient s refractive correction. Available correction range is -8 to +8 diopters. Spherical correction only. Liquid Trial Lens available in model 860 only. SmartTouch interface: Touch screen interface allows for a more efficient workflow RelEye: The RelEYE fixation monitoring system allows for systematic and pin point fixation inspection. The HFA 3 captures and keeps the image of the eye during the testing and just after, prior to the Result Review Screen. RelEYE cannot be viewed on the HFA 3 after terminating the test. Using the HFA 3, RelEYE is also available in FORUM Glaucoma Workplace (minimum version 2.0.3). Only FORUM can keep the RelEYE data stored for future usage for exporting exams. Guided Progression Analysis (GPA ): GPA allows the doctor to compare visual field status and progression to data collected from glaucoma subjects. GPA provides statistically significant change as well as rate of change, and predict future vision quality. Connectivity: For comprehensive connectivity the HFA 3 can be connected to FORUM (minimum version 3.2) with FORUM Glaucoma Workplace (minimum version 2.0.3). DICOM conformant as per the DICOM Conformant Statement, available at http://www.zeiss.com/meditec/en_us/products---solutions/ophthalmology-optometry/dicom.html HFA 3 also supports common file folder sharing used by most Electronic Medical Record Systems (EMR). SITATM (Swedish Interactive Threshold Algorithm): A patented algorithm for fast and accurate visual field threshold measurements; it is the most commonly used test strategy and incorporates patient responses in real time. SITA database: The SITA normative database contains normative data for SITA Standard and SITA Fast 30-2, 24-2 and 10-2 threshold visual field test results from healthy subjects aged 17 to 89. SITA-SWAP / Blue-Yellow Perimetry: Replaces the Full Threshold and FastPac strategies for testing SWAP visual fields due to the much shorter test times available when utilizing SITA SWAP STATPAC : It is a software package using normative values and patient data to perform statistically analysis to help interpret test data. STATPAC is the software, normative data and statistical analysis in HFA. Kinetic Testing: In kinetic testing, light stimulus of fixed characteristics is moved into the visual field from a non-seeing area, until it is detected by the patient. Typically, the stimulus is brought toward the center from several directions and the operator marks the location at which the patient first detects the stimulus (threshold point). The HFA 3 provides a kinetic graphical interface with full 180 º testing range. Glaucoma Hemifield Test (GHT): Compares points in the superior and inferior hemifield to provide analysis of test results. On 24-2 and 30-2 tests, the GHT evaluates five zones in the superior field and compares these zones to their mirrored zones in the inferior field. The GHT evaluates the severity of disturbed points in each zone pair, relative to its normal database. Legacy data: patient legacy data can be transferred from the HFA II and HFA II-i to the HFA 3. FORUM Glaucoma Workplace (minimum version 2.0.3): Allows to review quantitative and qualitative information from all standard HFA analyses; change baseline and capture, track and measure progression with G
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/VA/DaVAMC552/DaVAMC552/VA25017Q0778/listing.html)
 
Document(s)
Attachment
 
File Name: VA250-17-Q-0778 VA250-17-Q-0778.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=3605281&FileName=VA250-17-Q-0778-000.docx)
Link: https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=3605281&FileName=VA250-17-Q-0778-000.docx

 
Note: If links are broken, refer to Point of Contact above or contact the FBO Help Desk at 877-472-3779.
 
Place of Performance
Address: Cincinnati VA Medical Center;3200 Vine Street;Cincinnati, OH
Zip Code: 45220-2213
 
Record
SN04554768-W 20170624/170622235350-ada7d924e4f130924eb2f8888628f646 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.