Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY - FEDBIZOPPS ISSUE OF JULY 27, 2017 FBO #5725
DOCUMENT

65 -- Promax S3 Panoramic-digital includes installation - Attachment

Notice Date
7/25/2017
 
Notice Type
Attachment
 
NAICS
339114 — Dental Equipment and Supplies Manufacturing
 
Contracting Office
Department of Veterans Affairs;Network Contracting Office 20;5115 NE 82nd Ave, Suite 102;Vancouver WA 98662
 
ZIP Code
98662
 
Solicitation Number
VA26017N0557
 
Response Due
7/27/2017
 
Archive Date
11/3/2017
 
Point of Contact
Lorna Craig
 
Small Business Set-Aside
Service-Disabled Veteran-Owned Small Business
 
Description
The Department of Veterans Affairs, VISN 20 Network Contracting Office (NCO) is conducting Market Research on behalf of Spokane VA Medical Center through this sources sought to help determine the availability of qualified Service Disabled Veteran Owned Small Businesses (SDVOSB), Veteran Owned Small Businesses (VOSB) and Small Businesses to provide panoramic-digital equipment that meet the below requirements: PROMAX S3 Panoramic-digital with cooling fan to Includes physical installation of Planmeca Promax equipment to prepared site based on pre-installation instructions provided. Planmeca does not install supports, electric or pull cables. It must also be compatible with our current imaging systems (MiPACS and Dicom) and have CT upgradability (3D imaging). Standard panoramic, lateral TMJ (closed and open), PA TMJ (closed & open, PA sinus, child mode. Generator Constant potential, resonance mode high frequency 80 150 kHz X-ray tube D-054SB-P Focal spot size 0.5 x 0.5 mm (IEC 336) Total filtration min. 2.5 mm Al equivalent Anode voltage 50 84 kV Anode current 0.5 16 mA DC Exposure time Pan 2.7 16 s Scanning ceph 6.6 9.9 s Planmeca ProCeph 0.1 0.8 s Tomo 3 s / frame SID Pan 500 mm (19 in.) Ceph 163 170 cm (64 67 in.) Magnification Pan constant 1.2 Ceph 1.08 1.13 CCD pixel size 48 µm Image pixel size 48/96/144 µm selectable CCD active surface Pan 6 x 147 mm Ceph 6 x 295 mm Resolution (digital) Pan max. 9 lp/mm Ceph max. 5.7 lp/mm Line voltage 100 240 V, 50 or 60 Hz Regulation Automatic, ±10 % Line current 8 16 A In the response, identify if contractor is SDVOSB, VOSB, or Small Business. This is for information only. Do not send a price quote. If the contractor can provide the above items, the contractor shall provide a letter from the manufacturer stating they are an authorized distributor for their products. Failure to submit an authorized distributor letter shall result in the product(s) potentially offered to be considered grey market and shall not be considered technically acceptable. The capability statements received from this market research are for planning purposes only and will assist the Government in planning its acquisition strategy. This is strictly market research and the Government will not entertain questions concerning this market research. The Government will not assume any costs incurred by the contractor in the preparation of responses. All responses shall be submitted in writing no later than July 27th, 12:00 PM, PST to the attention of: Lorna Craig E-mail address: lorna.craig@va.gov
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/notices/46f887ea410b33888b85dc93028fa77d)
 
Document(s)
Attachment
 
File Name: VA260-17-N-0557 VA260-17-N-0557.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=3685711&FileName=VA260-17-N-0557-000.docx)
Link: https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=3685711&FileName=VA260-17-N-0557-000.docx

 
Note: If links are broken, refer to Point of Contact above or contact the FBO Help Desk at 877-472-3779.
 
Place of Performance
Address: Spokane VA Medical Center;Mann-Grandstaff VA Medical Center;4815 N. Assembly St.;Spokane, WA
Zip Code: 99205
 
Record
SN04596354-W 20170727/170726042523-46f887ea410b33888b85dc93028fa77d (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.