Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY - FEDBIZOPPS ISSUE OF JULY 27, 2017 FBO #5725
DOCUMENT

65 -- Sources Sought - Ophthalmological Visualization System - Attachment

Notice Date
7/25/2017
 
Notice Type
Attachment
 
NAICS
339115 — Ophthalmic Goods Manufacturing
 
Contracting Office
Department of Veterans Affairs;Great Lakes Acquisition Center (GLAC);115 S 84th Street, Suite 101; WI 53214-1476
 
ZIP Code
53214-1476
 
Solicitation Number
VA69D17N1450
 
Response Due
8/1/2017
 
Archive Date
8/16/2017
 
Point of Contact
Jim Hedman
 
Small Business Set-Aside
N/A
 
Description
This Sources Sought Notice is for informational and planning purposes only and shall not be construed as a solicitation or as an obligation or commitment by the Government at this time. This notice is intended strictly for market research. The purpose of this Sources Sought notice is to determine interest and capability of VIP-Verified Veteran-Owned Small Business (VOSB) and Service-Disabled Veteran-Owned Small Business (SDVOSB) prospective contractors relative to the North American Industry Classification System (NAICS) Code 339115 (Ophthalmic Goods Manufacturing). The Carl Zeiss Meditec, Inc. ZEISS OPMI PENTERO 900 Ophthalmological Visualization System is known to meet the Government s needs. The Government is requesting that responsible VOSB or SDVOSB sources respond if it can provide the following items on a brand name or equal basis: Line Item Item Number Description Quantity Unit 0001 302582-9902-000 CARL ZEISS MEDITEC, INC. | OPMI PENTERO 900 1 EA 0002 000000-1055-278 CARL ZEISS MEDITEC, INC. | DUSTCOVER BLUE 1 EA 0003 302581-9200-000 CARL ZEISS MEDITEC, INC. | ANGLED OPTICS WITH ROTATABLE DOVETAIL 1 EA 0004 000000-0576-392 ZEISS MS | USB 3.0 MEMORY STICK 64GB 1 EA 0005 000000-0574-996 ZEISS MS | External Mini Harddisk 1TB USB3.0 1 EA 0006 000000-0457-982 CARL ZEISS MEDITEC, INC. | VIDEO CONNECTING CABLE Y/C OUT, 10M 1 EA 0007 305989-8764-000 CARL ZEISS MEDITEC, INC. | HD-SDI-VIDEOCABLE 75 OHM 2X BNC 10M 1 EA 0008 000000-0522-961 CARL ZEISS MEDITEC, INC. | NETWORK CABLE CAT.6 BLACK 10M 1 EA 0009 305989-8609-000 CARL ZEISS MEDITEC, INC. | ROCKER SWITCH, 2 FUNCTIONS, 3 M CABLE 1 EA 0010 306026-0000-000 CARL ZEISS MEDITEC, INC. | ZEISS STERILE DRAPES, TYPE 26, PACK OF 5 1 EA 0011 302582-9810-000 CARL ZEISS MEDITEC, INC. | UPGRADE LICENCE IOF / DICOM PENTERO 900 1 EA 0012 302582-9811-000 CARL ZEISS MEDITEC, INC. | LICENCE MULTIVISION PENTERO 900 1 EA 0013 302582-9812-000 CARL ZEISS MEDITEC, INC. | LICENCE AUTOFOCUS/AUTODRAPE PENTERO 900 1 EA 0014 302581-9764-000 CARL ZEISS MEDITEC, INC. | HIGH DEFINITION CAMERA 3-CHIP NTSC 1 EA 0015 302582-9700-000 CARL ZEISS MEDITEC, INC. | INTEGRATED HD VIDEORECORDING SYSTEM 1 EA 0016 303791-0000-000 CARL ZEISS MEDITEC, INC. | 180 ° TILTABLE TUBE 2 EA 0017 305542-0000-000 CARL ZEISS MEDITEC, INC. | WIDEFIELD, PUSH-IN EYEPIECE 10X 6 EA 0018 303771-9020-000 CARL ZEISS MEDITEC, INC. | FOLDABLE TUBE F170/F260 1 EA 0019 000000-1063-869 CARL ZEISS MEDITEC, INC. | STEREO CO-OBSERVATION TUBE W/ TWO JOINTS 1 EA 0020 302582-9101-000 CARL ZEISS MEDITEC, INC. | SHIPPING CRATE OPMI PENTERO 1 EA Salient Characteristics (The Carl Zeiss Meditec, Inc. ZEISS OPMI PENTERO 900 Ophthalmological Visualization System or EQUAL): One (1) Carl Zeiss OPMI Pentero 900 or EQUAL Motorized focus with minimum working distance of 200-500 mm Motorized zoom with minimum 1:6 zoom ratio Xenon light source minimum 2 x 300 watt Utilize automatic Iris control for adjusting illumination on to the field of view to prevent inadvertent light exposure Encompass individual light threshold setting Utilize focus light link to control light intensity from working distance Display life time remaining of illumination lamp. Ability to configure system via touchscreen, handgrip, or footswtich Utilize magnetic clutches across all system axes Utilize a central user interface for accessibility Utilize a variable speed XY movement in 3 axes Utilize autobalance to automatically balance the scope for fast system set-up. Utilize an autodrape feature to automatically evacuate air for the sterile drape without obstruction to scope s mobility HD video touchscreen minimum 22 inch SD Video input for external video sources Minimally offer BLUE 400, Infrared 800 and Yellow 560 Intraoperative fluorescence capability or equivalent Maximum System Weight (including all accessories) 365 kg Maximum occupied footprint of 736 mm x 736 mm for base Must utilize medical grade casters for transport One (1) Dustcover Blue One (1) Angled Optics with rotatable dovetail One (1) USB Memory Stick Utilize 3.0 USB b. Minimal 64GB storage One (1) External Hard disk Utilize USB 3.0 Minimal 1TB storage One (1) Video connecting cable S-video Minimal 10 meters in length One (1) HD-SDI Video cable BNC connections Minimal 10 meters in length One (1) Network Cable Cat 6 cable Minimal 10 meters in length Five (5) Sterile drapes One (1) DICOM upgrade license for surgical scope System must have an approved DICOM module for storage to local Vault stream or Forum servers One (1) Software License One (1) AutoFocus/Autodrape license One (1) High definition camera Integrated 3-CMOS SD video One (1) Integrated HD Video recording system Capable of capturing still images and storing to HDD or external USB drive Capable of recording and editing HD or SD video Two (2) 180 degree tiltable tube Six (6) Widefield, push-in eyepiece Minimum 10X zoom capability Utilize magnetic attachments or equivalent for quick changeability 18. One (1) Foldable Tube F170/F260 Foldable eye tube to increase positioning capability beyond fixed eye tubes Utilize a quick dial turn to provide minimal magnification gain of 50% One (1) Stereo Co-observation Tube with TWC joints Must provide minimum of one year warranty to include parts/labor commencing on date of installation. Interested VOSBs and SDVOSBs are required to submit an e-mail delineating: Qualifications, capabilities, and experience for providing this product; Business size/Socioeconomic status; If the product is on the Federal Supply Schedule or the Open Market; and Memo or correspondence which authorizes distributor to distribute the manufacturer s products. This is not a Request for Proposal or an announcement of a solicitation and no solicitation package exists at this time. Your responses will be used solely for market research purposes of the Government. The Government will not pay for any materials provided in response to this notice and submissions will not be returned to the sender. VOSBs and SDVOSBs must be registered and verified in VIP for set-aside consideration. The applicable North American Industry Classification System (NAICS) Code for this requirement is 339115 and the small business size standard is 1,000 employees. Responses due are to be submitted by e-mail to Jim Hedman at james.hedman2@va.gov. The information requested must be received no later than 09:00 a.m. Central Daylight Time on Tuesday, August 1st, 2017.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/VA/VAGLHS/VAGLHCS/VA69D17N1450/listing.html)
 
Document(s)
Attachment
 
File Name: VA69D-17-N-1450 VA69D-17-N-1450.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=3684084&FileName=VA69D-17-N-1450-000.docx)
Link: https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=3684084&FileName=VA69D-17-N-1450-000.docx

 
Note: If links are broken, refer to Point of Contact above or contact the FBO Help Desk at 877-472-3779.
 
Record
SN04597240-W 20170727/170726043135-daec0d5cc43101959b02d6da5370320b (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.