DOCUMENT
65 -- Lab Bio Safety Cabinet - Attachment
- Notice Date
- 7/31/2017
- Notice Type
- Attachment
- NAICS
- 339112
— Surgical and Medical Instrument Manufacturing
- Contracting Office
- Department of Veterans Affairs;NETWORK 23 CONTRACTING OFFICE;708 S. Third St., Suite 200E;Minneapolis MN 55415
- ZIP Code
- 55415
- Solicitation Number
- VA26317N1005
- Response Due
- 8/7/2017
- Archive Date
- 11/14/2017
- Point of Contact
- Steven Yale
- E-Mail Address
-
Steven Yale
(steven.yale@va.gov)
- Small Business Set-Aside
- Service-Disabled Veteran-Owned Small Business
- Description
- This is a source sought announcement only. This is not a solicitation announcement. The purpose of this announcement is to gain knowledge of current market conditions relative to NAICS 339112. The Department of Veterans Affairs (DVA), Network Contracting Office 23 (NCO 23), on behalf of Iowa City VA Health Care System, Iowa City, IA. is seeking to identify any vendor capable of to provide Bishop Lab Incubators. Background: Prior to issuing a solicitation, and pursuant to the Veterans First Contracting Program, the VA is trying to ascertain if there are any qualified Service Disabled Veteran Owned Businesses (SDVOSB) or Veteran Owned Small Businesses (VOSB) with the capability of providing the below services: (Respondents are not limited to SDVOSB/VOSB concerns; the Government seeks to identify all potentially interested sources): General: 8. (FROM ATTCHAMENT 3) Functional/Performance/Specification General Equipment Name: Purifier ® Logic ®+ Class II, Type A2 Biosafety Cabinets Description & Salient Characteristics Electronically Commutated Motor (ECM) Constant Airflow Profile (CAP) Technology airflow monitoring system that communicates with the ECM to deliver the precise volume of air as required and automatically adjust as filters load without relying on airflow sensors Air-Wave Entry System* Contain-Air Negative Pressure Channel Smart-Start System that allows the user to program start up and shut down operations Night-Smart System that idles the blower when the sash is fully closed Built-in interval or elapsed timer for experiment monitoring, fluorescent light or UV light control (on models with UV light) Digital clock Removable towel catch located under work surface Bright, 90-100 footcandle, glare-free fluorescent lighting located outside the contaminated work area Five year warranty LCD information center with Filter Life Remaining bar graph, status line for alarm conditions and alerts to warn when filter life diminishes to 20% and 0% Electronic security lock (optional activation) that requires code to operate the cabinet Two electrical duplex receptacles, (single outlets on 230 volt models), located one on each side, with ground fault interruption (115 volt models) Intrinsically safe negative pressure design Fully-closing, clear 1/4" tempered safety glass sash Stainless steel inlet grille with Reserve-Air Secondary Airflow Slots Supply and exhaust 99.99% efficient HEPA filters. Contact Labconco for optional 99.999% efficient ULPA filters. Leak-tight stainless steel interior Interior-mounted, line-of-sight, full color LCD information center with easy-to-understand MyLogic OS 21.7" (54 cm) maximum sash opening height and 27.0" (69 cm) viewing height Curved inlet grille for forearm support Flush-mounted stainless steel electrical receptacle covers with dampened hinges Removable, seamless type 304 stainless steel, dished work surface with lift out knobs 10 ° Angled sash with counterbalanced, anti-racking mechanism for ease of lifting ADA-compliant touchpad control on right-hand side post for manual activation of blower, light(s), timer, electrical receptacles, audible alarm mute and menu selection Noise level < 63 dBA Heat load 990 BTU/hour (4' models) Nominal inflow velocity of 105 feet per minute (fpm) (0.5 m/sec) Nominal downflow velocity of 55 fpm (0.3 m/sec) Approximately 70% air recirculation Powder-coated steel exterior NSF International listed ETL listed CE conformity marking (230 volt models) Class 5 conditions per ISO 14644-1 and 2 (formerly Class 100) Overall depth x height: 31.2" x 61.7" (79.2 x 156.7 cm) 10' (3 m) power cord with plug All products should be ordered to arrive on or about 30 September, 2017. Any Vendor willing to offer this specific product is welcome. Responses to these sources sought must include the following information. 1. General Information of your company name, address, contact person name, phone number, fax number, e-mail address(s) and DUNS number and company website if available. 2. Socio-economic status of business (i.e. SDVOSB/VOSB) Responses to this market survey shall be e-mailed to the attention of Steven Yale, at fax number (612) 333-3792 or steven.yale@va.gov. No telephone responses will be accepted. Responses must be received no later than 3:30PM CST August 07, 2017. No solicitation document is available at this time; this notice is to acquire information only. Vendors interested in providing an offer will have to respond to a solicitation announcement that shall be published separately.
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/VA/MiVAMC618/MiVAMC618/VA26317N1005/listing.html)
- Document(s)
- Attachment
- File Name: VA263-17-N-1005 VA263-17-N-1005.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=3699720&FileName=VA263-17-N-1005-000.docx)
- Link: https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=3699720&FileName=VA263-17-N-1005-000.docx
- Note: If links are broken, refer to Point of Contact above or contact the FBO Help Desk at 877-472-3779.
- File Name: VA263-17-N-1005 VA263-17-N-1005.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=3699720&FileName=VA263-17-N-1005-000.docx)
- Record
- SN04604980-W 20170802/170731231828-28758fc9954b2eafa966852897593445 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |