Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY - FEDBIZOPPS ISSUE OF AUGUST 03, 2017 FBO #5732
DOCUMENT

65 -- 586-17-2-047-0059 Natus Neuroworks EEG SYSTEM VA256-17-AP-6114 - Attachment

Notice Date
8/1/2017
 
Notice Type
Attachment
 
NAICS
334510 — Electromedical and Electrotherapeutic Apparatus Manufacturing
 
Contracting Office
Department of Veterans Affairs;Veterans Health Administration;Network Contracting Office 16;2575 Keystone Crossing;Fayetteville AR 72703
 
ZIP Code
72703
 
Solicitation Number
VA25617Q1213
 
Response Due
8/2/2017
 
Archive Date
11/9/2017
 
Point of Contact
Dena Young
 
Small Business Set-Aside
Veteran-Owned Small Business
 
Description
3 SONNY MONTGOMERY VA MEDICAL CENTER, JACKSON, MS PURPOSE: The overall purpose is to procure one Natus Neurology Xltek Electroencephalograph (EEG) System that meets our required specifications, options, and satisfies all compatibility requirements with existing equipment in the patient treatment area, specifically, the Neurodiagnostics Laboratory. The vendor shall provide all necessary tools, interfaces, equipment/hardware, software, licenses, delivery, installation, and warranty/maintenance. DELIVERY INSTRUCTIONS: All items/products that are purchased will be delivered to the address listed below no later than 60 days after contract award. DELIVERY ADDRESS: VAMC Warehouse ATTN: Neurology Service Neurodiagnostics Laboratory (127A) 1500 E Woodrow Wilson Drive Jackson, MS 39216-5199 SUBSTITUTIONS OR ALTERNATE PRODUCTS: NONE/ NOT APPLICABLE. Natus Neurology Xltek Electroencephalograph (EEG) System must be purchased for compatibility reasons. An OR EQUAL brand or type of EEG system will not meet our requirements. SPECIFIC ITEMS TO BE PURCHASED: Item # Item Description Quantity PK 1204 EEG/Sleep Acq Desktop with IP PTZColor/BW Camera on Ergo Just Cart 1 REPORT-EDITOR MS Word Report Editor for Neuroworks/Sleepworks 1 SCOPE: The goal is to have the vendor supply one Natus Neurology Xltek Electroencephalograph (EEG) System must must be purchased for compatibility reasons. An OR EQUAL brand or type of EEG system will not meet our requirements. Vendor to be able to provide and assess the product and services needed for requirements stated herein. SPECIFICATIONS: Product Compatibility Fully compatible our current Natus System Software Compatibility Compatible with our current Natus system SYSTEM Features Desktop or laptop-based acquisition stations Microsoft SQL ® Server database enabling quick and efficient data retrieval Integrated Spike & Event detection and trending for efficient data review Capability of running EEG and PSG tethered or untethered studies Synchronized HD video recording and playback Simple annotation entry Easy archiving to a network device or any type of recordable media Integrated photic stimulator Amplifier Features Compact (4 x 6 x 1 in) and lightweight (0.66 lb) Ultra low noise with superb signal quality Ample referential, differential and DC channels Integrated Oximetry channels Wireless synchronization with HD video Fast upload of ambulatory data allowing quick turnaround Battery indicator LEDs Automatic study recording after battery replacement Synchronized patient event marker Analog Specifications-AC Channels Referential Channels......................................................................................................24 Differential Channels.......................................................................................................4 Maximum Differential AC Input Before Clipping (Referential)....................20 mV pk-to-pk Maximum Differential AC Input Before Clipping (Differential)...................20 mV pk-to-pk Common Mode Rejection Ratio.............................................................. -113 dB @ 60 Hz DC Removal........................................................................................................ ±500 mV Common Mode Input Impedance...................................................................> 10 MOhms Input Noise (peak to peak).......................................................................................6.4 V Input Noise (RMS)................................................................................................. 1.08 V Input Bias Current................................................................................................. < 10 pA Channel Crosstalk....................................................................................................-56 dB Electrode Connections (including common input)...............................................Touchproof Digital Specifications Sampling Resolution Referential Channels.............................................................. 16 bits Sampling Resolution Differential Channels............................................................. 16 bits Sampling Resolution DC Channels.......................................................................... 16 bits Analog Specifications DC Channels (patient side)............................................................................ 4 non-isolated DC Input Range......................................................................................................... ± 5 V Modes of Operation Impedance (kOhm)............................................................................. <2.5, <5, <10, <25 Channel Test Signal........................................................................... Software Controllable Square................................................................................ 0.25-1 Hz, 125 V pk-to-pk Sampling Frequency.......................................................................200 Hz, 256 Hz, 512 Hz Wireless Specifications Protocol...............................................................................................Bluetooth V2.0 EDR Operating Frequency................................................................................ 2.40 2.48 GHz Transmission Power................................................................................................20dBm Modulation................................................................................................................GFSK FCCID............................................................................................................R47F2M03GL User Interface Event Switch Connection.................................................................................. 1 on board Other Connections............................................Nonin Xpod ® Oximeter or Photic Stimulator PC Interface Direct.....................................................................................................................USB 2.0 Amplifier Mechanical Approximate Size................................................. 3.94 x 6.1 x 0.98 in / 10 x 15.5 x 2.5 cm Weight........................................................................................................ 0.56 lb / 255 g Operating Parameters Operating Environmental Limits Temperature..............................................................................................10 °C to 40 °C Humidity........................................................................................................30%-75% Atmospheric Pressure....................................................................... 700 hpA-1060 hpA Transport and Storage Temperature Range..................................................-40 °C to 70 °C Transport and Storage Humidity Range.......................10%-100%, including condensation Transport and Storage Atmospheric Pressure Range............................. 500 hPa-1060 hPa Regulatory Compliance CAN/CSA C22.2 No 601.1-M90, UL 60601-1, IEC 60601-1, IEC 60601-1-1, IEC 60601-2-26, IEC 60601-1-4, IEC 60601-1-6, IEC 60601-1-2, CISPR 11/EN 55011, FCC 47 CRF Part 15 SALIENT CHARACTERISTICS EEG systems monitor brain activity and the cameras record the patient during the procedure. This allows for diagnosis of brain disorders such as epilepsy and to design the best treatment plan. It is also capable of joining the VA intranet for storage on our server. TRAINING: INCLUDED.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/VA/FaVAMC564/FaVAMC564/VA25617Q1213/listing.html)
 
Document(s)
Attachment
 
File Name: VA256-17-Q-1213 VA256-17-Q-1213.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=3703955&FileName=VA256-17-Q-1213-000.docx)
Link: https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=3703955&FileName=VA256-17-Q-1213-000.docx

 
Note: If links are broken, refer to Point of Contact above or contact the FBO Help Desk at 877-472-3779.
 
Record
SN04606310-W 20170803/170801231724-2b348cefdc0cc73d8a48275752c6d0fd (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.