Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY - FEDBIZOPPS ISSUE OF AUGUST 03, 2017 FBO #5732
SOLICITATION NOTICE

Z -- Electrical Repair/Rehab Valley Museum Bldg, YOSE

Notice Date
8/1/2017
 
Notice Type
Presolicitation
 
NAICS
238210 — Electrical Contractors and Other Wiring Installation Contractors
 
Contracting Office
NPS, PWR - OLYM MABO 600 E. Park Avenue Port Angeles WA 98362-6757 US
 
ZIP Code
00000
 
Solicitation Number
P17PS01655
 
Response Due
9/13/2017
 
Archive Date
9/30/2017
 
Point of Contact
Fuller, Phaedra
 
Small Business Set-Aside
Total Small Business
 
Description
This is a pre-solicitation notice announcing that the National Park Service, Yosemite National Park, intends to issue a Request for Proposals for construction to remove and dispose of existing electrical panels, conduits, wiring, and associated components in the utility room and other electrical distribution locations throughout the Valley Museum/District Building (a multi-use, multi-story building). This project is being solicited and awarded as a total (100%) Small Business set-aside. The NAICS code for this solicitation is 238210 with an associated small business size standard of $15 million. The magnitude of construction for this project is between $250,000 and $500,000. This magnitude range is required in accordance with FAR 36.204 and is not the government's estimate. A single firm-fixed price construction contract will be awarded as a result of the solicitation. Solicitation number P17PS01655 will be issued as a Request for Proposals, posted to http://www.fbo.gov with a link to retrieve the solicitation form, terms-conditions (including provisions and clauses), specifications, plans/drawings, and wage rates at https://www.fedconnect.net on August 15, 2017 with a response date 30 days thereafter. PROJECT LOCATION. The project is located within Yosemite National Park at the Yosemite Valley Museum / District Building, approximately eighty (80) miles north east of the city of Merced via CA Highway 140. The park's brochure map is available on-line at the Yosemite National Park website, at this website address: https://www.nps.gov/yose/planyourvisit/maps.htm. PROJECT DESCRIPTION: The work includes (a) installing new conduit wiring, service panels, and associated electrical equipment to power current operational electrical systems and permit future electrical system expansion, (b) abandoning all obsolete, inadequate branch circuit wiring that is ground deficient and replace with new thermoplastic insulated wiring with grounding, and (c) contractor will utilize surface mounted conduit systems and perform electrical system rehabilitation work as needed to minimize disturbance of historic fabric. This electrical system rehabilitation will bring the 20,000+ square foot facility into compliance with current National Electrical Code requirements. Current code violations include NEC 250 (grounding), NEC 406.3(A) (receptacle grounding).This is a historic multiple story building that houses a public museum, exhibit room, research library, meeting rooms, and 12 multi-Divisional office spaces. All work will be performed by a licensed contractor. SITE VISIT. An organized site will be scheduled for all interested parties at a time and date to be announced in the solicitation (will be in Section L of the terms-conditions attachment). Offerors are encouraged and expected to attend the scheduled site visit, to inspect the site, and to satisfy themselves regarding the conditions that may affect the cost of the products and performance. In no event shall failure to inspect the site constitute grounds for a claim after contract award. PAPER COPIES OF THE SOLICITATION WILL NOT BE ISSUED AND TELEPHONE REQUESTS, EMAIL REQUESTS, OR FAX REQUESTS FOR THE SOLICITATION WILL NOT BE ACCEPTED. The solicitation package will be posted on August 15, 2017. To receive the solicitation package (standard form and all associated attachments), click the link below for the solicitation and any amendment(s) where you'll be redirected to FedConnect at https://www.fedconnect.net. Accessing the solicitation form and attachments does not require registration in FedConnect. If clicking the link does not redirect you to the overview page in FedConnect showing the attachments on the right-side of the screen, but instead you're redirected to the FedConnect home page, then follow these step by step instructions to get to the overview page: (1) go to https://www.fedconnect.net. (2) click on "Search Public Opportunities Only." (3) select "Reference Number" from drop-down menu and type in solicitation number, and click "search." (4) Next screen will show the solicitation title as "Electrical Repair/Rehab Valley Museum Bldg, YOSE." Click the title to open the overview page. It is the responsibility of the offerors to monitor the FBO and FedConnect websites to download all amendments and attachments which may also be issued against the solicitation prior to the solicitation's closing date. ALL QUESTIONS MUST BE SUBMITTED IN WRITING VIA EMAIL (NO PHONE OR FAX QUESTIONS). Submit questions to Phaedra Fuller, Contracting Officer. Email address is phaedra_fuller@nps.gov. Please reference the solicitation number in the subject line of the email, as "P17PS01655/QUESTION." Interested parties are urged to check for amendments. The Government reserves the right to cancel this solicitation. This announcement does not constitute the solicitation.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/DOI/NPS/APC-IS/P17PS01655/listing.html)
 
Record
SN04606599-W 20170803/170801231922-629930bed2d00f2249d4936710fee3a2 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.