Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY - FEDBIZOPPS ISSUE OF AUGUST 07, 2017 FBO #5736
DOCUMENT

65 -- Lumines Selecta Duet Laser - Attachment

Notice Date
8/5/2017
 
Notice Type
Attachment
 
NAICS
333314 — Optical Instrument and Lens Manufacturing
 
Contracting Office
Department of Veterans Affairs;Network Contracting Office 2;James J. Peters VA Medical Center;130 West Kingsbridge Road;Bronx NY 10468-3904
 
ZIP Code
10468-3904
 
Solicitation Number
VA24217Q1004
 
Response Due
8/12/2017
 
Archive Date
10/11/2017
 
Point of Contact
Shari Lee
 
Small Business Set-Aside
N/A
 
Description
TITLE: 65-Sources Sought Notice SOL: VA242-17-Q-1004 DUE: August 12, 2017 by 9:00 AM EST SET ASIDE: Unrestricted at this time due to market research NAICS: 333314, Optical Instruments & Lens Manufacturing POP STATE: United States AGENCY: Department of Veterans Affairs, Manhattan VA Medical Center, 423 East 23rd Street, New York, NY 10010-5001 POC: Shari Lee; shari.lee@va.gov Mail all responses only to: Shari Lee at shari.lee@va.gov DESCRIPTION: This Sources Sought Notice is for informational and planning purposes only and shall not be construed as a solicitation or as an obligation or commitment by the Government at this time. This notice is intended strictly for market research. The purpose of this Sources Sought notice is to determine interest and capability of potential qualifications of Small Businesses Service Disabled Veteran-Owned firms relative to the North American Industry Classification Code (NAICS) 333314, Optical Instruments & Lens Manufacturing. Size Standards for this 333314 NAICS code is 500 employees. The Department of Veteran s Affairs is seeking small business manufacturers or distributors of small business manufacturers, of functionally equivalent equipment to all the following: Lumenis Selecta Duet Laser Systems The contractor shall provide all labor, equipment, supplies, materials, engineering design, and supervision to design, manufacture, and deliver this equipment. Design and delivery shall be coordinated with the Service Point of Contact Personnel, to be revealed after contract award has been determined. PHYSICAL SPECIFICATIONS: 1) Must have the minimum of the following: Combines the YAF photodistribution cababilities with the Selective Laser Trabeculoplasty (SLT) Technology into one complete unit. SLT proven laser reduces IOP without coagulating the Trabecular Meshwork. SLT laser can be safely repeated on patients; whereas most other laser cannot. Lumenis SLT technology uses a Q-switched, frequency-doubled Nd:YAG; 532 nm wavelength green laser. When applied to the target tissue, the laser is selectively absorbed by melanin-containing pigmented cells in the Trabecular Meshwork, without causing thermal or coagulative collateral damage to adjacent tissue. The increase in expression of biological cytokines and cellular mediator activities following laser irradiation recruit macrophages to the Trabecular Meshwork. In turn, macrophages remove obstructive proteins and remodel the Trabecular Meshwork, improving aqueous humor outflow and, thereby, reducing intraocular pressure (IOP). Proprietary Advanced Laser Design automatically runs internal tests to ensure that every laser pulse meets exact power requirements, and the advanced secondary control unit guarantees the power accuracy of each laser shot. The unique temperature-controlled KTP crystal ensures the continuous accuracy and stability of the 532 nm (green) laser beam. Advance component selection, laser delivery technology and enhanced slit lamp optics provide you with consistently optimal performance from this packaged platform. The Super Gaussian Beam Profile in YAG mode ensures the lowest energy level, allowing less optical breakdown, significantly lower risk of lens pitting to allow a more efficient tissue cutting that will enhance patient s safety and comfortability. Storage Space The Ergonomic Table offers true wheelchair accessibility for patients, whereas other models do not or cannot offer this feature. The Selecta table is equipped with built-in compact storage space for lenses or other accessories. Ergonomic Joystick with EZGrip Coating includes a convenient integrated laser fire-switch. The Selecta features 3 posterior defocus positions with an adjustable focal point of up to 350 m posterior to the aiming beam. The Selecta full Slit Lamp function includes a 6-step magnification changer. The Selecta table height can be easily adjusted using its electronic up/down Switch ***(1) Lumenis Inc. GAS910000 Selecta Duet w/3 years of Warranty (comes with 3 year warranty, Two procedures, one laser system. At the touch of a button, switch between Nd:Yag and SLT. Integrated SLT (532nm) and 1064nm Ophthalmic Nd:Yag Laser. Energy: 0.1 to 0.2 mJ in 0.1 mJ increments System includes: - one pair of safety spectacles - operator manual - laser safety sign. Selecta Latina Gonio Lens Designed specifically for Selective Laser Trabeculoplastry. 1.0X magnification maintains laser spot size and 1 to 1 laser energy delivery. Tilted anterior lens surface corrects astigmatism to maintain circular laser beam profile and give sharp images for examination. Suitable for standard laser trabeculoplastry. Large 63 degree mirror yields bright image for angle photography. Three year standard warranty on parts and labor from the date of installation. *** (1) Lunenis Inc. OD0200042 Co-Observe Tube W/Beamsplitter Selecta THIS IS NOT A SOLICITATION AND DOES NOT OBLIGATE THE GOVERNMENT TO ISSUE A SOLICITATION. Please be advised that the Government will not pay for any information submitted under this announcement. The applicable North American Classification System (NAICS) Code for this requirement is 333314 (Optical Instrument & Lens Manufacturing). Email should contain the following information: Name of firm, Socio-Economic category of the firm (SDVOSB), complete address, phone & fax number of contact. The email that you sent to Shari.Lee@va.gov must contain the words VA242-17-Q-1004 Lumenis Duet-Sources Sought in the subject box. **Note: All SDVOSB vendors who plan on competing for this stated acquisition must be VIP Verified at https://www.vip.vetbiz.gov/. To properly apply the VA Rule of Two 38 U.S.C. 8127 (d) Supplies and Services to procurements for SDVOSB set-asides, Contracting Officers are required to verify that all SDVOSBs who are interested parties are VIP Verified during entire acquisition process. Thank You**
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/VA/BroVANAP/VAMD/VA24217Q1004/listing.html)
 
Document(s)
Attachment
 
File Name: VA242-17-Q-1004 VA242-17-Q-1004_1.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=3714044&FileName=VA242-17-Q-1004-001.docx)
Link: https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=3714044&FileName=VA242-17-Q-1004-001.docx

 
File Name: VA242-17-Q-1004 Salient Characteristics needed.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=3714045&FileName=VA242-17-Q-1004-002.docx)
Link: https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=3714045&FileName=VA242-17-Q-1004-002.docx

 
Note: If links are broken, refer to Point of Contact above or contact the FBO Help Desk at 877-472-3779.
 
Record
SN04614693-W 20170807/170805230116-916e238a36869853bea448bc5c06e14b (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.