Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY - FEDBIZOPPS ISSUE OF AUGUST 11, 2017 FBO #5740
MODIFICATION

41 -- Environmental Control Units (ECUs)

Notice Date
8/9/2017
 
Notice Type
Modification/Amendment
 
NAICS
333415 — Air-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipment Manufacturing
 
Contracting Office
Department of the Navy, Naval Air Systems Command, Naval Air Warfare Center Aircraft Division Lakehurst, Contracts Department, Hwy. 547 Attn:B562-3C, Lakehurst, New Jersey, 08733-5083
 
ZIP Code
08733-5083
 
Solicitation Number
N68335-17-R-0094
 
Archive Date
9/22/2017
 
Point of Contact
Keith Welge, Phone: 732 323 7213
 
E-Mail Address
keith.welge@navy.mil
(keith.welge@navy.mil)
 
Small Business Set-Aside
Total Small Business
 
Description
AMENDMENT 05 All ECU Specification Control/Vendor Item Control drawings shall have the following note: "Identification of the Suggested Source(s) of Supply hereon is not to be construed as a guarantee of present of continued availability as a source of supply of the item(s)." Specification Control/Vendor Item Control drawings permit alternative sources of supply than those listed on the drawing provided the item meets the specifications detailed on the drawing. When proposing alternative source items the manufacturer's name and part number shall be provided. For Source Control Drawings, an additional source not listed will need to conform to form, fit, and function and the Offeror must provide the details and, if applicable, test results that fully indicates the proposed item is an adequate source. Additionally, the Offeror must be cognizant of and comply with ECU performance requirements as detailed in the "General Requirements and Test Specification For A/E 32C-45A Environment Control Unit" found on sheet 4 of the 1559AS400 drawing (and in the WORD DOC entitled "General Requirement and Test Specification for ECU (July2010)" found in the Data Package). Any Source Control Drawing part substitution shall not have adverse impact on ECU performance which is to be demonstrated as part of Preproduction and Individual Acceptance Testing. The Offeror must also identify the manufacturer and applicable part number for the additional source. The proposal must include information evidencing the form, fit, and function/interchangeability of the proposed substitute components, this information should be separately attached to the Technical Volume of the proposal and will not count against the 15 page limit provided in Section L of the Solicitation for the Technical Volume.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/DON/NAVAIR/N68335/N68335-17-R-0094/listing.html)
 
Place of Performance
Address: NAWCAD Contracts Department, Attn: Mr. Keith Welge, Code 2.5.2.1.1, HWY 547, BLDG 562-3, Joint Base MDL, New Jersey, 08733, United States
Zip Code: 08733
 
Record
SN04620126-W 20170811/170809232107-294f3495766d79d2156636fc3e4ff9e0 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.