DOCUMENT
65 -- Motorized Shower Chair - Attachment
- Notice Date
- 8/9/2017
- Notice Type
- Attachment
- NAICS
- 339112
— Surgical and Medical Instrument Manufacturing
- Contracting Office
- Department of Veterans Affairs;Network Contracting Office 6;100 Emancipation Drive;Hampton VA 23667
- ZIP Code
- 23667
- Solicitation Number
- VA24617N1743
- Response Due
- 8/14/2017
- Archive Date
- 9/13/2017
- Point of Contact
- Jeremy J Boston
- E-Mail Address
-
6-6003<br
- Small Business Set-Aside
- N/A
- Description
- This is a Sources Sought Notice for a Motorized Shower Chair with the below Salient Characteristics for the Asheville VAMC. Please respond if you have the ability and intent to complete this requirement. Include in your response a copy of your capabilities statement and FSS or GSA Contract Number, if applicable. This Sources Sought Notice is intended to locate any Service Disabled Veteran Owned Small Business, Veteran Owned Small Business or Small Business capable of performing this requirement. The anticipated NAICS Code for this requirement is 339112. This is not a Request for Quotation and quotes shall not be reviewed at this time. The Department of Veterans Affairs shall not be responsible for any costs incurred by the contractor as a result of this Sources Sought Notice. This notice shall not be construed as a commitment by the Government to ultimately award a contract, nor does it restrict the Government to a particular acquisition approach. All information submitted in response to this announcement is voluntary; the Government will not pay for information requested nor will it compensate any respondent for any cost incurred in developing information provided to the Government. All responses shall be submitted via email by August 14, 2017 at 4:00 PM EST. Responses shall be submitted to Jeremy Boston at Jeremy.Boston@va.gov. Phone calls shall not be accepted for this notice. Minimum Characteristics to meet the governments need: Battery Operated Shower Chair (removeable and rechargeable) Motorized up and down Moveable arms Open bottom for toileting Ability to secure patient in chair with belt over the hip feature for patient safety Locking wheels 2 batteries and charger Lifting Stroke Range 400 mm (16 ) Working Load Limit 200 kg (440 lbs) Tilt Backwards (recline) 25 degrees Tilt Forward 7 degrees Structure Powder coated, zinc plated steel and stainless steel Castors Twin Ø100 mm (4 ) castors with locking brakes Control Hand control for height adjustment and tilt Usable with sling hoists and standing/raising aids to make transfers Seat and chassis create possibilities for toileting over standard toilet or with a bed pan attached to the chair Adjustable and foldable footrest Padded seat
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/VA/HaVAMC/VAMCCO80220/VA24617N1743/listing.html)
- Document(s)
- Attachment
- File Name: VA246-17-N-1743 VA246-17-N-1743.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=3722694&FileName=VA246-17-N-1743-000.docx)
- Link: https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=3722694&FileName=VA246-17-N-1743-000.docx
- Note: If links are broken, refer to Point of Contact above or contact the FBO Help Desk at 877-472-3779.
- File Name: VA246-17-N-1743 VA246-17-N-1743.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=3722694&FileName=VA246-17-N-1743-000.docx)
- Record
- SN04620127-W 20170811/170809232107-6f1788d4577bb3b32aee4d7832fc22ce (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |