SOURCES SOUGHT
48 -- PNEUMATIC CONTROL VALVES - Statement of Work (SOW), ASME 300# Globe Style Control Valves
- Notice Date
- 8/10/2017
- Notice Type
- Sources Sought
- NAICS
- 332912
— Fluid Power Valve and Hose Fitting Manufacturing
- Contracting Office
- Department of the Air Force, Air Force Materiel Command, HQ Air Force Test Center (AFTC) - Edwards, 5 S WOLFE AVE, Edwards AFB, California, 93524-1185, United States
- ZIP Code
- 93524-1185
- Solicitation Number
- FA9300-17-PNEUMATIC
- Archive Date
- 9/2/2017
- Point of Contact
- ELLA M. MONTGOMERY, Phone: 6612770968, Patricia Hunka, Phone: 6612774503
- E-Mail Address
-
ella.montgomery@us.af.mil, patricia.hunka@us.af.mil
(ella.montgomery@us.af.mil, patricia.hunka@us.af.mil)
- Small Business Set-Aside
- N/A
- Description
- XCV-4601 DATA SHEET, RP RUN LINE ISOBYPASS, REV 3 XCV-2643 DATA SHEET, LOX RUN LINE DRAIN/VENT, REV 3 XCV-2641 DATA SHEET, RUN LINE ISOBYPASS, REV 3 XCV-2587 DATA SHEET - LOX RUN LINE DRAIN/VENT RQR SPECIFICATION 15022 - CLEANING OF COMPONENTS, PIPING, VESSELS AND RELATED ITEMS FOR OXYGEN SYSTEM SERVICE RQR COMPONENT SPECIFICATION 1004 Statement of Work (SOW), ASME 300# Globe Style Control Valves PNEUMATIC CONTROL VALVES The Air Force Test Center Specialized Contracting Division (AFTC/PZR) at Edwards Air Force Base is requesting interested vendors who can meet all the requirements for the items described in this request for information (RFI) to submit in writing a proposed part number and specification sheet for the requirement to purchase of three (3) globe vent valves for the low pressure liquid oxygen (LOX) systems and one (1) for the kerosene (RP) systems on test stand 2A. The valve will be delivered with three (3) complete rebuild kits for each valve (totaling 12 kits), which will sustain components through all test campaigns projected for Hydrocarbon Boost. The vendor will provide the components in compliance with the attached statement of work, specifications, and data sheets. The valves will enables four program test campaigns through 2021. To meet the mission requirement, the control valves must be in compliance with AFRL specifications: RQR 1004, for control valves, valve data sheets, and will be precision cleaned to level 300A. The valves are y-pattern globe valve, with a minimum flow coefficients, turndown ratios and a maximum full open to command full close actuation time, all of which are specified in supplied data sheets among other critical requirements. Further details on performance and interfaces can be found in the attached specifications, RQR 1004, for control and remote operated valves. There must be compatibility with existing hardware and technician skillsets on test stand 2A. Details for the control valves and three (3) spare soft goods kits are as follows: Item 1 1 each control valve for LOX (Liquid Oxygen) Run line drain/vent, XCV 2587 SS Main valve Body and Trim Inlet & Outlet: 3" 300# Raised Face ANSI Flanges LOX Compatible Seat and Soft Goods (important for test stand flexibility and cross-compatibility of parts) 500 PSID Sizing Delta-P Cleaned to IEST-STD-CC1246E, Level 300A Non-destructive examination (NDE) Report on Welded Inlet, Hydrostatic Test Report, Certificate of cleanliness (C of C) Item 2 1 each control valve for run iso/bypass, XCV 2641 SS Main valve Body and Trim Inlet & Outlet: 1" female boss connection AS5202 LOX Compatible Seat and Soft Goods 500 PSID Sizing Delta-P Cleaned to IEST-STD-CC1246E, Level 300A NDE Report on Welded Inlet, Hydrostatic Test Report, C of C Item 3 1 each control valve for LOX (Liquid Oxygen) Run line drain/vent, XCV 2643 SS Main valve Body and Trim Inlet & Outlet: 3" 300# Raised Face ANSI Flanges LOX Compatible Seat and Soft Goods (important for test stand flexibility and cross-compatibility of parts) 500 PSID Sizing Delta-P Cleaned to IEST-STD-CC1246E, Level 300A NDE Report on Welded Inlet, Hydrostatic Test Report, C of C Item 4 1 each control valve for RP (rocket propellant) Run line iso/bypass, XCV 4601 SS Main valve Body and Trim Inlet & Outlet: 1" female boss connection AS5202 LOX Compatible Seat and Soft Goods (important for test stand flexibility and cross-compatibility of parts) 500 PSID Sizing Delta-P Cleaned to IEST-STD-CC1246E, Level 300 NDE Report on Welded Inlet, Hydrostatic Test Report, C of C Three (3) Spare Soft Good Kits for Item 1 Cleaned to Level 300A C of C Three (3) Spare Soft Goods Kits for Item 2 Cleaned to Level 300A C of C Three (3) Spare Soft Goods Kits for Item 3 Cleaned to Level 300A C of C Three (3) Spare Soft Goods Kits for Item 4 Cleaned to Level 300 C of C Four (4) complete sets of bound maintenance manuals with valve tag numbers and contractor's serial numbers. Offers must meet the specifications included in this RFI. Include Cage Code and Size of Business in the submission. Offers are to be received by this RFI NLT Friday, 18 Aug 17. Please send a copy of your submission to the following points of contact: Ella Montgomery Contract Specialist Phone: (661) 277-0968 Email: ella.montgomery@us.af.mil Patricia L. Hunka Contracting Officer Phone: (661) 277-4503 Email: patricia.hunka@us.af.mil 2nd Lt John Bowerman Technical POC Phone: 661-275-4798 Email: john.bowerman@us.af.mil
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/USAF/AFMC/AFFTC/FA9300-17-PNEUMATIC/listing.html)
- Place of Performance
- Address: EDWARDS AFB, EDWARDS, California, 93524, United States
- Zip Code: 93524
- Zip Code: 93524
- Record
- SN04621988-W 20170812/170810231540-2836421ba716c4c6a7a5a4cb1da51b3d (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |