DOCUMENT
C -- Sources Sought - Inspection and Assessment of Firefighting Training Facilities - Attachment
- Notice Date
- 8/16/2017
- Notice Type
- Attachment
- NAICS
- 541350
— Building Inspection Services
- Contracting Office
- N39430 NAVFAC EXWC, Port Hueneme 1000 23rd AVE Port Hueneme, CA
- Solicitation Number
- N3943017R7206
- Response Due
- 9/1/2017
- Archive Date
- 9/16/2017
- Point of Contact
- William Hepler (805) 982-3872 William.hepler@navy.mil
- Small Business Set-Aside
- N/A
- Description
- This SOURCES SOUGHT ANNOUNCEMENT is a Market Survey for written information only. This is not a solicitation announcement for proposals and no contract will be awarded from this announcement. No reimbursement will be made for any costs associated with providing information in response to this announcement or any follow-up information requests. There is no bid package or solicitation. The Naval Facilities Engineering Command Engineering and Expeditionary Warfare Center (NAVFAC EXWC), Port Hueneme, CA is conducting a market survey of Architectural and Engineering firms that are capable of performing inspection, assessment, design and engineering services of Government firefighting trainer facilities at various naval installations in the United States including, but not limited to Point Loma, CA; Kings Bay, GA; Mayport, FL; Norfolk, VA and one in Yokosuka Japan. This is a NEW requirement for NAVFAC EXWC. There is no predecessor contract or incumbent. NAVFAC EXWC contemplates awarding a single award indefinite delivery indefinite quantity contract with fixed price task orders for the services listed below. Firms that choose to respond to this sources sought notice are requested to provide a brief synopsis of work that it has performed previously that is the same or similar to the requirements listed below, and the approximate number of personnel that could perform the work required. Firms are also requested to provide their small business size and status (i.e. HUBZone, SDVOSB, etc.) if applicable. The Applicable NAICS is 541350 Building Inspection Services, with a size standard of $7.5M. The Applicable Product Service Code is C213 Architect and Engineering “ General: Inspection (Non-Construction). Comments on the scope and the tentative evaluation factors are welcome. Responses of two to four pages are considered adequate to address the information being requested at this time. The tentative evaluation factors have been included as an attachment. Please note: this is not a submission requirement for this market survey. The work includes, but is not limited to: firefighting trainer inspections in accordance with NEPA 1403 Standard on Live Fire Training Evolutions; engineering analysis of existing conditions in comparison to current regulations and requirements; comparison between previous inspection reports and/or drawings of the facilities; engineering calculations for structural analysis with or without previous design calculations; documentation of findings; and generation of recommendations including cost estimates for follow-on actions. Various ASTM test methods to perform material investigation may be required. Any proposed testing methods or assumptions shall be submitted to the Government for approval. Refer to NFPA 1403 for the structural investigation of the concrete. Each inspection will include the development of a Safety Plan in accordance with ACOE EM-385-1-1 and strict adherence to all OSHA regulations and guidelines. All assessments will be performed under the auspices of a registered professional engineer (structural Engineer) with experience and expertise in refractive materials and live fire training structures per NEPA 1403Standard on Live Fire Training Evolutions. Security Requirements: Work performed will be at the SENSITIVE but UNCLASSIFIED level. The government does not anticipate the need for a security clearance; however, if clearances are subsequently required the contractor shall comply with SECNAV M5510.30, SECNAV Instruction M-5239.2, and Department of Defense (DoD) 8570.01-M. The contractor shall establish and maintain an access list of those employees working on the Contract. Estimated start date for this contract is June 2018. In accordance with DFAR 252.204-7004, to be eligible for contract award, a firm or joint venture must be registered in the Department of Defense (DoD) System for Award Management (SAM). Registration can be submitted via http://www.sam.gov. The System for Award Management (SAM) is the Official U.S. Government system that consolidated the capabilities of CCR/FedReg, ORCA, and EPLS. There is NO fee to register for this site. The A-E firm must be able to demonstrate its qualifications for the previously mentioned engineering services, including studies, design, cost estimating, troubleshooting, etc., (with respect to the published evaluation factors) to perform the following work: Investigate condition, and recommend/design corrective actions related to structure; and prepare project documentation, designs and cost estimates; perform concrete investigation. The A-E firm must be able to perform the following: 1. Field Inspection and Destructive Testing a. 100% visual inspection b. Concrete Cores from various elements for petrographic analysis c. Concrete Cores from various elements for compressive strength 2. Review of available as-built drawings. Note: Geotechnical Report may not available. 3. Site walk, photos, and field verification of as-built drawings and current condition. 4. Interview facility managers to determine information regarding the condition of the facility, recent work accomplished, and plans for facility use changes. 5. AE to perform pull tests of representative heat shield anchors to ensure they have adequate capacity to support the heat shield.. 6. Perform non-destructive testing (as deemed necessary). 7. A-e to be able to produce a final report which shall be issued and it shall include, at a minimum: a. Executive summary including: brief project description; facility key plan and photo(s); findings, general recommendations, and ROM cost estimate for retrofits based on recommendations; b. Existing building description; c. The use of the structure; d. The projected life of the structure at the current frequency of use; e. The current condition of the structure relative to the original design intent; f. Map showing locations of concrete cores g. Summary of concrete test results h. Methodology used for the inspection of the Fire Training Facility, including list or criteria; i. Results of investigation including: field observations; identification of all deficiencies (including pictures) for all structural components caused by exposure to fire, water and weather; j. Site photos including overall photographs of the structures, as well as photos of visible deficiencies; k. Conclusions and Recommendations shall describe repair schemes for all structural members found to be deficient via schematic drawings; l. Recommendations for repairs that are required to restore the structure to the original design capacities to the extent possible; m. The new projected life of the structure with the new proposed repairs and with the assumption of the same frequency of use; n. Engineering and construction cost estimates to make repairs; o. Raw data for the report inputs. 8. Notional schedule (simple bar chart key milestones). 9. AE to assume not hazardous material is in the building. 10. Visual inspection of steel framing 11. Inspection and observation of structural components and framing,
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/notices/ebcdf25b051e0a425d2161f97d097346)
- Document(s)
- Attachment
- File Name: N3943017R7206_Tentative_Evaluation_Criteria.pdf (https://www.neco.navy.mil/synopsis_file/N3943017R7206_Tentative_Evaluation_Criteria.pdf)
- Link: https://www.neco.navy.mil/synopsis_file/N3943017R7206_Tentative_Evaluation_Criteria.pdf
- Note: If links are broken, refer to Point of Contact above or contact the FBO Help Desk at 877-472-3779.
- File Name: N3943017R7206_Tentative_Evaluation_Criteria.pdf (https://www.neco.navy.mil/synopsis_file/N3943017R7206_Tentative_Evaluation_Criteria.pdf)
- Record
- SN04631061-W 20170818/170816231836-ebcdf25b051e0a425d2161f97d097346 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)