DOCUMENT
65 -- Accriva AVOXimeter 100e Co-Oximeter (VA-17-130793) Brand Name or Equal - Attachment
- Notice Date
- 8/19/2017
- Notice Type
- Attachment
- NAICS
- 339113
— Surgical Appliance and Supplies Manufacturing
- Contracting Office
- Department of Veterans Affairs;Network Contracting Office 20;5115 NE 82nd Ave, Suite 102;Vancouver WA 98662
- ZIP Code
- 98662
- Solicitation Number
- VA26017N0636
- Response Due
- 8/23/2017
- Archive Date
- 9/22/2017
- Point of Contact
- Greg Wilde
- Small Business Set-Aside
- Veteran-Owned Small Business
- Description
- The Boise VA Medical Center is seeking potential sources for the procurement of two whole blood oximeters that meet the characteristics below. Respondents should be SD/VOSBs (Service-Disabled Veteran or Veteran Owned Small Businesses) as registered in the VA s VetBiz system (www.vip.vetbiz.gov). Quotes are not being sought at this time. If your company can meet the requirements described please reply affirmatively by August 23rd 2017, 5 PM EDT, to: Greg Wilde, Veterans Health Administration, Network Contracting Office 20 Gregory.wilde1@va.gov Salient Characteristics Whole Blood Oximeter Oximeter must provide quick and accurate measurements of (ranges are minimums): Oxyhemoglobin (%HbO2) Range: 0 to 100 % Total Hemoglobin (THb) Range: 4 to 25 g/dl Oxygen Content (O2Ct) Range: 0-35 mL O2/dL Easy to use: Must have simple test method Must not require sample preparation Must use whole blood System must have at least 6 hours of operating time on battery. System must have illuminated display visible in low light Disposable Supplies Associated testing supplies must be capable of being stored at room temperature with extensive shelf life Regulatory Compliance and Data Management System must record patient and operator ID numbers, test results, date, lot numbers, and time. System must have a RS232C serial data port and can print report and transfer to RALS Web 3 data management system. System must have user-defined security features to help assure result integrity for reporting and compliance System must be able to be configured to allow use only by authorized operators and/or to allow use only if QC has been performed. System must have calibration and quality control results storage System must have quick and easy quality control
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/notices/26082953bad185307236a9b7777debf2)
- Document(s)
- Attachment
- File Name: VA260-17-N-0636 VA260-17-N-0636.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=3744905&FileName=VA260-17-N-0636-000.docx)
- Link: https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=3744905&FileName=VA260-17-N-0636-000.docx
- Note: If links are broken, refer to Point of Contact above or contact the FBO Help Desk at 877-472-3779.
- File Name: VA260-17-N-0636 VA260-17-N-0636.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=3744905&FileName=VA260-17-N-0636-000.docx)
- Record
- SN04637518-W 20170821/170819230130-26082953bad185307236a9b7777debf2 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |