Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY - FEDBIZOPPS ISSUE OF AUGUST 24, 2017 FBO #5753
DOCUMENT

65 -- CARDIAC MAPPING SYSTEM - Attachment

Notice Date
8/22/2017
 
Notice Type
Attachment
 
NAICS
334510 — Electromedical and Electrotherapeutic Apparatus Manufacturing
 
Contracting Office
Department of Veterans Affairs;Network Contracting Office 2;James J. Peters VA Medical Center;130 West Kingsbridge Road;Bronx NY 10468-3904
 
ZIP Code
10468-3904
 
Solicitation Number
VA24217Q0872
 
Response Due
8/30/2017
 
Archive Date
9/29/2017
 
Point of Contact
Paul Speedling
 
Small Business Set-Aside
Service-Disabled Veteran-Owned Small Business
 
Description
This is a COMBINED SYNOPSIS/SOLICITATION NOTICE for EnSite Velocity Cardiac Mapping System Brand Name or Equal Responses to this Combined Synopsis/Solicitation must be in writing and submitted on the attached Request for Quotation. This acquisition implements a 100% set aside for Service Disabled Veteran Owned Small Businesses (SDVOSBs). The NAICS Code is 339112; size standard is 1,000 employees. Responses to this notice shall include the following: (a) company name    b) address (c) point of contact (d) phone, fax, and email (e) DUNS number (f) Cage Code   (g) Tax ID Number (h) and must    provide a capability statement that addresses the organizations qualifications and ability  to perform as a contractor and provide the commodities described within the Request For Quotation.       Cardiac Mapping System EnSite Velocity Cardiac Mapping System Brand Name or Equal (St. Jude Medical) See Requirements/Specifications below.   The Government is not obligated to nor will it pay for or reimburse any costs associated with responding to this Combined Synopsis/Solicitation. This notice shall not be construed as a commitment by the Government to award a contract, nor does it restrict the Government to a particular acquisition approach. Notice to Potential Offerors: All Offerors who provide goods or services to the United States Federal Government must be registered in the System for Award Management (SAM located on the web at www.sam.gov). It is desirable that any Offeror to have completed their business Online Representations and Certifications Application (ORCA). Additionally, all Service Disabled Veteran Owned Small Businesses who respond to a solicitation on this project must be registered with the Department of Veterans Affairs Center for Veterans Enterprise VetBiz Registry located at http://vip.vetbiz.gov.  Requests for information and resultant responses shall be submitted directly to the contracting officer, Paul Speedling at Paul.Speedling@va.gov. NO TELEPHONE CALLS WILL BE ACCEPTED. All submissions should be received no later than 5:00 pm Eastern Standard Time on August 23, 2017. STATEMENT OF WORK Ablation equipment Introduction and Scope of Work: The Northport VA Medical Center has an active invasive cardiology and electrophysiology program. We presently refer all patients with arrhythmias that require ablation to either a local hospital or the VA Manhattan. This occurs at significant cost and inconvenience to both our patients and facility. The equipment will be installed in the cardiac catheterization laboratory at the VAMC Northport Building 200. EnSite Velocity Cardiac Mapping System Brand Name or Equal (St. Jude Medical) Requirements: The EnSite Velocity Cardiac Mapping System is a non-fluoroscopic mapping and catheter navigation system. The System creates three dimensional (3D) models that are based on the anatomy of the patient s own cardiac chamber. Cardiac electrical activity can be displayed as waveform traces or as dynamic activation or voltage maps which are superimposed on the 3D models. The navigation system displays the real time position of conventional electrophysiology catheters in relation to the 3D model. Facilitates procedures in all chambers of the heart. Features an open platform that is compatible with almost any EP catheter and most EP lab equipment. Provides real-time visualization and navigation of up to 128 electrodes on virtually any combination of catheters. The OneModel Tool enables users to create a precise model of patient cardiac anatomy in less time than previously possible. OneMap Tool, in conjunction with the OneModel Tool, allows for the simultaneous creation of the desired cardiac model and electrical map in the fewest cardiac cycles. Supports both contact and non-contact mapping procedures. Detailed model creation and a full suite of mapping tools help facilitate all popular treatment strategies. Equipment required to perform intracardiac right sided ablation and programmed electrical stimulation. System must be capable to interface with the VA s EHR (CPRS/VISTA). The system should have the ability to record and store data from the procedures and allow for report generation. Training of staff on the use of the equipment.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/VA/BroVANAP/VAMD/VA24217Q0872/listing.html)
 
Document(s)
Attachment
 
File Name: VA242-17-Q-0872 VA242-17-Q-0872_1.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=3748389&FileName=VA242-17-Q-0872-001.docx)
Link: https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=3748389&FileName=VA242-17-Q-0872-001.docx

 
Note: If links are broken, refer to Point of Contact above or contact the FBO Help Desk at 877-472-3779.
 
Place of Performance
Address: Northport;VA Medical Center;79 Middleville Rd;Northport, NY
Zip Code: 11768-2200
 
Record
SN04641333-W 20170824/170822232831-1b5b470db5c0b0a549930a6da9e3d9e4 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.